Jib Pump; Express Filter Pc Board - Henny Penny Evolution Elite EEE-153 Technical Manual

Reduced oil capacity open fryers (split vat & full vat– electric)
Hide thumbs Also See for Evolution Elite EEE-153:
Table of Contents

Advertisement

6-14. JIB PUMP

6-15. EXPRESS FILTER PC
BOARD
6-19
This pump keeps the vats fi lled and is used in the Oil Guard-
ian™ process.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the right side panel.
2. Using a 1" wrench, loosen fi tting on right side of pump.
3. Remove the hose from the pump.
4. Remove the 4 bolts securing the bottom of pump.
5. Disconnect the wires in the rear of the pump and pull
assembly from fryer.
6. Pull fi ttings from faulty pump and attach the fi ttings to the
new pump, in the same orientation.
7. Install new pump assembly in fryer, in reverse order and
then reconnect power to fryer.
This electronic board controls the Automatic Intermittant Fil-
tering process.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Hinge-down the center control panel (right panel on 2 vat
units).
2. Pull connectors from PC board, located behind control
panel.
3. Using a 5/16" socket, remove the 6 nuts securing the board
and remove it from the fryer.
4. Install in reverse order. The control connectors are colored-
coded; Left-Red; Middle-White; Right-Blue.
Model EEE-153, 154