Changing The Parameters Within A Sequence; Points To Pay Attention To When Changing The Parameters - AVT Pike Technical Manual

Table of Contents

Advertisement

Controlling image capture

Changing the parameters within a sequence

To change the parameter set for one image, it is not necessary to modify the
settings for the entire sequence. The image can simply be selected via the
ImageNo field and it is then possible to change the corresponding IIDC
V1.31 registers.
Points to pay attention to when changing the
parameters
Note
• If the ApplyParameters flag is used when setting the
parameters, all not-configured values are set to default
values. As changing a sequence normally affects only
the value of a specific register, and all other registers
should not be changed, the ApplyParameters flag may
not be used here.
• The values stored for individual images can no longer
be read.
• If the camera is switched into sequence mode, the
changes to the IIDC V1.31 registers for the image spec-
ified in ImageNo take immediate effect.
• Sequence mode requires firmware 3.x and special care if
changing image size and frame rate related parameters.
This is because these changes not only affect settings
in the camera but also require corresponding settings in
the receiving software in the PC (e.g. FirePackage).
Caution
Incorrect handling may lead to image corruption or loss of
subsequent images.
Please ask for detailed support when you want to use this
feature.
PIKE Technical Manual V4.1.0