Description of the data path
Channel balance
All KODAK PIKE sensors are read out via two channels: the first channel for
the left half of the image and the second channel for the right half of the
image (divided by a central vertical line).
All KODAK equipped cameras come with a sensor-specific pre-adjusted chan-
nel balance.
However in some cases it may be advantageous to carry out a fine adjustment
with the so-called channel balance.
To carry out an adjustment in an advanced register: see
register: Channel balance
Channel adjustment with SmartView (>1.5)
Prerequisites:
•
Test sheet with continuous b/w gradient
•
PIKE camera with defocused lens
•
PIKE color cameras set to RAW8 and RAW16
•
In case of using AOI, be aware that the middle vertical line (+/- 20
pixel) is part of the AOI.
To carry out an adjustment in SmartView, perform the following steps:
1. In SmartView click Extras
The following window opens:
Figure 50: SmartView: channel adjustment
Note
Program button is only available for AVT factory.
on page 290.
Adjust channels... or use Alt+Ctrl+A.
Table 143: Advanced
PIKE Technical Manual V4.1.0
96