Configuration of the camera
Bit
0
1
2
Bit
16
17
18
... Cycle count 13 bit
Register
Name
0xF1000610 FRMCNT_STAMP
0xF1000614 FRMCNT
3
4
5
6
Cycle offset 12 bit
19
20
21
22
Table 155: Cycle timer layout

Advanced register: frame counter

Note
Different to Marlin SIS:
Register 610 is only to be used to reset the frame counter.
The frame counter feature is controlled by the following advanced feature
register:
Field
Presence_Inq
Reset
---
Table 156: Advanced register: Frame counter
Having this feature enabled, the current frame counter value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.
Setting the Reset flag to 1 resets the frame counter to 0: the Reset flag is
self-cleared.
Note
The 4 bytes of the frame counter value will be inserted as
the 5th to 8th byte of a line.
Additionally there is a register for direct read out of the frame counter value.
7
8
9
10
23
24
25
26
Second count 7 bit
Bit
Description
[0]
Indicates presence of this feature
(read only)
[1]
Reset frame counter
[2..31]
Reserved
[0..31]
Frame counter