Ganz H.264 Network Encoder Series User Manual page 65

Table of Contents

Advertisement

GANZ Network camerab and encoder series 
Webpage User's Manual  
Expected Response – The status of DO#1 will be changed from OFF to ON, if the default setting 
is OFF. The status of DI#1 will be changed from OPEN to CLOSE. 
DO Control
If you want to test DO operation manually on the webpage, click the soft buttons of OFF and 
ON. Then, you can see that how DO works. These commands also affects the 'DO status'  
because the 'DO status' shows the current status of DO. 
Friendly Name
You can type any friendly name for DI and DO. This setting helps you to identify which DI or DO 
is activated especially when you have multiple NVC servers on your application program. 
DI Trigger Type
You can select the trigger type between normal open (NO) and normal close (NC).  
DI Interval between triggers
It is the detection time interval for event publishers. For example, if '0' is typed, it generates 
events every time for DI detection. But if '10' is typed, that means even if multiple DIs are 
detected for 10 seconds, they will trigger only 1 event for that 10 seconds. 
DO Working Time
It is about the working time of the DO. 
For example, if '0' is typed, DO device keep working until a user turns it off manually. If '10' is 
typed, DO device will work for 10 seconds and will finish the operation.  
2010/2‐1  03A.00 
 
65 