Configuration of the camera
Register
Name
0xF1000420 CHANNEL_ADJUST_CTRL
0xF1000424 CHANNEL_ADJUST_VALUE ---
Register
Name
0xF1000510 SOFT_RESET
AFE channel compensation (channel balance)
All KODAK Pike sensors are read out via two channels: the first channel for
the left half of the image and the second channel for the right half of the
image.
Channel gain adjustment (Pike color cameras only RAW8 and RAW16) can be
done via the following two advanced registers:
Field
Presence_Inq
---
Balance_Value
Table 143: Advanced register: Channel balance
You can save the current value in the user sets and set to default value.
Soft reset
Field
Presence_Inq
---
Reset
---
Delay
Table 144: Advanced register: Soft reset
The soft reset feature is similar to the INITIALIZE register, with the follow-
ing differences:
•
1 or more bus resets will occur
•
the FPGA will be rebooted
The reset can be delayed by setting the Delay to a value unequal to 0.
The delay is defined in 10 ms steps.
Bit
Description
[0]
Indicates presence of this
feature (read only)
[1..31]
Reserved
[0..15]
Reserved
[16..31]
Signed 16 bit value
-8192...0...+8191
SmartView shows only:
-2048...0...+2047
Bit
Description
[0]
Indicates presence of this
feature (read only)
[1..5]
Reserved
[6]
Initiate reset
[7..19]
Reserved
[20..31]
Delay reset in 10 ms steps
PIKE Technical Manual V4.1.0
290