GANZ Network camerab and encoder series
Webpage User's Manual
What is Sensitivity?
Every motion detection zone is divided into multiple squares, which is called 'Macro blocks.'
And each of macro blocks consists of 16 x 16 pixels. The value of sensitivity means the
sensitivity of each macro block. If you want to configure the zone less sensitive than the
factory default, set the figure higher by dragging the bar of section D. Likewise, if you want to
configure the zone more sensitive than the factory default, set the figure lower.
What is Objectsize?
The objectsize value means the proportion of the macro blocks which has exceeded the
configured sensitivity. If you want to configure the zone less sensitive than the factory default,
set the figure higher by dragging the bar of section D. Likewise, if you want to configure the
zone more sensitive than the factory default, set the figure lower.
2010/2‐1 03A.00
73
Need help?
Do you have a question about the H.264 Network Encoder Series and is the answer not in the manual?