Camera interfaces

Control and video data signals

Input signal
The inputs and outputs of the camera can be configured by software. The dif-
ferent modes are described below.

Inputs

Note
For a general description of the inputs and warnings see the
Hardware Installation Guide, Chapter PIKE input descrip-
tion.
The optocoupler inverts all input signals. Inversion of the signal is controlled
via the IO_INP_CTRL1..2 register (see
control
on page 82).
Opto-
Coupler
Figure 42: Input block diagram

Triggers

All inputs configured as triggers are linked by AND. If several inputs are being
used as triggers, a high signal must be present on all inputs in order to gen-
erate a trigger signal. Each signal can be inverted. The camera must be set
to external triggering to trigger image capture by the trigger signal.
Table 22: Advanced register: Input
Polarity
selectable
via software
Input
Input state
PIKE Technical Manual V4.1.0
81