Main Power Switch; Temperature Probe Replacement - Henny Penny Evolution Elite EEE-153 Technical Manual

Reduced oil capacity open fryers (split vat & full vat– electric)
Hide thumbs Also See for Evolution Elite EEE-153:
Table of Contents

Advertisement

6-7. MAIN POWER SWITCH

6-8. TEMPERATURE PROBE
REPLACEMENT
409
This is a covered rocker switch, which in the ON position,
sends power to all the controls and fi lter motor.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove right side panel.
2. Label and remove wires from the switch.
3. From the inside of the control area, squeeze in on the tabs
on the back of the switch and push the switch out the front
of the control area.
Checkout
4. Check across the two sets of terminals of the switch for
continuity. With the switch in the ON position, the circuit
should be closed. With the switch in the OFF position, the
circuit should be open.
If the switch is found to be defective, replace it by connecting
the wires to it (as labeled) and push new switch into place.
The temperature probe relays the actual shortening temperature
to the control. If it becomes disabled, "E-6" shows in the
display. Also, if the temperature is out of calibration more than
10°F, or 10°C, the temperature probe should be replaced. (See
Section 5-4. TECH MODE for probe calibration steps.)
An Ohm check can be performed also. See chart at left and
Checkout instructions on next page.
Model EEE-153, 154
6-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution elite eee-154

Table of Contents