2-4. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)

2-5. POWER/PUMP SWITCH

Checkout
Oct. 2002
11. Pull all excess capillary line from the frypot and tighten nut
into frypot wall.
Be sure capillary bulb of high limit is positioned so it does
not interfere with the carrier or get damages when clean-
ing the frypot.
12. With excess capillary line pulled out, tighten smaller nut.
13. Replace front panel.
14. Refill with shortening.
The Power/Pump switch is a three-way rocker switch with a
center OFF position. With the switch in the POWER position,
the fryer operates. With the switch in the PUMP position, the
filter pump operates, but the unit will not heat.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove Control Panel.
2. Label and remove wires from the switch.
3. "OFF" Position - should be open circuit anywhere on the
switch.
4. "Power" Position. Check from:
5. "Pump" Position. Check from:
Check across the jumpers on the wires of the Power/Pump
switch. These jumpers have resistors and capacitors which
may be faulty.
2-4
Model 690
#5 to #6 closed circuit
#l to #2 closed circuit
#4 to #5 closed circuit
#3 to #2 closed circuit