User Adjustable Gain References - AVT Pike Technical Manual

Table of Contents

Advertisement

Configuration of the camera
Offset
Name
0xF1002000
AFEREFERENCES
0xF1002004
GAINREFERENCE
Table 165: Advanced register: User adjustable gain references
Pike model
Pike F-032B/C
Pike F-100B/C
Pike F-145B/C (15fps)
Pike F-145B/C (30fps)
Pike F-210B/C
Pike F-421B/C
Pike F-505B/C

User adjustable gain references

This register gives the user the possibility (via direct access) to modify the
gain references. Modified values are stored automatically without further
user action and are also stored on restart.
To reload default gain references (which are programmed at personalization)
within the camera: set flag m_bDefGainRef=1
Field
Presence_Inq
---
m_bDefGainRef [5]
---
m_GainRef
In the following table you find the default gain references of all Pike models:
Default gain reference (decimal)
200
210
30 (15*)
85 (15*)
215
200
115 ( 130*)
Table 166: default gain references of Pike models
*: Firmware package version 00.03.00.01 or earlier
Bit
Description
[0]
Indicates presence of this feature
(read only)
[1..4]
Reserved
Reload default gain references, if
this flag is set.
[6..31]
Reserved
[0..31]
Gain reference (0..511)
Default gain reference (hex)
1Eh (0Fh*)
55h (0Fh*)
73h (82h*)
PIKE Technical Manual V4.1.0
C8h
D2h
D7h
C8h
310

Advertisement

Table of Contents
loading

Table of Contents