Summary of Contents for Ganz H.264 Network Encoder Series

  • Page 1     IMPORTANT!  All of GANZ network camera and encoder series are using same webpage interfaces but some pages  are designed only for a specific model. The explanation and captured images at this manual are  mainly on the basis of ZN‐S1000VE, 1ch network video encoder. If you are using the GANZ encoder  or GANZ network camera models other than ZN‐S1000VE, please do not miss the additional notes at  the Section ‘6. REFERENCE TO MODELS’ of this manual. ...
  • Page 2: Table Of Contents

    GANZ Network camerab and encoder series  Webpage User's Manual   Table of Contents WHAT’S NEW ......................4 1. INTRODUCTION ...................... 6 1.1. Welcome ........................6 1.2. Getting Started ......................6 1.3. IP address setting......................6 2. USING A WEB BROWSER..................9 2.1. ActiveX Installation (AxNVC.cab)................. 9 2.2. Recommended PC specification ................10 3. MAIN PAGE CONFIGURATION................11 3.1. View page ......................... 11 4. SETUP CONFIGURATION ..................15 4.1. LOG IN ........................15 4.2. BASIC CONFIGURATION .................... 16 4.2.1. User management.....................
  • Page 3 4.8. VCA........................... 72 4.9. MOTION DETECTION ....................72 4.10. ABOUT ........................74 4.10.1. Version ........................74 4.10.2. Licenses ........................74 5. SAFETY MODE....................... 75 5.1. What is Safety Mode? ....................75 5.2. Why your GANZ encoder and network camera system boots in Safety Mode? ..75 5.3. How to recover your system from Safety Mode?............75 5.4. Limited functions under Safety Mode ............... 76 6. REFERENCE TO MODELS..................77 6.1. ZN‐S100V ........................77 6.2. ZN‐RS4000 SERIES ..................... 78 6.3. Rack for GANZ encoder ..................... 79 6.4. ZN‐D100VE........................ 80 6.5. ZN‐CS series H.264 Network  camera.................
  • Page 4: What's New

    K00.99.05  [System Log] : The configuration page is modified (No more options for number of  file)  [User] : User Authentication is modified     K00.99.08  [VCA] : Configuration page deleted  [Codec] : Q value for VBR mode is added  [View page] : Description of OSD and burnt‐in text added    K00.99.14  [VCA] : Configuration page inserted (Enabled only with license)  [NAT] : NAT page for port mapping is added  [DDNS] : Dynamic DNS is added  [UART] : Serial Over IP setting is added  [LED] : The number of LED has reduced from 4 to 2.  [AVI File Recorder] : Storage recycling option added  [AVI File Recorder] : Recording segmentation option added  [Webpage] : VIEW option for Video Contents Analysis stream is added    K1.00.04  [Video‐in] : Options for software deinterlace added    K1.00.07  [UART] : UART setting page updated per model  [RTSP/RTP] : NAL unit option is added  [RTSP/RTP] : Authentication option is added   [LED] : LED option for Heart beat is added  [TCP/IP] : Domain name for DNS configuration is not supported    K1.02.01  [SMTP] : Authentication for login is deleted  [SMTP] : SSL and TLS encryption is added  [Rack for GANZ encoder] : Rack information for multi channel solution is added  [Event Configuration] : HTTP server is added for event notifying server  [Event Configuration] : FTP server is added for event notifying server  [VCA] : Recording by VCA event triggering is added  [ZN‐DT350SERIES H.264 NETWORK DOME CAMERA] : IR Cut filter control page is deleted  2010/2‐1  03A.00    4 ...
  • Page 5 GANZ Network camerab and encoder series  Webpage User's Manual   [LED] : ‘VCA’ is removed from the list of event publisher  [UART] : SerialOverIP added more explanation      2010/2‐1  03A.00    5 ...
  • Page 6: Introduction

    GANZ Network camerab and encoder series  Webpage User's Manual   1. INTRODUCTION 1.1. Welcome This manual explains how to interface with the GANZ ENCODER AND NETWORK CAMERA series  using a standard Web browser (for example Microsoft Internet Explorer).The Web Page of the  GANZ ENCODER AND NETWORK CAMERA is implemented with protocols below.  • HTTP API – Parameter configuration commands  • RTP/RTSP – Video, Audio, and Metadata Streaming  • Active X program – Image display on client PC    NOTE:  This manual is generated based on ZN‐S1000VE, 1ch network video encoder. For all of GANZ  encoder and network camera, most of the user interfaces of web page can be applied equally.  But, inevitably some parts have been designed otherwise than ZN‐S1000VE according to the  characteristics of each model. For this reason, you should also refer to the section 6.  REFERENCE TO MODELS if you’re using multi channel solution or network camera type.  1.2. Getting Started You will need to install your GANZ ENCODER AND NETWORK CAMERA series before using this  manual. Refer to the GANZ ENCODER Hardware Manual supplied with the SDK. Once installed,  apply power to the system and refer to the ’Installation Guide’ or ‘Hardware manual’ for each  model for more detail installation guide.  1.3. IP address setting How to find the IP Address of your device:  You can figure out the default IP address of your product from MAC address. If you have  succeeded in converting the IP address like the picture below, just type the address on the  address bar of the Internet Explorer.   2010/2‐1  03A.00    6 ...
  • Page 7 GANZ Network camerab and encoder series  Webpage User's Manual   550012345 MAC 00:13:23:01:23:45 ZN-S1000VEA P1331010100000-121 MAC 00‐1C‐B8‐C0‐14‐B1 550012345 MAC Address  NVC1000A  P1331010100000-121   MAC address = 00‐1C‐B8‐C0‐14‐B1 → IP address = 192.168.35.69 Convert the Hexadecimal number to Decimal number   How to change the default IP address:  You can use ZNS‐GIT IPAdimn Tool software. It enables you to search and change the IP  address of the device. Below is the example picture of ZNS‐GIT IPAdimn Tool. Multiple GANZ  ENCODER AND NETWORK CAMERA models are searched by the ZNS‐GIT IPAdimn Tool.       What is ZNS‐GIT IPAdimn Tool?  ZNS‐GIT IPAdimn Tool helps you to search all of GANZ ENCODER AND NETWORK CAMERA  series on the network automatically and shows the product name, IP address, MAC address  2010/2‐1  03A.00    7 ...
  • Page 8 GANZ Network camerab and encoder series  Webpage User's Manual   and firmware information etc. It also enables you to change the IP address or update the  firmware. Please be fully understood about other functions and the features of ZNS‐GIT  IPAdimn Tool because the utility is essential for you to administrate the GANZ ENCODER AND  NETWORK CAMERA series easily.   2010/2‐1  03A.00    8 ...
  • Page 9: Using A Web Browser

    GANZ Network camerab and encoder series  Webpage User's Manual   2. USING A WEB BROWSER Once the Ethernet connection has been established, you have the following possibilities to see  the first image of the camera. But if it is the first time for you to access the webpage of GANZ  ENCODER AND NETWORK CAMERA series, you may face the ActiveX installation message.  2.1. ActiveX Installation (AxNVC.cab) Click “pop‐up blocked” and install the Active X control as below. You need to install ActiveX for  displaying the images.      If you have failed to install ActiveX, please follow the next step.    Delete “AxNVC” in “C:\WINDOWS\Downloaded Program Files” and connect  again to Web Page with ZNS‐GIT IPAdimn Tool or direct typing so that Active  X installer can be downloaded again.   Note   Or you can upload ActiveX (UMC.cab) manually with ZNS‐GIT IPAdimn Tool,  the IP management utility.    2010/2‐1  03A.00    9 ...
  • Page 10: Recommended Pc Specification

    GANZ Network camerab and encoder series  Webpage User's Manual   2.2. Recommended PC specification The following is the minimum and recommended PC system requirement to use a Web  browser with the GANZ ENCODER AND NETWORK CAMERA series.        Minimal  Recommended  Mainboard/Chipset  Intel 865  Intel 945P   CPU  P4 3.0GHz  Intel Core2Duo E4300  RAM  512MB  1GB  D3D support  D3D support  Nvidia, ATI,   ATI Radeon Series,   VGA  Intel built‐in graphic  Nvidia Geforce Series  Memory : 64 MB  Memory : 128 MB  Win 98, ME, 2000, XP,  OS  Windows XP SP2 or higher  Vista  Direct X   9.0    9.0   2010/2‐1  03A.00    10 ...
  • Page 11: Main Page Configuration

    GANZ Network camerab and encoder series  Webpage User's Manual   3. MAIN PAGE CONFIGURATION 3.1. View page If you have succeeded in accessing the webpage and installed the Active X without any  problem, you can find the view page of camera.    If you are asked to type the ID and Password, you can enter the default Administrator account  (case‐sensitive)    ID : root  Password : pass    NOTE :  If the image view is not shown,   1. Check out if the camera is powered on and connected properly.   2. Delete “AxNVC” in “C:\WINDOWS\Downloaded Program Files” and try to connect again to  Web Page with ZNS‐GIT IPAdimn Tool or direct URL typing so that Active X installer can be  downloaded again.     Display of debugging message on the VIEW page 1. Right‐click on the image. Then, you can see the Property and About menu.  2. Select the Property tab.    3. Go to [Video] – [OSD] menu.  4. Select the OSD text you want to display by checking the boxes.    2010/2‐1  03A.00 ...
  • Page 12 GANZ Network camerab and encoder series  Webpage User's Manual       Meaning of each OSD and menu buttons A  H  I      A : FIRST STREAM / SECOND STREAM : You can choose the stream to display on this view page.  GANZ ENCODER AND NETWORK CAMERA series support dual stream with 1 camera video  input. It enables you to use each of   streams independently for different purpose. The factory default for the first stream is  configures as MPEG with 30 FPS. The second stream is configured as MJPEG with 5 FPS as a  factory default. Go to the [Setup – Video&Audio – Codec] menu for the configuration of each  stream.    2010/2‐1  03A.00    12 ...
  • Page 13 E : SPK : If you tick this option, you can listen to the audio data captured in the camera  installed site. To enable this function, you need to connect the audio out of camera and the  audio input port of GANZ ENCODER AND NETWORK CAMERA series physically. You can  configure the detailed speaker feature at the menu of [Setup – Video&Audio – Audio].    F : MIC : If you tick this option, you can send out your voice through the microphone on your  PC. To enable this function, you need to connect the microphone with your audio input port of  your PC. You can configure the detailed microphone feature at the menu of [Setup –  Video&Audio – Audio].    G : OSD (On Screen Display) information   It shows current status of codec. To adjust the setting, go to [Setup] – [Video & Audio] –  [Codec].  Codec : H.264 ‐ Selected codec type for the image  frametype  : 720 X 480 ‐ Resolution of the image                        1001 ‐ Data size for 1 frame which is calculated by YUY2 format                         I or P ‐ Frame type shown alternatively of the moment.  dts : 1234229596.560886 ‐ The stamp showing when the image is encoded on the server. DTS  is short for Device Time Stamp. The start of the time is 00:00:00, Jan 01, 1970.   bitrate :562.648 bytes ‐  Bitrate of the image  fps : 27.000 ‐ Frame per second.   Cache for bound : 17, 25.040, ‐4.930  17 : 17 frames are waiting to be decoded on the screen  25.040 :  It shows the current speed of decoding. The normal speed should be 30 ms /fps if  the fps configuration is fixed as 30 fps. But as shown in this example, Since 17 frames and  27  frames  (currently  sensed  fps)  are  waiting  to  be  decoded;  the  decoding  is  being  processed at 25.040 ms/fps. ...
  • Page 14 GANZ Network camerab and encoder series  Webpage User's Manual   MJPEG                  20~25%  MPGE4                 around 60~65%  H.264                    around 75% ~ 80%  MD                        3%  VCA                       20% ~ 25%    e.g. Configuring MPEG for 1  channel and H.264 for 2  channel at the same time is not  allowed.    I : Date and time (Burnt‐in Text)  The time and date information are shown on the image by burnt‐in process in the GANZ  ENCODER AND NETWORK CAMERA server. These data are created before the compression of  the image and transmitted to the client PC to prevent time data from being modified.      2010/2‐1  03A.00    14 ...
  • Page 15: Setup Configuration

    GANZ Network camerab and encoder series  Webpage User's Manual   4. SETUP CONFIGURATION In Setup page you can configure the setting values of GANZ encoder series, click Setup on the  main page and you can see the menu tab on the left side of the Setup as below. A Viewer is  not allowed to enter the setup page. You will need the Operator or Administrator account for  this.   4.1. LOG IN To access the Set up configuration do the following:  1. Enter “root” and “pass” (case sensitive) in the User ID and Password (root is the  default setting for these fields)  2. Click OK    Apply and Reset At the bottom of the every page of Setup, you can see two buttons, Apply and Reset.    Apply – Send the request to NVC server and get the expected result.  Reset – Remove the typed values or settings of current page and go back to the original setting  values.  2010/2‐1  03A.00    15 ...
  • Page 16: Basic Configuration

    GANZ Network camerab and encoder series  Webpage User's Manual   4.2. BASIC CONFIGURATION 4.2.1. User management Allowed for  • VIEWER  • OPERATOR  • ADMINISTRATOR  Allowed for  • OPERATOR  • ADMINISTARTOR Administrator Operator & Administrator Administrator Operator & Administrator   Users are managed into 3 groups, viewer, operator and administrator.    Root user (ID : root, PW : pass) is authorized to control all of parts in GANZ ENCODER AND  NETWORK CAMERA management and this default user is not removable.     Limitation on user name   A user name can have from 1 up to 14 characters with alphabet and numbers.  The character range: alphabet is from a to z, A to Z and number is from 0 to 9.  Maximum of 32 accounts are available per privilege.    Limitation on password  A password can have from 1 up to 8 characters with alphabet and numbers  The character range: alphabet is from a to z, A to Z and number is from 0 to 9.  2010/2‐1  03A.00 ...
  • Page 17: User Authentication

    GANZ Network camerab and encoder series  Webpage User's Manual       User Authentication Enable – Enable the authentication step (Log‐in required for all configuration).   Option:  If you enable the ‘Enable anonymous viewer login’ box, it allows the anonymous user  access to a VIEW page only. You can remove the check if you want to request a Viewer to enter  ID and password.    Disable – Disable the authentication step (Log‐in NOT required for all configuration).  Any authentication step is not required for both of image view and setup access.    NOTE : ‘Disable of authentication’ is NOTE recommended for the security reason.     How to add a user Click the Add button and then you can see the pop‐up window as below. Type the user name  and password and select the group you want. Now you can see that the user1 is added as the  example.  2010/2‐1  03A.00    17 ...
  • Page 18 GANZ Network camerab and encoder series  Webpage User's Manual   User1 is added    How to modify a user You can modify the password and the privilege of the user. If you have forgotten the password,  you can change the password to the new one. Type the new password you want in the  Password (This password change procedure doesn’t require the old password).    Note : The user name is not allowed to be changed. If you want to modify the current user’s  name, just remove it and add a new user.  Type new password    2010/2‐1  03A.00    18 ...
  • Page 19 GANZ Network camerab and encoder series  Webpage User's Manual   How to remove a user After selecting the user name you want to remove on the User List, click the Remove button  and you can see the dialog box below. Click OK button and you can see that the removed user  is not shown on the User List anymore.  User1 is removed!    2010/2‐1  03A.00    19 ...
  • Page 20: Configuration Of Http And Https

    GANZ Network camerab and encoder series  Webpage User's Manual   4.2.2. Configuration of HTTP and HTTPS   This page enables you to set the protocol to communicate with the web server of GANZ  ENCODER AND NETWORK CAMERA. Basically, the data transmitted by HTTPS is encrypted by  SSL. GANZ ENCODER AND NETWORK CAMERA series is applied with OpenSSL. HTTPS is highly  recommended method compared to HTTP for the security reason but if you want to use HTTP,  you can check ‘Enable HTTP’ easily.     What is SSL?  It’s the abbreviation of Secure Socket Layer. SSL protects web server and makes it easy for  users to trust the contents. When you use HTTPS for communication with server, the SSL  certificate is required for the web server and the certificate enables encryption of video and  audio data during online transactions. OpenSSL is one of the data security protocols for Linux  system, which is used for the GANZ ENCODER AND NETWORK CAMERA series.    Setting the port number of web server  To communicate with server by HTTP or HTTPS with TCP, the port number can be fixed  between 1 and 65535. The factory default is set as 443.    Redirecting HTTP to HTTPS:  Even if a user tries to access server with http, you can enable the server to redirect to HTTPS.  In this case, do not set ‘80’ for port number because it can cause a conflict with HTTP port.  2010/2‐1  03A.00    20 ...
  • Page 21: Setting Date And Time Of System

    GANZ Network camerab and encoder series  Webpage User's Manual   4.2.3. Setting date and time of system Click here to  configure NTP  server    Time setting is very significant for all parts of GANZ ENCODER AND NETWORK CAMERA server  because it affects the log of streaming and burnt‐in text of video and you should be careful  when you set the time in this page. Every time you change the setting, the web server program  of GANZ ENCODER AND NETWORK CAMERA will be restarted internally (It does not reboot the  whole system).    Display of current server time   It shows the current server time with real time update.    Selecting time zone  You can choose your own time zone from the drop‐down box. If you check the ‘Automatically  adjust for daylight saving time changes,’ it allows the daylight saving time to be applied  according to your zone setting.    Setting current time of server  Select one of 3 options.  • Synchronize the server with your PC time   • Synchronize the server with NTP server  via internet  • Set the server time manually by user  Periodical time synchronization  NTP server – Server time is synchronized with NTP server. You can configure available NTP  servers at the menu [Setup – System Options – NTP]. Totally 4 of NTP servers can be added  and the first one is set as a default server (ntp1.usv.ro).  2010/2‐1  03A.00 ...
  • Page 22 GANZ Network camerab and encoder series  Webpage User's Manual   Real Time Clock on system – Server time is synchronized with Real‐time clock in the server. The  clock is attached to the board of GANZ ENCODER AND NETWORK CAMERA internally and the  clock is recharged automatically when the server is started.     Interval of synchronization  Everyday 00:00 ‐ Synchronized at every midnight  Disabled – Synchronized only when the GANZ encoder is booted newly (factory default)  2010/2‐1  03A.00    22 ...
  • Page 23: Video & Audio

    NOTE  :  This  video  input  setting  page  is  based  on  1  channel  encoder,  ZN‐S1000VE.  If  your  camera or encoder model is other than ZN‐S1000VE, move to the chapter ‘6.REFERENCE TO  MODEL’ and you can refer to the different part only from this page.      Naming of channel for camera  You can type any friendly name for the channel in case you have multiple channels with GANZ  ENCODER AND NETWORK CAMERA series. It helps you distinguish the location of cameras. Like  an example above, if you want to name the first camera as Video, just type the friendly name  as Video    NTSC or PAL  You can choose one of the video standards according to your region.     High Performance image processing  ‘Enable Deinterlace Algorithm’ enables high performance of image by merging the even fields  and odd fields  at the encoder side. If you don’t want to use this function, just uncheck the box.  • Hardware  platform  :  Processed  by  the  hardware  chip  of  GANZ  ENCODER  AND  NETWORK CAMERA board (0% of DSP is used up)  • DSP software ‐ best quality : Processed by the software of DSP (approx. 15% of DSP is  used up)  2010/2‐1  03A.00    23 ...
  • Page 24 GANZ Network camerab and encoder series  Webpage User's Manual   • DSP software‐ best performance :  Processed by the software of SDP (approx. 5% of DSP  is used up)    What is deinterlace?  When an analogue image is transferred to the GANZ ENCODER AND NETWORK CAMERA  encoding system, it comes with even fields and odd fields alternately. If you enable this option,  two fields are merged into one frame at encoder side. It helps the client application reduces  the resources of deintelacing.     NOTE  :   As the GANZ ENCODER AND NETWORK CAMERA series is DSP chip based products, the DSP  load can be essential information for users. If the load goes over 80%, it turns red. Too high of  DSP load could affect the performance of the encoder. For example, you should check out if  any factor such as too high bitrate for both of 1st stream and 2nd stream are configured or not.     Refer to the section ‘3. Main page configuration’ of this manual for more information of DSP  usage.     Setting of image attribute   Brightness, contrast, hue, saturation and sharpness are adjusted.  Brightness: The range is from 0 to 255, the default is 128.  Contrast: The range is from 0 to 255, the default is 92.  Hue: The range is from 0 to 255, the default is 128.  Saturation: The range is from 0 to 255, the default is 128.  Sharpness: The range is from 0 to 255, the default is 128.    Adjusting the location of image   When the image does not fit into the screen view, you can move the image vertically or  horizontally so that the images fit into the screen perfectly. The range is from 1 to 128 and the  default is 20 for NTSC and 25 for PAL    Using PREVIEW button  After the settings above, you can check out the display with this preview button before  applying with Apply button.  2010/2‐1  03A.00    24 ...
  • Page 25: Inserting Burnt-In Text On The Image

    GANZ Network camerab and encoder series  Webpage User's Manual   4.3.2. Inserting Burnt-in Text on the image   You can set the Burnt‐in Text for the first stream, the second stream and snapshot separately.  If you enable ‘Display graphical text before image compression,’ it allows the text to be burnt  in the image before compression. If you don’t want this function, just uncheck the box.    What is Burnt‐in Text?  When you want to display date or time on the image view, normally they are displayed on PC  monitor without the combining process with image from cameras. On the other hand, Burnt‐in  Text let the texts be burnt in the image before compression. This feature may guarantee the  accuracy of the material and allows them to be applied to reliable evidence as it’s not available  to manipulate the date and time data.    Configuration  Check or uncheck the data you want to display.    When you set the position of date, time and text, it’s recommended to use  Normalized X,Y instead of left‐top, left‐bottom, right‐top, right‐bottom.  Because the left‐top etc are just for example and if you let them fixed with  example position option, it may cause the overlap of text according to your  Note image resolution or the position of each text. To preview the position you set,    you can use the PREVIEW button.    Date format  Choose the format of the year, month and day for display.   YYYY‐MM‐DD / DD‐MM‐YYYY   2010/2‐1  03A.00    25 ...
  • Page 26 GANZ Network camerab and encoder series  Webpage User's Manual     Date position  Fix the position to display the date.  Normalized X,Y / left‐top / left‐bottom / right‐top / right‐bottom     Time format  Choose the format of the time for display.  24 HH:MN:SS / 12 HH:MN:SS    Time position  Fix the position to display the time.  Normalized X,Y / left‐top / left‐bottom / right‐top / right‐bottom     Name  Type the text you want burn. Allowed range for Name is 48 characters with alphabets,  numbers, and symbol.    Name position  Fix the position to display the name.   Normalized X,Y / left‐top / left‐bottom / right‐top / right‐bottom    Text and Outline Color  Choose the color of the text.  white and black / black and white    Transparency  Choose the transparency from 0 to 75%.  ALPHA, 0%, 25%, 50%, 75%    PREVIEW  If you click this button, it shows the image preview with the current setting.   2010/2‐1  03A.00    26 ...
  • Page 27: Codec (Video Codec, Resolution, Fps, Bit Rate Control)

    Webpage User's Manual   4.3.3. Codec (video codec, resolution, FPS, Bit rate control) Dual stream can  be configured in  separate.    Enable codec streaming  If you uncheck this box and click Apply button, you are not able to get the video stream  anymore from GANZ encoder and network camera server.    Naming of each stream  Type any friendly name to use for the stream. If you have multiple channels and streams, this  friendly name helps users distinguish each stream.    Video codec  MJPEG / MPEG4 / H.264  Image Appearance Supported resolution    NTSC  PAL  D1  720x480  720x576  VGA  640x480  640x480  QVGA  320x240  320x240  4CIF ...
  • Page 28 GANZ Network camerab and encoder series  Webpage User's Manual   Type the FPS you want.  25 fps is a maximum for PAL, 30 fps for NTSC.  JPEG Quality This quality value can be set only when the codec is MJPEG. The range is from 0 to 100 and 100  represents the best quality of MJPEG.  GOP Settings ‘P’ Frame count  GOP is an abbreviation of “Group of Pictures” and one GOP has only 1 I frame with other P  frames. Set the number of P frames here and it decides the GOP size. For example, if you have  set the P frame count as 59, then it means that GOP is 60.   Bit Rate Control VBR (Variable bit rate)  Limited ‐ It is called HVBR as well. If you set the limit of bitrate, it enables the bitrate not go  over the limited value.  Unlimited – When you set the bitrate as unlimited, it has no limitation on bitrate. It is used  when your devices have enough storage and high quality of image is required.    Q value – You can set the Q value, quantization value for the image quality when the bitrate is  set as variable bit rates.     CBR (Constant bit rate)  You can set the target bitrate from 128 to 8000 and it is used when your device has limited  storage.  2010/2‐1  03A.00    28 ...
  • Page 29: Audio (Listening, Speaking)

    GANZ Network camerab and encoder series  Webpage User's Manual   4.3.4. Audio (listening, speaking)   Listening to the audio This page helps you to set the values for capturing the analogue audio generated at the  camera installed site. After the configuration of ‘Listen’, you can listen to the sound with the  speakers of your PC. To listen to the captured sound, go to the View page and check the SPK  box. If you uncheck the box of ‘Enable capture and compression audio,’ it will disable the  server to capture the sound.    Sampling frequency  You can choose the sampling frequency.     Channel  Only mono type is provided.    Codec  You can choose the proper codec from PCM and G.711.    Volume control  The volume is adjusted from 1 and 255. The default is 128.    Talking to the speakers You can set the values for talking to the speakers directly connected to the GANZ ENCODER  AND NETWORK CAMERA server. To enable this feature you need to connect the microphone  with the audio port of your PC. If you uncheck the box of ‘Enable audio to receiving and  playback’, it disables the ‘Talk to’ feature.    2010/2‐1  03A.00   ...
  • Page 30 GANZ Network camerab and encoder series  Webpage User's Manual   NOTE : The configuration of codec and frequency of audio output is applied by the identical  setting of audio input.     TCP/IP listen port  Set the port for listening to the audio received from the remote. The default is 60000 and the  range is from 1 to 65535    Volume control  The default is 128 and the range is from 1 and 255.   2010/2‐1  03A.00    30 ...
  • Page 31: Snapshot

    GANZ Network camerab and encoder series  Webpage User's Manual   4.3.5. Snapshot   The codec format for Snapshot has no relation with the codec setting of the first stream or the  second stream because the snapshot is created on a separate stream regardless of the first  and the second one.  Be notified that only JPEG is fixed for a default codec in snapshot setting.    Using PREVIEW button  The button enables you to see the captured image     How to save the snapshot image?  Click the Preview button and right‐click on the captured image and select ‘Save picture as…’ to  save that image on your local PC     Name  Type any friendly names for multiple channels if required.    Format  Only JPEG is supported for the snapshot image.    Resolution  You can choose the resolution you want.    NTSC  PAL  D1  720x480  720x576  VGA  640x480  640x480  QVGA  320x240  320x240  4CIF  704x480  704x576  CIF ...
  • Page 32 GANZ Network camerab and encoder series  Webpage User's Manual   Quality  You can set the quality of snapshot. The range is from 0 to 100 and the default is 70.  2010/2‐1  03A.00    32 ...
  • Page 33: Event Configuration

    GANZ Network camerab and encoder series  Webpage User's Manual   4.4. EVENT CONFIGURATION NOTE : This Event setting page is based on 1 channel encoder, ZN‐S1000VE. If your camera or  encoder  model  is  other  than  ZN‐S1000VE,  move  to  the  chapter  ‘6.REFERENCE  TO  MODEL’  and you can refer to the different part only from this page.    GANZ ENCODER AND NETWORK CAMERA series is equipped with the event server program  internally and it enables you to configure the event publishers and subscribers. For instance, DI,  DO, Video loss, Motion Detection, VCA (video contents analysis), Network loss, IP change, and  health of network server can publishes the event message when an event is generated.      How to move to each subscriber setting page  Below is an example page of DI page. Click each subscriber name such as DO and you can find  that they are linked to the related setting pages. Refer to the figures of below for more specific  information.  Linked Setup ‐ IO Configuration ‐ DI/DO  Picture A Multicast setting page ( )  Picture B Multicast setting page ( )  Picture C TCP setting page ( ) ...
  • Page 34: How To Configure Each Event Server

    GANZ Network camerab and encoder series  Webpage User's Manual   4.4.1. How to configure each event server How to set the EMAIL page for sending an email  You can use Email server to get the event notification from GANZ ENCODER AND NETWORK  CAMERA and send them to the client application via email. This page helps you to configure  the Email server.  Automatically configured  according to the setting  page of [System Options –  SMTP(email)].  Type the mail receivers,  subject and contents of  email     Below is an example of received email contents when there was a video loss event.      2010/2‐1  03A.00    34 ...
  • Page 35 GANZ Network camerab and encoder series  Webpage User's Manual   How to set the Multicast server for sending an event message  You can use Multicast server to get the event notification from GANZ ENCODER AND  NETWORK CAMERA and send them to the client application. This page helps you to configure  the Multicast server.  Type a message  name to show on  event message  program  Type Address, port,  and TTL according  to your system  setting. Factory  default is 2555.      How to set the TCP server for sending an event message  You can use TCP server to get the event notification from GANZ ENCODER AND NETWORK  CAMERA and send them to the client application. This page helps you to configure the TCP  server.    Type a message  name to show on  event message  program  Type port number  according you will  use for TCP  message. Factory  default is 2555.     2010/2‐1  03A.00    35 ...
  • Page 36 GANZ Network camerab and encoder series  Webpage User's Manual   How to set the HTTP server for sending an event message  You can use HTTP server to get the event notification from GANZ ENCODER AND NETWORK  CAMERA and send them to the client application. This page helps you to configure the HTTP  server.  Type a message  name to show.  Type IP address and  port of HTTP server  default: Original message  format is shown (no parsed  data)    customer0 : Message is  shown with HTTP CGI and  parameters.  Type the desired waiting  time from HTTP server until  the response is arrived.     How to set the FTP server for sending an event message  You can use FTP server to get the event notification from GANZ ENCODER AND NETWORK  CAMERA and send them to the client application. This page helps you to configure the FTP  server.  To use FTP server, enable the  check box. And optionally, check  the text box to add text.  Type the IP address, port,  and path to save the files  Type the ID and password of  FTP server so that GANZ  ENCODER AND NETWORK  CAMERA has the privilege to  Select the file name format  you want.      2010/2‐1  03A.00   ...
  • Page 37: Assigning Event Rule To Event Publishers

    GANZ Network camerab and encoder series  Webpage User's Manual   4.4.2. Assigning event rule to event publishers Supported subscribers per each publisher: Publishers  Subscribers  DI  DO, Email, Multicast, TCP, HTTP, FTP  DO  Email, Multicast, TCP, HTTP, FTP  Video  Email, Multicast, TCP, HTTP,  Motion Detection  Email, Multicast, TCP, HTTP, FTP  VCA  DO, Email, Multicast, TCP, FTP  Network  Email, Multicast, TCP  Health  Multicast, TCP    The below is an example page of DI event configuration. For each event server setting, refer  to the section ‘4.4.1. How to configure each event server’.    When you set DI as a publisher, DO, Email, Multicast, TCP, HTTP, and FTP server can be the  subscriber of DI triggering.    Subscriber – DO  Check the DO box you want to trigger and click Apply button. For example, if you check off the  DO #1 of DI #2 => when DI #1 is detected, DO#2 will be activated. ...
  • Page 38 GANZ Network camerab and encoder series  Webpage User's Manual     Subscriber – Multicast  If you check ‘Post notification message’ and click Apply button, the server will send the  notification message via Multicast server when DI detection is occurred. Multicast server must  be configured to activate this function by clicking the link button (Multicast).    Subscriber ‐ TCP  If you check ‘Post notification message’ and click Apply button, the server will send the  notification message via TCP server when DI detection is occurred. TCP server must be  configured to activate this function by clicking the link button (TCP).    Subscriber ‐ HTTP  If you check ‘Post notification message’ and click Apply button, the server will send the  notification message via HTTP server when DI detection is occurred. HTTP server must be  configured to activate this function by clicking the link button (HTTP).    Subscriber ‐ FTP  If you check ‘Post notification message’ and click Apply button, the server will send the  notification message via FTP server when DI detection is occurred. FTP server must be  configured to activate this function by clicking the link button (FTP).    If you have finished to configure the event server and required subscribers, click Apply button  for the application.      2010/2‐1  03A.00    38 ...
  • Page 39: System Option

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5. SYSTEM OPTION 4.5.1. Setting TCP/IP (DHCP, Static IP, DNS setting)   IP Address Configuration Obtain IP address via DHCP  If you want to get your IP from DHCP server automatically, check this option and click the  Apply button. You may find the message box of below is popped up. It explains that the DHCP  server in your router device may cause a problem and fail to lease new IP address. In that case,  the latest static IP address will be applied instead. Click OK button to accept the notification.      2010/2‐1  03A.00    39 ...
  • Page 40 GANZ Network camerab and encoder series  Webpage User's Manual       Use the static IP address  If you want to use your GANZ ENCODER AND NETWORK CAMERA series with the static IP,  enable the ‘Use the following IP addresses’ and click the Apply button.    IP address: The IP address of your device  Subnet mask: The address of subnet mask of your device.   Gateway address: The gateway address of your device.   Broadcast address: It is automatically fixed by the subnet mask and IP address of your own.  For example, if you use B class (255.255.0.0) of mask, the broadcast address will be  192.168.255.255.    The test button shows if the typed IP address is occupied or not. You may find the popup  windows as below according to the availability of typed IP address.    Occupied IP  Available IP    DNS Configuration Type the IP address of DNS server you use.   2010/2‐1  03A.00    40 ...
  • Page 41: Nat Setting (Port Mapping)

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.2. NAT setting (Port mapping)   If you use the NAT router for the GANZ ENCODER AND NETWORK CAMERA network  connection, you may need to set the real IP address or domain name and port number.     1. Check the box of ‘Enable network connection via public IP address and port’.  2. Type the IP address and port number that your router uses.  3. Click Apply button (if you want to go back to previous setting, click Reset button).    When you use domain name, you should check out if the DNS or DDNS is enabled.    Go to [System Option – TCP/IP] for DNS setting.  Go to [System Option – DDNS] for DDNS setting.    NOTE: The IP address of NAT router should be designated manually.   2010/2‐1  03A.00    41 ...
  • Page 42: Setting Ntp Server

      How to use:  1. Enable ‘I am SNTP server’ of squid server and click Apply.  2. Access  the  webpage  of  the  GANZ  ENCODER  AND  NETWORK  CAMERA  which  is  supposed to be the client device of the squid server. Go to [System Options – NTP] and  type  the  IP  address  of  squid  server  on  the  ‘NTP  Server  1s’t.  (Format  example  :  192.168.11.4)  3. Click ‘Test’ button to find out if it works fine.   NOTE:  It will take about 3~4 minutes until the squid server response. ...
  • Page 43: Setting Property For Upnp

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.4. Setting property for UPnP     UPnP allows IP devices to connect seamlessly, and to simplify the implementation of networks  in remote PC environments.    Refer to the example of UPnP of Windows XP so that you can check out how the customized  settings are being applied. Find this information on your PC [Start ‐ My network places]. Find  your device, right‐click the mouse and go to [property].    e.g. Customized UPnP name and description  Friendly name Manufacturer name Model name Model description       Configuration  If you want to enable UPnP to search your device, check the box of ‘Enable UPnP’.   Friendly Name: Type any friendly name to be shown by the UPnP program. You can test it  easily with Windows as well (Start ‐ My network Places displays the devices by UPnP)    Customize Manufacturer Description  2010/2‐1  03A.00    43 ...
  • Page 44 GANZ Network camerab and encoder series  Webpage User's Manual   If you want to have your own manufacturer’s name for GANZ ENCODER AND NETWORK  CAMERA series to be shown on the UPnP program, type name and URL. Then, The UPnP  program will show the modified name and URL.     Customize Model Description  If you want to have your own model name for GANZ ENCODER AND NETWORK CAMERA series  to be shown on the UPnP program, type name, description and URL of them. Then, The UPnP  program will show the modified name, description and URL.  2010/2‐1  03A.00    44 ...
  • Page 45: Usb/Sd Storage

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.5. USB/SD Storage NOTE : This USB/SD setting page is based on 1 channel encoder, ZN‐S1000VE. If your camera  or  encoder  model  is  other  than  ZN‐S1000VE,  this  page  may  not  be  seen  according  to  your  model. Refer to the chapter 6. REFERENCE TO MODEL.  Mounted devices are shown by  clicking ‘Refresh’ button  Detail device  information by  selecting one of  items on the storage  list  Storage device Information is displayed by clicking the  ‘Select Record Device’ button  Click Apply button to use  selected device.  This page is provided to search mounted USB/SD storages device and select one of them for  data recording.  Please follow the steps described at the below. After setting this page, move  to the menu of [System Options ‐ AVI File Recorder] page and start the recording.  How to set the recording device 1.
  • Page 46 GANZ Network camerab and encoder series  Webpage User's Manual   It enables the storage device to formatting. Click the ‘Format’ button and ‘Apply’ after  selecting the storage device.    Ejecting the disk  When you want to remove the storage device safely, click the ‘Eject’ button. If the ejecting  process is done, now you can remove the memory stick from your GANZ ENCODER AND  NETWORK CAMERA device.    2010/2‐1  03A.00    46 ...
  • Page 47: Usb Wireless Lan

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.6. USB Wireless LAN NOTE : This  USB Wireless setting page is based  on  1 channel  encoder,  ZN‐S1000VE. If your  camera or encoder model is other than ZN‐S1000VE, this page may not be seen according to  your model. Refer to the chapter 6. REFERENCE TO MODELS    After the wireless LAN configuration, you can use the device in one of two modes: wired or  wireless. You cannot use the camera in both modes simultaneously. To switch between wired  and wireless modes, you have to plug or unplug the Ethernet cable. Unplugging the Ethernet  cable switches the device to wireless mode automatically.    Successful connection  Available networks list is  shown by clicking the  ‘Refresh Network List’  button  Retrieved network device  settings values are shown  by clicking the ‘Copy to  user Setting ‘button  Type the network key  value of selected AP.   Connected network  status is shown by  ‘Update Status’ button      If you are ready with the USB wireless LAN device, follow the steps below.      2010/2‐1  03A.00 ...
  • Page 48 GANZ Network camerab and encoder series  Webpage User's Manual   Step 1. Recognizing the USB wireless LAN device 1. Insert the USB wireless LAN device into the GANZ encoder and network camera.  2. After a few seconds, click the ‘Refresh Network List’ and you can see that the device is  listed on the window.   3. Click the device you want on the list. Then, the device information such as ESSID, mode,  MAC address, channel, and encryption are shown on the right side of the list window.  4. Click the ‘Copy to user setting’ button and the chosen device information is copied on  ‘Networks to connect’ section of below.  NOTE : If ‘Not connect wireless….’ message is displayed after clicking the ‘Refresh Network List’,  please check the setting of your wireless AP/router. Also make sure the USB wireless LAN card  is mounted on the unit properly.    Step2. Connecting wireless network If you have completed the recognition of the USB device for wireless LAN at the step1, you can  find that the ‘Network name, Mode, Authentication, and Encryption’ are filled automatically  according to the wireless LAN device information.    1. Type the ‘Network key’ and confirm it. The network key should be equal to the AP or  client PC you will communicate.  2. Set the Time out, Retry count, and Disable auto start referring to the explanation of  below.  Time  out  ‐  When  there’s  no  answer  from  the  server  for  time  out  seconds,  it  means  it ...
  • Page 49 GANZ Network camerab and encoder series  Webpage User's Manual   5. Disconnect the Ethernet cable from the device. Unplugging the Ethernet cable switch  the device to wireless mode automatically.    6. Wait about 30~40 seconds to switch the wireless mode.     NOTE : Switching time between wired and wireless modes may take longer than expected  according to the network connections.    NOTE : When rebooting the device with wireless mode, device’s boot time may be increased  to 4~5 minutes.    NOTE : If the wireless LAN is not connected successfully, make sure the USB wireless LAN card  is mounted on the unit properly. Click ‘Refresh Network List’ button and try to search network  devices again. Please check out the step1 and step2 again.    2010/2‐1  03A.00    49 ...
  • Page 50: Rtsp/Rtp (Multicast Or Unicast)

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.7. RTSP/RTP (multicast or unicast) Can be configured  separately by clicking  on the name, multicast  or unicast  GANZ H.264 Network camera and encoder support the multicast and unicast streaming for  both of 1  stream and 2  stream. Click the tab of MULTICAST and UNICAST as the picture  above shows and configure the RTP session as required by your network system.  RTSP Configuration To start the data streaming such as video, audio or metadata from the GANZ encoder and  network camera server, tick the box of Enable RTSP Server. If you remove the check in the box,  the streaming stops from server and the real time view is not seen on the web page.    Below is the requesting format of URL and Port for RTSP streaming. Each of IP address, port,  and session name are open to be typed by user.    2010/2‐1  03A.00    50 ...
  • Page 51 GANZ Network camerab and encoder series  Webpage User's Manual   rtsp:// rtsp server ipaddress : port / rtp session name  port : 554    e.g. rtsp://192.168.111.32:554/ch0_unicast_firststream    NAL unit option The option of “Does not include NAL unit header (Only use in ‘H.264’)” is required only when  the codec is H.264. GANZ ENCODER AND NETWORK CAMERA supports both of non‐standard  H.264 and standard.  The ‘non‐standard’ means the video stream packet includes the NAL unit  header additionally.     The factory default setting :  Non standard format  So, if you want the standard format of H.264, you should tick this option.     For your information  • NAL Stream: The stream consists of only NAL units (H.264 standard format)  • Byte Stream: The sequence identifier, NAL header, is included between NAL streams  The data structure of byte stream    …  …  … …  I  SPS  I  PPS  I IDR  I  P SLC  I P SLC  I IDR I  P SLC ...
  • Page 52 GANZ Network camerab and encoder series  Webpage User's Manual   RTSP configuration for MULTICAST NOTE : If you have decided the communication way between multicast and unicast, the option  is applied to both of first stream and second stream on the web page. BUT, each of the 1   stream and 2  stream can be configured with different way by HTTP API. Refer to the NVC  HTTP API manual.pdf in the SDK.    IP Address  In order to get the streaming data from GANZ ENCODER AND NETWORK CAMERA, you should  set the IP address of group which is used for PC to join. ‘0,0,0,0’ is configured as a factory  default and it enables router program to generate the available IP for GANZ ENCODER AND  NETWORK CAMERA automatically. If you want to use any specific address, type the address in  the blank.    NOTE : UDP/RTP multicast is not allowed for streaming even if the address and the port  information is known.     How auto configuration of IP address works?  As the session name for each RTP session is defined already on the server, your PC can get the  stream by the ‘rtsp:// rtsp server ipaddress : port / rtp session name’ without the manual  decision of IP address on the webpage.     Port  Set the port number used for router to receive the streaming data from GANZ ENCODER AND  NETWORK CAMERA (No need for unicast). ‘18888’ is set for video data of 1st stream and  ‘28888’ is for video data of 2nd stream. Refer to the ‘Ports list for GANZ ENCODER AND  NETWORK CAMERA connection’ at the end of this section4.5.6.    TTL  Set the TTL value. If you set 1 for TTL, it means the packet will pass only in a subnet (No need  for unicast).   What is TTL?  It’s the abbreviation of Time to live. If data is sent out from GANZ encoder via network and  all of the packets are alive permanently on the network, it will cause the big network load. ...
  • Page 53 GANZ Network camerab and encoder series  Webpage User's Manual   Session Description  Type the session description for more detailed information.    Include audio stream  Check this box if you want to include the audio stream as well as video stream. For your  information, video stream is the fundamental stream whenever you request the RTSP stream  as a factory default.    Include meta data  Meta data contains the motion detection and VCA (video contents analysis) data. Check this  box if you want to include the meat stream as well as video stream. For your information,  video stream is the fundamental stream whenever you request the RTSP stream as a factory  default.    NOTE : Refer to the ‘ Media Data manual.pdf’ for analyzing the stream of video, audio or meta  data.  RTSP Configuration for UNICAST It is same as the configuration of multicast stream except for the items below.     Only for multicast system: IP Address, Port, and TTL  Ports list for GANZ ENCODER AND NETWORK CAMERA connection Refer to the document TE0301 Ports list for protocol.pdf for detailed information about port  number. It is found in the SDK (\DOC)  2010/2‐1  03A.00    53 ...
  • Page 54: Setting Property For Mdns (Multicast Dns)

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.8. Setting property for mDNS (Multicast DNS)   If you have your own program or device which is required to use the mDNS, this page helps  you to customize the name of model and manufacturer instead of factory default.    Configuration  If you check the box of ‘Enable,’ mDNS is activated. You can type the Friendly Name to be  shown on the application program.    Customize Manufacturer Description  You can type the manufacturer’s name and home URL of your NVC. ‘CBC’ is typed as a default  for the name but it is adjustable as you want.     Customize Model Description  You can type the model name, description of the model and URL of your NVC. ‘ENC is typed as  a default for the name but it is adjustable as you want.  2010/2‐1  03A.00    54 ...
  • Page 55: Setting Smtp

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.9. Setting SMTP     You can set the user’s mail account and server to apply this SMTP for event or any other SMTP  required purpose.  Configuring user information Unit Name  Type the friendly NVC server name to show on e‐mail and it helps you to distinguish the  devices from other devices when you use multiple network video servers.  Input range: 40 characters limit    From email address  Type the e‐mail address of a sender.  Input range: 128 characters limit    Configuring server information Mail server  In order to send the e‐mail message, NVC needs the information of user’s mail server. Type the  Mail server with the host name or IP Address. If you use the host name, it requires the DNS  registration in advance. Check the DNS setting on System Options – TCP/IP tab.  Input range: 128 characters limit    Mail server port  2010/2‐1  03A.00    55 ...
  • Page 56 GANZ Network camerab and encoder series  Webpage User's Manual   Type the mail server’s port number with the range from 0 to 65535.    NOTE : If your email server requires encryption process of SSL and TLS?  Check ‘Enable encrypted connection (SSL)’ box. TLS (Transport Layer Security) and SSL (Secure  Sockets Layer) algorithm can be required for the security of communication over networks. It  depends on your email server and you should check out the communication protocol of SMTP  server.  Logon Information User name  Input range: 128 characters limit    Password   Input range: 32 characters limit    Test with current configuration You can check out in advance if the e‐mail account is available or not with the ‘test’ button.  Type the e‐mail address and click the test button. If you have seen the message below, you  should set the DNS first at [System Option] – [TCP/IP] menu.          If you have seen the message below, the entered mail account is valid.    2010/2‐1  03A.00    56 ...
  • Page 57: Recording & Playback With Usb/Sd Storage

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.10. Recording & Playback with USB/SD storage   Steps for manual recording Step 1. Enable recording  If you want to record the data, the box of Enable Recorder must be checked. If not, the data  is not recorded even if you click the START button.    Enable automatic recording shortly after mounting storage device  It  allows  the  recording  get  started  automatically  as  soon  as  storage  device  is  mounted.  If  you  remove  the  tick,  the  recording  will  be  started  only  when  you  command  of  recording ...
  • Page 58 AND NETWORK CAMERA does not record neither of 1st stream nor 2nd stream.   Option. Recording secondary stream (snapshot stream)  Why secondary recording is required?  As  you  have  found  on  the  GANZ  ENCODER  AND  NETWORK  CAMERA  specification,  GANZ  ENCODER  AND  NETWORK  CAMERA  supports  the  multiple  streams.  For  each  of  camera  input source, the GANZ ENCODER AND NETWORK CAMERA is able to generate 1st stream,  2nd  stream,  and  Snapshot  stream,  which  is  called  triple  stream.  The  secondary  recording ...
  • Page 59 GANZ Network camerab and encoder series  Webpage User's Manual     Step 7. If you have finished the setting above, click the Apply button to save and apply the  setting.   Step 8. Now, click START or STOP button to start or stop recording.    Steps for VCA event recording All of configuration is the same as manual recording but optionally, you have to set up ‘Event  Recording’ tab.        Step 1. Set the time of post‐alarm recording. Then, when VCA event is triggered, the images  will be recorded for the configured time only.  Step 2. Check the box of ‘Enable automatic recording with VCA event triggering’ to enable the  VCA event recording.  How to play back the recoding file on the webpage 1. Click the LIST button at the bottom of the page.  2. Then, you can see the new window is opened as below. The created directories are listed on  the web page.         3. Click one of the directories you want. Then, you can see the recording files are listed.    2010/2‐1  03A.00 ...
  • Page 60 GANZ Network camerab and encoder series  Webpage User's Manual       4. Click the file you want to open. Then, the download window appears as below. You can  open or save the file on your local disk.        2010/2‐1  03A.00    60 ...
  • Page 61: Led Setting

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.11. LED Setting NOTE  :  This  LED  setting  page  is  based  on  ZN‐S1000VE  and  this  page  can  be  different  according to your GANZ ENCODER AND NETWORK CAMERA model type. Refer to the chapter  6. REFERENCE TO MODELS.    You can customize the LED operation according to your system requirement. Please refer to  the example scenario first.   Example of configuration Scenario :  “When the video signal loss is detected, let top LED blink for every 5 seconds”    Setting :  Top Yellow ‐ Ticked  Event Publisher ‐ vsignal  Operation ‐ Blink  Time Out – 5  Option – Turn on the LED of vsignal : Select ‘When video signal loss is detected’.    Basic configuration 1. Check the ‘Enable LED’ box to enables the LED function. ...
  • Page 62 GANZ Network camerab and encoder series  Webpage User's Manual   3. Select the ‘Operation Type’ of each LED, Blink or On mode.  4. Select the ‘Time Out’, among 1 ~ 5 sec or permanent alarming.    Location of LED  In case of ZN‐S1000VE, you can find that there are 2 LEDs on the left side of the video input  port.  Each of GANZ ENCODER AND NETWORK CAMERA series has different position of LEDs  and you should refer to the ‘Hardware Installation guide’ of your model (Refer to the \DOC of  your SDK)  If you are configuring DSP load, temperate, and video signal loss? The option page provides the configuration of DSP load, temperature change, and video loss.    (1) Set the dspload limits to   E.g. Setting the value as 90% ‐ While the DSP load keeps lower than 90%, the LED will operate  as you configured at Location tab.  (2) Set the temperature limits to   E.g. Setting the min 0 and max 65 ‐ While the temperature is between 0 and 65, the LED will  operate as you configured at Location tab.  (3) Turn on the LED of Vsignal   Select one of the options between ‘When video signal loss is detected’ and ‘When video signal  is normal’. Then, the selected LED will operate when the selected condition is satisfied.  (4) Turn on the LED of Heartbeat  Select one of the options between ‘When heartbeat status is watchdog’ and ‘When heartbeat  status is normal’. Then, the selected LED will operate when the selected condition is satisfied.    NOTE :   For more details about the publisher’s triggers condition, refer to the ‘NVC Event System  Manual.pdf’ in the SDK. It describes the threshold for event triggering, event message format,  and triggering condition etc. ...
  • Page 63: Ddns (Dynamic Dns)

    GANZ Network camerab and encoder series  Webpage User's Manual   4.5.12. DDNS (Dynamic DNS)     1. Check the ‘Enable DDNS’ box.  2. Select the protocol type you want.     NOTE : Only DynDNS is installed. Ask UDP support team for adding more servers.    3. Type the domain name you want to use for the GANZ ENCODER AND NETWORK CAMERA.  4. Type the update time. The factory default is 600 seconds and it enables the GANZ ENCODER  AND NETWORK CAMERA notify the DDNS of the current domain name.  5. Type the user name and password of  your DDNS account.  6. Click Apply button.  2010/2‐1  03A.00    63 ...
  • Page 64: Io Configuration

    GANZ Network camerab and encoder series  Webpage User's Manual   4.6. IO CONFIGURATION 4.6.1. DI/DO control NOTE : This DI/DO setting page is based on 1 channel encoder, ZN‐S1000VE. If your camera  or encoder model is other than ZN‐S1000VE, move to the chapter ‘6.REFERENCE TO MODEL’  and you can refer to the different part only from this page.    If you should install the additional device such as alarm system or sensor system, you can  configure the DI (Digital Input) and DO(Digital Out) in this page.    DI Resource Type You can choose the DI resource type, RELAY or VOLTAGE (The maximum is 5V).  DI & DO Status It reflects the current states of actual DI and DO. In case of ZN‐S1000VE, 2 of DI and DO are  supported for each. Refer to your GANZ ENCODER AND NETWORK CAMERA model  specification for supported number of DI and DO.     Scenario Example  When it’s assumed that DI#1 and DO#1 are coupled by event system. The DI#1 trigger type is  Normal Open. Suddenly DI#1 is triggered by any kind of event.   2010/2‐1  03A.00    64 ...
  • Page 65 GANZ Network camerab and encoder series  Webpage User's Manual   Expected Response – The status of DO#1 will be changed from OFF to ON, if the default setting  is OFF. The status of DI#1 will be changed from OPEN to CLOSE.  DO Control If you want to test DO operation manually on the webpage, click the soft buttons of OFF and  ON. Then, you can see that how DO works. These commands also affects the ‘DO status’   because the ‘DO status’ shows the current status of DO.  Friendly Name You can type any friendly name for DI and DO. This setting helps you to identify which DI or DO  is activated especially when you have multiple NVC servers on your application program.  DI Trigger Type You can select the trigger type between normal open (NO) and normal close (NC).   DI Interval between triggers It is the detection time interval for event publishers. For example, if ‘0’ is typed, it generates  events every time for DI detection. But if ‘10’ is typed, that means even if multiple DIs are  detected for 10 seconds, they will trigger only 1 event for that 10 seconds.  DO Working Time It is about the working time of the DO.  For example, if ‘0’ is typed, DO device keep working until a user turns it off manually. If ‘10’ is  typed, DO device will work for 10 seconds and will finish the operation.   2010/2‐1  03A.00    65 ...
  • Page 66: Uart Setting For Serial Device

    GANZ Network camerab and encoder series  Webpage User's Manual   4.6.2. UART setting for serial device NOTE : This UART setting page is based on 1 channel encoder, ZN‐S1000VE. If your camera or  encoder model is other than ZN‐S1000VE, move to the chapter ‘6.REFERENCE TO MODEL’  and you can refer to the different part only from this page.    2010/2‐1  03A.00    66 ...
  • Page 67 GANZ Network camerab and encoder series  Webpage User's Manual   UART1 – RS485 only supported   Internal   RS485‐PTZ : Used when you attach a PTZ camera to the NVC series.   RS485‐AUX : Used when you attach any auxiliary device which requires serial communication  to the NVC series.    RS232‐PTZ : Not supported for UART1 port  RS232‐AUX : Not supported for UART1 port    Why distinguish between RS485‐PTZ and RS485‐AUX?  When the RS485‐PTZ is selected, the required PTZ protocol and the control daemon are run  and assigned to the serial communication internally.    External   When 3  party program is added to the server side of NVC and this add‐on program needs to  control the attached serial devices, you should select the external option. So, if you do not use  any serial control program, you can ignore this option.  RS485‐AUX : When add‐on program for RS485 communication is required  RS232‐AUX : Not supported for UART1 port   UART2 – RS232C only supported   Internal   RS232‐PTZ : Used when you attach a PTZ camera to the NVC series.   RS232‐AUX : Used when you attach any auxiliary device other than PTZ camera.    Why distinguish between RS232‐PTZ and RS232‐AUX?  2010/2‐1  03A.00    67 ...
  • Page 68 GANZ Network camerab and encoder series  Webpage User's Manual   When the RS485‐PTZ is selected, the required PTZ protocol and the control daemon are run  and assigned to the serial communication internally.  External   When 3  party program is added to the server side of NVC and this add‐on program needs to  control the attached serial devices, you should select the External option. So, if you do not use  any serial control program, you can ignore this external option.    SerialOverIP What is SerialOverIP?  When you want to read/write the serial data from attached serial device over the network,  you can select this ‘SerialOverIP’ option. Refer to the drawing below for more specific schema.  Serial  Network    Communication Serial device (e.g.  Client PC  GANZ ENCODER  PTZ camera)  IP address / port  required      You can find the test tool for SerialOverIP  at \BIN\TOOLS\ SerialOverHttp.exe of NVC SDK.  Select the com port of PC Select the type ‘NVC’ Type the IP address of PC     NOTE : This tool is designed to test a ‘writing only’ for data sending from PC to NVC. For the  opposite direction (from NVC to PC), you should use another program or use HTTP API. NVC  HTTP API Manual.pdf at \DOC of NVC SDK will help you to use HTTP API of serial data  communication. Refer to the section 0.6.3. Serial2.fcgi.    PTZ Protocol  PTZ Name : You need to set the UART type as RS485‐PTZ before selecting the PTZ protocol. If  you click the drop down box of PTZ name, the available protocols are listed. Choose the ...
  • Page 69: Maintenance

    GANZ Network camerab and encoder series  Webpage User's Manual   4.7. MAINTENANCE 4.7.1. Firmware Update port setting   Firmware update is allowed only by the ZNS‐GIT IPAdimn Tool.exe, which is provided in the  SDK (\BIN\TOOLS\AdminTool vX.X.X.X). Refer to the ‘NVC Tools User’s Manual.pdf’ to find out  how to update the firmware on your GANZ ENCODER AND NETWORK CAMERA.     Before you upload the firmware with ZNS‐GIT IPAdimn Tool.exe, check the ‘Enable Firmware  Update’ box and set the port number. If you remove the check this box, updating the firmware  is not allowed.  2010/2‐1  03A.00    69 ...
  • Page 70: Getting System Log

    GANZ Network camerab and encoder series  Webpage User's Manual   4.7.2. Getting system Log   In order to get the system log of GANZ ENCODER AND NETWORK CAMERA series, please follow  the steps of below.  1. Check the ‘Enable System Log’ box  2. Type  max  size  of  file  between  32KB  and  200KB.  Then,  the  log  files  will  be  created  according to the fixed size (Up to 5 files are created and the oldest file will be replaced  by the latest file).  3. Click Apply button and then the log file will be created.    If you want to see the log list, click the LOG LIST button.     Name : The log files are named automatically. It’s not allowed for user to name it manually.    Size : Log file size is updated in real time.  Latest access time : Latest time when GANZ ENCODER AND NETWORK CAMERA accessed the  internal system to get the log.   ...
  • Page 71: Webpage Option For Vca

    GANZ Network camerab and encoder series  Webpage User's Manual   4.7.3. Webpage option for VCA   If you check the ‘Display VCA streaming at the VIEW page’, it enables you to get the Video  Contents Analysis stream at the view page.   2010/2‐1  03A.00    71 ...
  • Page 72: Vca

    GANZ Network camerab and encoder series  Webpage User's Manual   4.8. VCA Refer to the separate documents, VCAsys.chm in the SDK (path : \DOC).  4.9. MOTION DETECTION E  A  To create new  zone:   You can adjust  Enable the box  The location of  the sensitivity    Sensitivity and  the zone is  and objectsize  To delete the    ObjectSize user  shown with of each zone.  existing zone:  configured are  normalized  Remove the  shown  figures.  check in the box    The picture above is the example of zone setting on the highway image.   How to configure the motion detection zones: 1.
  • Page 73 GANZ Network camerab and encoder series  Webpage User's Manual   What is Sensitivity?  Every motion detection zone is divided into multiple squares, which is called ‘Macro blocks.’  And each of macro blocks consists of 16 x 16 pixels. The value of sensitivity means the  sensitivity of each macro block. If you want to configure the zone less sensitive than the  factory default, set the figure higher by dragging the bar of section D. Likewise, if you want to  configure the zone more sensitive than the factory default, set the figure lower.    What is Objectsize?  The objectsize value means the proportion of the macro blocks which has exceeded the  configured sensitivity. If you want to configure the zone less sensitive than the factory default,  set the figure higher by dragging the bar of section D. Likewise, if you want to configure the  zone more sensitive than the factory default, set the figure lower.  2010/2‐1  03A.00    73 ...
  • Page 74: About

    GANZ Network camerab and encoder series  Webpage User's Manual   4.10. ABOUT 4.10.1. Version   You can find the information about the current firmware version on the top of the page.  Hardware and software version information etc are found in this page as well.   4.10.2. Licenses   Third Party Software License  When you have added the third party software on GANZ encoder, you can use this page to  check out the licenses.     2010/2‐1  03A.00    74 ...
  • Page 75: Safety Mode

    GANZ Network camerab and encoder series  Webpage User's Manual   5. SAFETY MODE 5.1. What is Safety Mode? Your GANZ encoder and network camera system could encounter an unexpected occasion  such as broken firmware file or uncompleted loading of firmware file during system booting.  To restore the system after the emergency cases, GANZ encoder and network camra system  provides the emergency firmware as a factory default. Your system will get restarted with  Safety Mode when there is any error on your booting system files.  5.2. Why your GANZ encoder and network camera system boots in Safety Mode? Normally, the cause of ‘safety mode’ is classified into 3 types.  * When the power supply is unplugged in the middle of system booting.  * When the firmware files required for system booting are damaged.  * When a user has not completed the booting files system and try to boot the system (Applied  only for the case of Server Side SDK user)    IMPORTANT : GANZ ENCODER AND NETWORK CAMERA do not turn into the safety mode  booting until 5 times of normal booting are tried.   5.3. How to recover your system from Safety Mode?  ...
  • Page 76: Limited Functions Under Safety Mode

    Click the ‘Reboot’ button on the webpage  1. Wait for about 1 minute until the system gets restarted at normal condition.  2. Try to access the webpage again and check out if it displays the webpage in normal.  If your system still keeps rebooting at Safety Mode even with the steps of above?   It means some parts of your firmware files on the system are damaged and not available any  more. Please try the steps of below to recover the firmware file.  1. Run  the  ZNS‐GIT  IPAdimn  Tool.exe  program  in  the  SDK  (\BIN\TOOLS\AdminTooL).  Then,  you  may  find  that  your  GANZ  encoder  and  network  camera  is  with  ‘Safety  Mode’ on the ZNS‐GIT IPAdimn Tool as below.  2. Right‐click at the device name and select the ‘Update’ menu.  NOTE : Please find the detailed instruction to update firmware, which is located at SDK (\DOC).  The section ‘2.6. How to update firmware remotely by ZNS‐GIT IPAdimn Tool’ will guide you to  understand the updating procedure.  If you have completed the firmware update, you can access the webpage and check out if your ...
  • Page 77: Reference To Models

    GANZ Network camerab and encoder series  Webpage User's Manual   6. REFERENCE TO MODELS 6.1. ZN-S100V Event Configuration Only Video, Motion Detection, VCA, Network, and Health are supported for the event  publisher (DI/DO are NOT supported). Refer to the section 4.4. Event Configuration for the  explanation of the event setting.    DI/DO is NOT supported  as an event trigger.    USB/SD Storage USB/SD ports are NOT supported.  USB Wireless LAN USB port for Wireless LAN is NOT supported.  DI/DO Control DI/DO is NOT supported.  UART Setting for serial device Serial communication available for users is NOT supported.  2010/2‐1  03A.00    77 ...
  • Page 78: Zn-Rs4000 Series

    GANZ Network camerab and encoder series  Webpage User's Manual   6.2. ZN-RS4000 SERIES Video Input TBD  Event Configuration TBD  USB/SD Storage TBD  USB Wireless LAN TBD  DI/DO Control TBD  UART Setting for serial device TBD  2010/2‐1  03A.00    78 ...
  • Page 79: Rack For Ganz Encoder

    GANZ Network camerab and encoder series  Webpage User's Manual   6.3. Rack for GANZ encoder 4 separate modules are installed on each blade of ZN‐RS4000 SERIES. And each of module  works as ZN‐S1000VE, 1channel encoder solution does in most of specification but some of  functions are limited and refer to the explanation of the below.   Video Input 4 video inputs are supported and the user interface of video input per module is as same as  ZN‐S1000VE.  Event Configuration Module 0: DI/DO are supported for event publisher  Module 1: DI/DO are supported for event publisher  Module 2: DI/DO are NOT supported for event publisher  Module 3: DI/DO are NOT supported for event publisher  USB/SD Storage 1 of USB storage per 1 blade is supported (module0)  SD is NOT supported  USB Wireless LAN Module0 only supported  DI/DO Control Module 0: 2 of DI / 1 of DO are supported   Module 1: 2 of DI / 1 of DO are supported   Module 2: DI/DO are NOT supported   Module 3: DI/DO are NOT supported   UART Setting for serial device RS232C ‐ Module0 only supported ...
  • Page 80: Zn-D100Ve

    GANZ Network camerab and encoder series  Webpage User's Manual   6.4. ZN-D100VE Video Input The Video Standard Format of video input depends on the lens type of your ZN‐D100VE. If your  camera has the type of CMOS lens, the video standard format will show you CMOS selected  configuration on the webpage.    2010/2‐1  03A.00    80 ...
  • Page 81 GANZ Network camerab and encoder series  Webpage User's Manual   You can control the exposure  of camera by selecting ‘auto’  or ‘manual’ to improve the  You can slow the shutter  image quality.  speed by setting target value.    This is used when it is too dark  Auto : It controls the  and need to get more of light  exposure automatically.  by slowing the shutter speed.   Manual : You can improve    the quality of image by  ‐Based on full 30 fps‐  configuring the target value  1/2 : 15 fps (every 66ms)  of exposure. Higher figure  1/4: 7.5 fps (every 133ms)  means better image quality.  1/8 : 3.75 fps (every 266ms) The quality is optimized by  user’s configuration of  shutter speed and AGC.    Event Configuration Only Video, Motion Detection, VCA, Network, and Health are supported for the event  publisher (DI/DO are not supported). Refer to section 4.4. Event Configuration for the  explanation of the setting.  2010/2‐1  03A.00    81 ...
  • Page 82 GANZ Network camerab and encoder series  Webpage User's Manual   DI/DO is NOT supported  as an event trigger.    USB/SD Storage USB/SD ports are NOT supported.  USB Wireless LAN USB port for Wireless LAN is NOT supported.  DI/DO Control DI/DO is NOT supported.  UART Setting for serial device Serial communication available for users is NOT supported.  2010/2‐1  03A.00    82 ...
  • Page 83: Zn-Cs Series H.264 Network Camera

    GANZ Network camerab and encoder series  Webpage User's Manual   6.5. ZN-CS series H.264 Network camera Video Input Camera OSD Menu Control  For OSD menu operation, refer to the ‘ZN‐CS series H.264 Network camera OSD Menu Control  Manual’ in the SDK (\DOC).    Baud rate is fixed as  38400 bps (Not  adjustable by user)      Refer to the section 4.3. VIDEO & AUDIO for more information about settings other than  Camera OS menu Control.  2010/2‐1  03A.00    83 ...
  • Page 84 GANZ Network camerab and encoder series  Webpage User's Manual   Event Configuration Refer to the section 4.4. EVENT CONFIGURATION for the explanation of the setting.  USB/SD Storage Refer to the section 4.5. SYSTEM OPTION for the explanation of the setting.  USB Wireless LAN Refer to the section 4.5. SYSTEM OPTION for the explanation of the setting.    2010/2‐1  03A.00    84 ...
  • Page 85 GANZ Network camerab and encoder series  Webpage User's Manual   DI/DO Control of ZN-CS series H.264 Network camera The number of supported DI and DO  DI : #1  DO : #1    Refer to the section 4.6. IO CONFIGURATION for more explanation of the setting.    2010/2‐1  03A.00    85 ...
  • Page 86 GANZ Network camerab and encoder series  Webpage User's Manual   UART Setting for serial device of ZN-CS series H.264 Network camera Refer to the section 4.6.  IO CONFIGURATION for  the explanation of these  setting.     UART0 : Reserved for the internal debugging purpose with RS232C.  UART1 : RS485 port  UART2 : Reserved for the communication of camera OSD control     IMPORTANT : Only UART1 is available for users but UART0 and UART2 are reserved for  internal communication purpose which are not opened to users.    NOTE : The UART setting depends on the hardware version and firmware version of your  device. The setting configuration of above is based on the hw v1.3 / firmware v1.00.06. You  can check out the version information at [Setup] – [About] – [Version] tab of the webpage.    NOTE : If you want the RS232C, please use the 485‐232 converter.  2010/2‐1  03A.00    86 ...
  • Page 87: Zn-Dt350 Series H.264 Network Dome Camera

    GANZ Network camerab and encoder series  Webpage User's Manual   6.6. ZN-DT350 series H.264 Network dome camera   Camera OSD Menu Control For OSD menu operation, independent manual is provided.   Refer to the ‘ZN‐DT350 series H.264 Network dome camera OSD Menu Control Manual’ in the  SDK (\DOC)  Event Configuration Refer to the section 4.4. EVENT CONFIGURATION for the explanation of the setting.  USB/SD Storage Only SD supported.  USB Wireless LAN USB port for Wireless LAN is NOT supported.  2010/2‐1  03A.00    87 ...
  • Page 88 GANZ Network camerab and encoder series  Webpage User's Manual   DI/DO Control of ZN-DT350 series H.264 Network dome camera The number of supported DI and DO  DI : #1  DO : #1    Refer to the section 4.6. IO CONFIGURATION for the explanation about the setting.    2010/2‐1  03A.00    88 ...
  • Page 89 GANZ Network camerab and encoder series  Webpage User's Manual   UART Setting for serial device     UART0 : Reserved for the internal debugging purpose with RS232C.  UART1 : RS485 port  UART2 : Reserved for the communication of camera OSD control     IMPORTANT : Only UART1 is available for users but UART0 and UART2 are reserved for  internal communication purpose which are not opened to users.    NOTE : The UART setting depends on the hardware version and firmware version of your  device. The setting configuration of above is based on the hw v1.3 / firmware v1.00.06. You  can check out the version information at [Setup] – [About] – [Version] tab of the webpage.    NOTE : If you want the RS232C, please use the 485‐232 converter.    2010/2‐1  03A.00    89 ...