Look-Up Tables (Lut) - AVT Pike Technical Manual

Table of Contents

Advertisement

Configuration of the camera
Register
Name
0xF1000240
LUT_CTRL
0xF1000244
LUT_MEM_CTRL
0xF1000248
LUT_INFO

Look-up tables (LUT)

Load the look-up tables to be used into the camera and choose the look-up
table number via the LutNo field. Now you can activate the chosen LUT via
the LUT_CTRL register.
The LUT_INFO register indicates how many LUTs the camera can store and
shows the maximum size of the individual LUTs.
The possible values for LutNo are 0..n-1, whereas n can be determined by
reading the field NumOfLuts of the LUT_INFO register.
Field
Presence_Inq
---
ON_OFF
---
LutNo
Presence_Inq
---
EnableMemWR
---
AccessLutNo
AddrOffset
Presence_Inq
---
BitsPerValue
NumOfLuts
MaxLutSize
Table 131: Advanced register: LUT
Bit
Description
[0]
Indicates presence of this
feature (read only)
[1..5]
Reserved
[6]
Enable/disable this feature
[7..25]
Reserved
[26..31] Use look-up table with LutNo
number
[0]
Indicates presence of this
feature (read only)
[1..4]
Reserved
[5]
Enable write access
[6..7]
Reserved
[8..15]
Reserved
[16..31] byte
[0]
Indicates presence of this
feature (read only)
[1..2]
Reserved
[3..7]
Bits used per table item
[8..15]
Maximum number of look-up
tables
[16..31] Maximum look-up table size
(bytes)
PIKE Technical Manual V4.1.0