GANZ Network camerab and encoder series
Webpage User's Manual
3. Select the 'Operation Type' of each LED, Blink or On mode.
4. Select the 'Time Out', among 1 ~ 5 sec or permanent alarming.
Location of LED
In case of ZN‐S1000VE, you can find that there are 2 LEDs on the left side of the video input
port. Each of GANZ ENCODER AND NETWORK CAMERA series has different position of LEDs
and you should refer to the 'Hardware Installation guide' of your model (Refer to the \DOC of
your SDK)
If you are configuring DSP load, temperate, and video signal loss?
The option page provides the configuration of DSP load, temperature change, and video loss.
(1) Set the dspload limits to
E.g. Setting the value as 90% ‐ While the DSP load keeps lower than 90%, the LED will operate
as you configured at Location tab.
(2) Set the temperature limits to
E.g. Setting the min 0 and max 65 ‐ While the temperature is between 0 and 65, the LED will
operate as you configured at Location tab.
(3) Turn on the LED of Vsignal
Select one of the options between 'When video signal loss is detected' and 'When video signal
is normal'. Then, the selected LED will operate when the selected condition is satisfied.
(4) Turn on the LED of Heartbeat
Select one of the options between 'When heartbeat status is watchdog' and 'When heartbeat
status is normal'. Then, the selected LED will operate when the selected condition is satisfied.
NOTE :
For more details about the publisher's triggers condition, refer to the 'NVC Event System
Manual.pdf' in the SDK. It describes the threshold for event triggering, event message format,
and triggering condition etc.