Configuration of the camera
Register
Name
0xF1000270
FRAMEINFO
0xF1000274
FRAMECOUNTER
Frame information
This register can be used to double-check the number of images received by
the host computer against the number of images which were transmitted by
the camera. The camera increments this counter with every FrameValid sig-
nal. This is a mirror of the frame counter information found at 0xF1000610.
Field
Presence_Inq
ResetFrameCnt
---
FrameCounter
Table 135: Advanced register: Frame information
The FrameCounter is incremented when an image is read out of the sensor.
The FrameCounter does not indicate whether an image was sent over the
IEEE 1394 bus or not.
Input/output pin control
Note
• See Chapter
• See Chapter
• See Chapter
• See Chapter
Bit
Description
[0]
Indicates presence of this
feature (read only)
[1]
Reset frame counter
[1..31]
Reserved
[0..31]
Number of captured frames
since last reset
Input/output pin control
IO_INP_CTRL 1-2
on page 83
IO_OUTP_CTRL 1-4
on page 87
Output modes
on page 88
PIKE Technical Manual V4.1.0
on page 82
283