6-5. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
6-5
Replacement (continued)
8. Using a Phillip's-head screwdriver, remove the screws
securing the capillary bulb to the upper element brackets.
9. Remove high limit bulb from element and carefully
straighten the capillary tube and pull the high limit control
from the rear of the unit.
It's important not to damage the capillary bulb when
removing or installing the high limit from the unit. Undam-
aged high limits returned for warranty can be evaluated for
cause of failure.
Capillary bulbs or tubes damaged during installation
causes high limit to fail prematurely. See damaged
capillary bulb below.
10. Insert new high limit capillary through hole in rear of fryer
and slide high limit into bracket and then secure with the 2
screws.
11. Slide bracket and high limit assembly into place, making
sure a 1/8" (2-3mm) gap remains between the red high limit
button and the reset place, and then secure with the 2 acorn
nuts removed in step 3.
12. Carefully slide capillary bulb up through the element, from
the rear of the elements.