Configuration of the camera
Register
Name
0xF1000390 AUTOFNC_AOI
0xF1000394 AF_AREA_POSITION
0xF1000398 AF_AREA_SIZE

Autofunction AOI

The table below illustrates the advanced register for autofunction AOI.
Field
Presence_Inq
---
ShowWorkArea
---
ON_OFF
---
YUNITS
XUNITS
Left
Top
Width
Height
Table 139: Advanced register: Autofunction AOI
The possible increment of the work area position and size is defined by the
YUNITS and XUNITS fields. The camera automatically adjusts your settings to
permitted values.
Note
If the adjustment fails and the work area size and/or work
area position becomes invalid, then this feature is automat-
ically switched off.
Read back the ON_OFF flag, if this feature does not work as
expected.
Bit
Description
[0]
Indicates presence of this
feature (read only)
[1..3]
Reserved
[4]
Show work area
[5]
Reserved
[6]
Enable/disable AOI (see note
above)
[7]
Reserved
[8..19]
Y units of work area/pos.
beginning with 0 (read only)
[20..31]
X units of work area/pos.
beginning with 0 (read only)
[0..15]
Work area position (left
coordinate)
[16..31]
Work area position (top
coordinate)
[0..15]
Width of work area size
[16..31]
Height of work area size
PIKE Technical Manual V4.1.0