Quick Parameter Change Timing Modes; Standard Parameter Update Timing; Quick Format Change Mode - AVT Pike Technical Manual

Table of Contents

Advertisement

Configuration of the camera
Register
Name
0xF1000570
PARAMUPD_TIMING Presence_Inq

Quick parameter change timing modes

You can choose between the following update timing modes:
Standard Parameter Update Timing (slightly modified from previous
PIKE cameras)
New: Quick Format Change Mode
Note
For a detailed description see Chapter
change timing modes
Field
---
UpdActive
---
UpdTiming
Table 148: Advanced register: Update timing modes

Standard Parameter Update Timing

The camera behaves like older firmware versions without this feature. The
UpdActive flag has no meaning.

Quick Format Change Mode

This mode behaves like Standard Parameter Update Timing mode with the
following exception:
An already started image transport to the host will not be interrupted, but
an already started integration will be interrupted.
on page 135.
Bit
Description
[0]
Indicates presence of this feature
(read only)
[1..5]
Reserved
[6]
Update active
see Chapter
(begin/end)
0: (default); reset to 0 means
Encapsulated Update end
1: set to 1 means
Encapsulated Update begin
[7..23]
Reserved
[24..31]
Update timing mode
If set to O:
Standard Parameter Update Timing
is active
If set to 2:
Quick Format Change Mode is active
PIKE Technical Manual V4.1.0
Quick parameter
Encapsulated Update
on page 137
294