Section 700 - Operation
Hardware Requirements
N/A
Related Programming
FF3 (Extensions): Ringing Line Preference by Handset.
FF3: Ringing Line Preference (ON/OFF)
Considerations
If disabled in Extension Programming, you must press the line key or enter the feature code for
incoming pick-up in order to answer a call.

Room Monitoring

Version 3.5 and higher
Description
This feature allows the user to monitor the sounds in a room from another extension or room. The
transmitter in the telephone handset is used as a remote "microphone" for monitoring these sounds.
To activate this feature, the monitored extension must enable the Room Monitor feature before the
monitoring extension can listen to the sounds in the room. The monitored extension can be enabled
using a SLT, DSLT, or Key Telephone. No special programming is required to allow an extension to
enable the monitored mode.
Operation
To set up the monitored extension:
1. Dial the monitored extension access code (default 775),
OR...
Note:
The handset must be off-hook to activate the
Room Monitor feature.
Press an FF key assigned with the monitored access code
576-50-700
Action
DBS 576HD (USA) issued September 2001
Chapter 7. SLT Features
Result
You will hear a confirmation tone after
the monitored extension has enabled the
Room Monitor feature. (If the monitored
extension has an LCD display, a confir-
mation message will also be shown.)