Setup Mode (New For 3.X); Sequence Step Mode (New For 3.X) - AVT Pike Technical Manual

Table of Contents

Advertisement

Controlling image capture
Register
Name
0xF1000228
SEQUENCE_STEP
0xF100022C
SEQUENCE_RESET
Field
Presence_Inq
---
PerformStep
PerformReset
---
SeqPosition
Presence_Inq
---
PerformReset
---
Table 67: Advanced register: Sequence mode
Enabling this feature turns the camera into a special mode. This mode can be
used to set up a bunch of parameter sets for up to MaxLength consecutive
images.
Note
The sequence mode of the Pike 3.x series firmware behaves
slightly different than the sequence mode of e.g. the Marlin
series and implements some new controlling features. You
may use a sequence with internal or external trigger and with
the Deferred Transport feature.

Setup mode (new for 3.x)

The SetupMode flag allows you to set up a sequence while capturing images.
Using this flag you get a visual feedback of the settings.
Set SetupMode flag when setting up the sequence and reset the flag before
using the sequence.

Sequence step mode (new for 3.x)

The SeqMode field selects the signal source for stepping the sequence one
parameter set further.
Bit
Description
[0]
Indicates presence of this feature
(read only)
[1..4]
Reserved
[5]
Sequence is stepped one item for-
ward
[6]
Sequence reset
[7..23]
Reserved
[24..31] Get the current sequence position
[0]
Indicates presence of this feature
(read only)
[1..4]
Reserved
[5]
Reset the sequence to start position
[6..31]
Reserved
PIKE Technical Manual V4.1.0