One-Shot Command On The Bus To Start Of Exposure - AVT Pike Technical Manual

Table of Contents

Advertisement

Controlling image capture
One-shot command on the bus to start of
exposure
The following sections describe the time response of the camera using a sin-
gle frame (one-shot) command. As set out in the IIDC specification, this is
a software command that causes the camera to record and transmit a single
frame.
The following values apply only when the camera is idle and ready for use.
Full resolution must also be set.
Feature
One-shot
microcontroller sync
µC-Sync/ExSync
integration start 8 µs
Microcontroller sync is an internal signal. It is generated by the microcon-
troller to initiate a trigger. This can either be a direct trigger or a release for
ExSync if the camera is externally triggered.
Value
≤ 150 µs (processing time in the
microcontroller)
Table 64: Values for one-shot
PIKE Technical Manual V4.1.0
168