Configuration of the camera
Register
Name
0xF1000620 TRIGGER_COUNTER
0xF1000624 TRGCNT

Advanced register: trigger counter

The trigger counter feature is controlled by the following advanced feature
register:
Field
Presence_Inq
Reset
---
TriggerCounter
Table 157: Advanced register: Trigger counter
Having this feature enabled, the current trigger counter value (external trig-
ger seen by hardware) will be inserted as a 32-bit integer value into any cap-
tured image.
Setting the Reset flag to 1 resets the trigger counter to 0: the Reset flag is
self-cleared.
The ON_OFF and LinePos fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.
Note
The 4 bytes of the trigger counter value will be inserted as
the 9th to 12th byte of a line.
Additionally there is a register for direct read out of the trigger counter
value.
Bit
Description
[0]
Indicates presence of this feature
(read only)
[1]
Reset trigger counter
[2..31]
Reserved
[0..31]
Trigger counter
PIKE Technical Manual V4.1.0