UART Setting for serial device
 
 
UART0 : Reserved for the internal debugging purpose with RS232C. 
UART1 : RS485 port 
UART2 : Reserved for the communication of camera OSD control  
 
IMPORTANT : Only UART1 is available for users but UART0 and UART2 are reserved for 
internal communication purpose which are not opened to users. 
 
NOTE : The UART setting depends on the hardware version and firmware version of your 
device. The setting configuration of above is based on the hw v1.3 / firmware v1.00.06. You 
can check out the version information at [Setup] – [About] – [Version] tab of the webpage. 
 
NOTE : If you want the RS232C, please use the 485‐232 converter. 
 