Figure 4.25 Configuring Remote Power Supply Of S/T0 To S/T3 Accesses; Indicators - Aastra AXD Installation And Maintenance Manual

Aastra 5000 server installation and maintenance manual
Table of Contents

Advertisement

4.8.2.2

Indicators

The EXT1-S card does not have any indicators on the front panel.
4.8.3
Hardware and software configuration
The EXT1-S card has 4 jumpers for configuring remote power supply of the S/T0 to S/T3
accesses (one jumper block for each access). These jumpers are fitted on connectors
J29_xx and J30_xx located on the front panel of the EXT1-S card (J29_30 for S/T0
access, J29_31 and J30_31 for S/T1 access).
The four accesses are placed vertically on the card. The one at the bottom is the S/T0
access and the one at the top the S/T3 access.
Depending on the position of the jumpers, the S/T0 to S/T3 accesses will be configured
as follows:
• No remote power supply.
• Remote supply of - 48 V.
Figure 4.25 C
Installation and Maintenance Manual - Aastra 5000
Description des sous-ensembles
ONFIGURING REMOTE POWER SUPPLY OF
01/2011
S/T0
S/T3
TO
AMT/PTD/PBX/0058/4/6/EN