3-1. INFORMATION MODE
DETAILS (Continued)
409
6. INPUTS
Press
and "6. INPTS" and "HDE" show in displays.
H = HIGH LIMIT - If "H" is present, the high limit is good. If "-"
shows then the high limit is tripped out (overheated) or discon-
nected.
D = DRAIN SWITCH - If "D" is present, the drain handle (when
applicable) is closed. If "-" shows then the drain is open or the
switch is faulty.
E = ELEMENT SWITCH - If "E" is present, the element switch is
good. If "-" shows in the display, the element is in the upright
position, or the switch is faulty.
Press
button and an underscore ("_") indicates the input is
not presently detected. A Checkmark ("
detecting a normal input. A blinking ("X") indicates the signal is
presently detected, but is detected as a half-wave (partially failed)
input.
The H, D, E signals above are wired in series. The fi rst signal miss-
ing out of this sequence l generally causes all signals to the right of it
to be missing as well.
7. OUTPUTS
Press
and "7. OUPTS" and "S-H-" show in displays.
S = SAFETY CONTACTOR - Press
safety (primary) contactor
H = HEAT CONTACTOR - Press
.
contactor
(
turns off and on the
vat of a split vat fryer, and
8. OIL TEMPERATURE
Press
and "8.OIL TMP" shows in the left display and the
oil temperature shows in the right display.
9. CPU TEMPERATURE
Press
and "9.CPU TMP" shows in the left display and the
current PC board temperature shows in the right display.
Model EEE-153, 154
" ) indicates the signal is
to turn off and on the
to turn off and on the heat
safety (primary) contactor for the left
turns off and on the heat contactor.)