6-5. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
409
Replacement (continued)
13. Using the capillary brackets removed in step 3 (see below),
attach the capillary to the lower brackets, aligning the capil-
lary so it does NOT touch the element. (See side-view
drawing for proper installation)
Left-Front/Right-Rear
Element Side View
14. Secure the capillary to the upper brackets.
15. Replace rear cover and reconnect power to vat.
16. Lower element back into vat and close drain. Fill vat by
pressing and holding
shows in the display. Then once "1.EXPRESS FILTER"
shows in the display, press
FROM PAN" shows in the display. Press button and
"PUMP" "EXIT" shows in the display. Press button
again, and oil fi lls vat. Once vat is full, press X twice to
return to normal operation.
Model EEE-153, 154
button until *FILTER**MENU*
4 times until "5.FILL
6-6