Aastra AXD Installation And Maintenance Manual

Aastra AXD Installation And Maintenance Manual

Aastra 5000 server installation and maintenance manual
Table of Contents

Advertisement

AXD - AXL - AXS - AXS12 - AXS6 - Aastra 5000 Server
Installation and Maintenance Manual
AMT/PTD/PBX/0058/4/6/EN
01/2011
Installation and Maintenance Manual - Aastra 5000
AMT/PTD/PBX/0058/4/6/EN
01/2011
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Aastra AXD

  • Page 1 AXD - AXL - AXS - AXS12 - AXS6 - Aastra 5000 Server Installation and Maintenance Manual AMT/PTD/PBX/0058/4/6/EN 01/2011 Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN 01/2011 Page 1...
  • Page 2 AASTRA 1 rue Arnold Schoenberg 78280 Guyancourt - France Tel: +33 1 30 96 42 00 Fax: +33 1 30 96 43 00 www.aastra.com Copyright © AASTRA AMT/PTD/PBX/0058/4/6/ENInstallation and Maintenance Manual - Aastra 5000 Page 2 01/2011 Préliminaires...
  • Page 3: Table Of Contents

    3.1.1 General description of AXD iPBXs ....... . 3.1.1.1 Internal description ........
  • Page 4 Duplication (Aastra XD) ........
  • Page 5 ADS 350XD (AXD iPBX) ........
  • Page 6 Physical description ......... . . AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 6...
  • Page 7 4.12.2.1 Connectors ..........Installation and Maintenance Manual - Aastra 5000...
  • Page 8 4.13.6.9 Hardware configuration ........AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 8...
  • Page 9 4.14.6.1 Description..........Installation and Maintenance Manual - Aastra 5000...
  • Page 10 4.14.14LI1 card ........... . AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 10...
  • Page 11 INSTALLATION AND ACTIVATION....... . . Installation and Maintenance Manual - Aastra 5000...
  • Page 12 Installing an AXD cabinet ........
  • Page 13 Adding an AXD power module ........
  • Page 14 List of interchangeable subassemblies, fuses, batteries, cables and securing kits 398 7.2.7.1 Interchangeable AXD iPBX subassemblies..... . 7.2.7.2 Interchangeable AXS/AXL iPBX subassemblies ....
  • Page 15 10.9.4 Restarting and validating the new version ......10.9.5 Via Aastra Management AM 7450 ....... .
  • Page 16 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 16 01/2011...
  • Page 17 Tableau 3.2 List of AXD iPBX subassemblies ....... . .
  • Page 18 Tableau 4.89 Presentation of the BTX card jumpers ......Tableau 6.1 Options for installing an AXD cabinet .......
  • Page 19 Tableau 7.7 List of optional interchangeable batteries ......Tableau 7.8 List of interchangeable cabinets (AXD iPBX) ......
  • Page 20 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 20 01/2011...
  • Page 21 LIST OF PLATES PLATE 9.1 FUNCTIONAL DIAGRAM OF AN AASTRA XD IN SIMPLEX CONFIGURATION PLATE 9.2 FUNCTIONAL DIAGRAM OF AN AASTRA XD IN DUPLEX CONFIGURATION PLATE 9.3 FUNCTIONAL DIAGRAM OF AN AASTRA XL, XS AND XS12 PLATE 9.4 PRINCIPLE OF MULTI-SITE SYNCHRONISATION Installation and Maintenance Manual - Aastra 5000AMT/PTD/PBX/0058/4/6/EN Préliminaires01/2011...
  • Page 22 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 22 01/2011...
  • Page 23 Rear view of an AXD cabinet ........
  • Page 24 Figure 4.47 Overview of the CS1 card ........AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 24...
  • Page 25 Overview of an exchange sheet (E sheet) ......Installation and Maintenance Manual - Aastra 5000...
  • Page 26 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 26 01/2011...
  • Page 27: Introduction

    • An installation and maintenance manual. The purpose of this document called "Installation and maintenance manual" is to describe Aastra 5000 series products, and provide the information required for their installation and maintenance at 0 level. This document is broken down as follows: •...
  • Page 28: Target Audience For The Document

    • Chapter 9: : Planches This chapter contains the functional maps. • Chapter 10 : Installing Aastra 5000 Server This chapter describes the installation of Aastra 5000 Server. • Chapter 11 : Appendices Certain specific procedures or additional information are contained in this chapter.
  • Page 29: Reference Documents

    [13] Installation and operating manual for SIP access point, NAT and TFTP services AMT/PTD/PBX/0064 [14] Installation manual for redundancy and double attachment on A5000 Server AMT/PTD/PBX/0083 [15] Installation manual Aastra 53xxip and Aastra 67xxi Aastra 53xx sets AMT/PTD/TR/0014 [16] Manuel de Mise en Oeuvre Séparation des Flux téléphonie et Administration AMT/PTD/PBX/0101...
  • Page 30: Abbreviations

    Integrated Services Digital Network ROHS Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment PSTN Public Switched Telephone Network Direct Inward Dialling Single Frame Systems Network Architecture AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 30 01/2011 Introduction...
  • Page 31: Terms And Expressions

    Terms and expressions Aastra X series : This term refers to all AXS, AXL and AXD PBXs. Aastra 5000 or A5000 Server: Telephone switching system hosted on a PC running with Linux Redhat AXS, AXL, AXD: A5000 series physical gateways...
  • Page 32 IPS card Aastra XS, XL and XD expansion card. This card acts like an SIP access point which enables the iPBXs to offer connections to SIP terminals, to alternative SIP operators (SIP trunk), or to remote SIP servers.
  • Page 33 Primary rate S2/T2 ISDN access trunk card or PCM digital trunk card. MUM card Voice / Fax multiplexer/demultiplexer card. PT2 card TCP/IP-X25 and voice over IP gateway card used for connection to a 10/100 Mbits Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Introduction 01/2011 Page 33...
  • Page 34 UCV card Central Processing Unit card of an Aastra XS/XL iPBX. UCV-D card Central Processing Unit card of an Aastra Duplicated iPBX (AXD). CSTA Communication standard enabling telephone and computer applications to communicate in client/server mode. Connection with the server is via either an X25 or TCP/IP link.
  • Page 35 Conversion tools (Version Upgrade). VUs are run to transmit data in the form of a new software packet. Protocol for the connection between a DTE and a DCE, or between two DTEs for transmitting data in packet mode. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Introduction 01/2011...
  • Page 36 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 36 01/2011 Introduction...
  • Page 37: Presentation

    This security guarantees 100% iPBX resources availability. Aastra XD exists in form of one, two or three cabinets used to manage 8 to 1000 extensions. Like the other products, it is based on a single software application and a range of subassemblies common to all Aastra products.
  • Page 38 • 500 physical extensions for an AXS • 500 physical extensions for an AXS12 AXD, AXL, AXS, AXS12 and AXS6 iPBXs can be fitted with a broad range of expansion cards, used to configure the iPBXs optimally in order to meet your needs: •...
  • Page 39: Functional And Physical Architecture Of The Ipbxs

    Functional and physical architecture of the iPBXs 2.2.1 Aastra XD The architecture of Aastra XD is as follows: • A main cabinet including: - one (simplex configuration) or two main UCV-D cards (duplex configuration), the core of the iPBX, mainly perform tasks such as process management, switching and interfacing with the management devices;...
  • Page 40: Aastra Xs/Xl

    Aastra XD accepts only one physical format of expansion cards: a card with a front panel (RJ card) fitted with RJ45 connectors. The CPU card of Aastra XD (UCV-D) exists in a single RJ45 format. All products in the range have the same width (standard 19''), colours and materials.
  • Page 41: Overview Of The Functions

    - operating and supervising the peripheral devices and networks connected to the system, together with Aastra Management Portal - collecting internal or external alarms - managing expansion cards (AXD, AXL, AXS, AXS12 and AXS6 PBXs): Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Présentation...
  • Page 42 - reset and supervision - storing the information and data required for card operations • Managing duplicated services (Aastra XD only): - duplication of power supply (switchover) - duplication of CPU cards: - switchover - duplication of hardware functions - data synchronisation...
  • Page 43: Physical Description

    Physical description 3.1.1 General description of AXD iPBXs An Aastra XD (AXD) iPBX in simplex or duplex configuration consists of one main cabinet and, if necessary, one expansion cabinet (version A2XD) or two expansion cabinets (version A3XD). The main cabinet and expansion cabinets are in the form of a 19" metal cabinet, 10 U, in which the subassemblies required for the iPBX to operate are inserted.
  • Page 44: Internal Description

    RUCV-D card for an expansion cabinet, and the card supporting the external connections and expansion cards. Nota : Fans are fixed on the power supply module and on the ventilation module. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 44 01/2011 Description et caractéristiques d’un PBX...
  • Page 45 UCV-D card (A) Expansion cards BTX card Ventilation module Blanking plate (empty slot) Power supply module Figure 3.1 O VERVIEW OF AN CABINET IN SIMPLEX CONFIGURATION Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 45...
  • Page 46 Earth connection Hot air outlet 4 DB25-F connectors Connection to the expansion cabinet(s) Fresh air inlet Figure 3.2 R EAR VIEW OF AN CABINET AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 46 01/2011 Description et caractéristiques d’un PBX...
  • Page 47 Power supply modul Expansion cards Ventilation module Main rack BTX card Power supply module Figure 3.3 O A2XD VERVIEW OF AN CABINET IN SIMPLEX CONFIGURATION Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 47...
  • Page 48: Figure 3.4 Overview Of An A3Xd Cabinet In Simplex Configuration

    Expansion cards Power supply module Ventilation modu Main rack BTX card Power supply module Figure 3.4 Overview of an A3XD cabinet in simplex configuration AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 48 01/2011 Description et caractéristiques d’un PBX...
  • Page 49: Figure 3.5 Overview Of An Axd Cabinet In Simplex Configuration With Secure Power Unit

    Power supply module (p Blanking plate (empty slot) Power supply module (pow Figure 3.5 Overview of an AXD cabinet in simplex configuration with secure power unit Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011...
  • Page 50: Figure 3.6 Overview Of An A2Xd Cabinet In Simplex Configuration With Secure Power Unit

    (power supply module Main rack BTX card Power supply module (power suppl Figure 3.6 Overview of an A2XD cabinet in simplex configuration with secure power unit AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 50 01/2011 Description et caractéristiques d’un PBX...
  • Page 51: Figure 3.7 Overview Of An A3Xd Cabinet In Simplex Configuration With Secure Power Unit

    Main rack BTX card Power supply module (power supply module 1) Figure 3.7 Overview of an A3XD cabinet in simplex configuration with secure power unit Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 51...
  • Page 52: Figure 3.8 Overview Of An Axd Cabinet In Duplex Configuration

    Power supply module Expansion cards (power supply module 2) Power supply module (power supply module 1) Figure 3.8 Overview of an AXD cabinet in duplex configuration AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 52 01/2011 Description et caractéristiques d’un PBX...
  • Page 53 -D card (A) Power supply module (power supply modu Expansion cards Power supply module (power supply module Main rack BTX card Power supply module (power suppl Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 53...
  • Page 54: Figure 3.9 Overview Of An A3Xd Cabinet In Duplex Configuration

    (power supply module 2) Main rack BTX card Power supply module (power supply module 1) Figure 3.9 Overview of an A3XD cabinet in duplex configuration AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 54 01/2011 Description et caractéristiques d’un PBX...
  • Page 55: General Description Of Axl Ipbxs

    3.1.2 General description of AXL iPBXs An Aastra XL (AXL) iPBX comprises one main cabinet and possibly one (A2XL version) or two (A3XL version) expansion cabinets. The main cabinet and expansion cabinets are in the form of a 19" metal cabinet, 7 U, in which the subassemblies required for the iPBX to operate are inserted.
  • Page 56: Figure 3.10 Overview Of An Axl Cabinet

    UCV-L card Expansion cards Blanking plate Power supply module (empty slot) Figure 3.10 Overview of an AXL cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 56 01/2011 Description et caractéristiques d’un PBX...
  • Page 57: Figure 3.11 Rear View Of An Axl Cabinet

    Expansion cabinet connection cable connector Fresh air inlet Hot air outlet Earth connec- tion Figure 3.11 R EAR VIEW OF AN CABINET Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 57...
  • Page 58: Figure 3.12 Overview Of An A2Xl Cabinet

    Expansion cabinet card UCV-L Connection cable AXL-A2XL Main rack Expansion cards Blanking plates (empty slots) Power supply modules Figure 3.12 Overview of an A2XL cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 58 01/2011 Description et caractéristiques d’un PBX...
  • Page 59: Figure 3.13 Overview Of An A3Xl Cabinet

    UCV-L First expansion cabinet Cards expansion cabinet Main rack Blanking plates (empty slots) Power supply modules Figure 3.13 Overview of an A3XL cabinet Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 59...
  • Page 60: General Description Of Axs Ipbxs

    3.1.3 General description of AXS iPBXs An Aastra XS (AXS) iPBX includes a main cabinet, and possibly an expansion cabinet (A2XS version). The main cabinet and the expansion cabinets are in the form of a 19" metal cabinet, 2 U, in which the subassemblies required for the iPBX to operate are inserted.
  • Page 61: Internal Description

    • The expansion cards can be plugged in along the guides located on the sides of the cabinets. • A power unit connected to the backplane (UCV-S or RUCV-S) • A fan. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011...
  • Page 62: Figure 3.14 Overview Of An Axs Cabinet

    Fresh air inlet Power supply UCV-S card Hot air outlet Expansion card EXT1-S card Figure 3.14 Overview of an AXS cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 62 01/2011 Description et caractéristiques d’un PBX...
  • Page 63: Figure 3.15 Overview Of An A2Xs Cabinet

    RUCV-S UCV-S card Expansion cabinet Main rack Expansion cards EXT1-S card Figure 3.15 Overview of an A2XS cabinet Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 63...
  • Page 64: Figure 3.16 Rear View Of An Axs Cabinet

    Earth connection Fuse holder "I/O" switch Fresh air inlet Expansion cabinet connection with Battery connector expansion cabinet Figure 3.16 Rear view of an AXS cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 64 01/2011 Description et caractéristiques d’un PBX...
  • Page 65: Physical Description Of An Aastra Xs12 Ipbx

    Physical description of an Aastra XS12 iPBX 3.1.5.1 Control keys An Aastra XS12 (AXS12) iPBX includes a main cabinet, and possibly an expansion cabinet (version A2XS12). The main cabinet and the expansion cabinets are in the form of a 19" metal cabinet, 2 U, in which the subassemblies required for the iPBX to operate are inserted.
  • Page 66: Internal Description

    • The expansion cards can be plugged in along the guides located on the sides of the cabinets. • A power unit connected to the backplane (UCV-S or RUCV-S) • A fan. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 66 01/2011 Description et caractéristiques d’un PBX...
  • Page 67: Figure 3.17 Overview Of An Axs12 Cabinet

    Power supply Fresh air inlet Hot air outlet card CV-S12 Expansion card card EXT1-S12 Figure 3.17 Overview of an AXS12 cabinet Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 67...
  • Page 68: Figure 3.18 Rear View Of An Axs12 Cabinet

    Mains socket Earth connection Fuse holder Fresh air inlet "I/O" switch Battery connector Figure 3.18 Rear view of an AXS12 cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 68 01/2011 Description et caractéristiques d’un PBX...
  • Page 69: Physical Description Of An Aastra Xs6 Ipbx

    Physical description of an Aastra XS6 iPBX 3.1.6.1 Control keys An Aastra XS6 (AXS6) iPBX consists of a main cabinet, and possibly an expansion cabinet (version A2XS6). The main cabinet and the expansion cabinets are in the form of a 19" metal cabinet, 2 U, in which the subassemblies required for the iPBX to operate are inserted.
  • Page 70: Internal Description

    • The expansion cards can be plugged in along the guides located on the sides of the cabinets. • A power unit connected to the backplane (UCV-S or RUCV-S) • A fan. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 70 01/2011 Description et caractéristiques d’un PBX...
  • Page 71: Figure 3.19 Overview Of An Axs6 Cabinet

    Power supply Fresh air inlet card UCV-S Hot air outlet Expansion card card EXT1-S6 Figure 3.19 Overview of an AXS6 cabinet Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 71...
  • Page 72: Figure 3.20 Rear View Of An Axs6 Cabinet

    Mains socket Earth connection Fuse holder Fresh air inlet "I/O" switch Battery connector Figure 3.20 Rear view of an AXS6 cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 72 01/2011 Description et caractéristiques d’un PBX...
  • Page 73: Characteristics

    7.5 kg 15 kg (simplex) 18 kg (duplex) without expansion cards and 28 kg in total TABLE 3.1PHYSICAL CHARACTERISTICS OF AXD, AXL, AXS, AXS12, AND AXS6 PBXS 3.2.2 Electrical specifications ADS 350XD power supply module (AXD iPBX) CHARACTERISTICS VALUES Rated voltage...
  • Page 74 ADS 300XD power supply module (AXD iPBX) CHARACTERISTICS VALUES Rated voltage 115 V or 230 V Tolerances +/- 10% Frequency 50 or 60 Hz Power 300 W Converter (48 V) +5 V / 15 A et -5 V / 0,5 A +12 V / 0.5 A and -12 V / 0.65 A...
  • Page 75: Environmental Conditions

    IN OPERATION IN STORAGE Temperature 5 to 40 -10° to 70°C relative humidity 10% to 80 %, without condensation 10% to 95 %, without condensation Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 75...
  • Page 76: Capacity

    Capacity Refer to the product Guide. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 76 01/2011 Description et caractéristiques d’un PBX...
  • Page 77: Simplex With Secure Power

    Physical breakdown 3.4.1 Aastra XD The subassemblies of each of the Aastra XD configurations are presented in a tree in Tableau 3.2 . Nota : The quantities indicated are the maximum hardware and software quantities for each type of card. These quantities also depend on the configuration rules (see Section3.5 ) and engineering rules of each site.
  • Page 78: Duplex

    AXD EXPANSION A2XD A3XD CABINET Simplex Simplex with secure power supply Duplex List of the sub-assemlies in AXD iPBXs - Folio 2 de 6 - AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 78 01/2011 Description et caractéristiques d’un PBX...
  • Page 79: Figure 4.3

    Duplex Simplex Simplex with secure power supply Duplex List of the sub-assemlies in AXD iPBXs - Folio 3 de 6 - Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 79...
  • Page 80 Duplex LN16X Simplex Simplex with secure power supply Duplex LN16X-8 List of the sub-assemlies in AXD iPBXs - Folio 4 de 6 - AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 80 01/2011 Description et caractéristiques d’un PBX...
  • Page 81 Duplex Simplex Simplex with secure power supply Duplex LR4-DTOC List of the sub-assemlies in AXD iPBXs - Folio 5 de 6 - Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 81...
  • Page 82: Aastra Xs/Xl

    If case G is reached (CLX = 10), no other card is accepted in the main cabinet. The LD4, LD4N, LD4X and LT2 synchronising cards must be located in slots 0 to 5 of the AXD main cabinet when they are to be used to provide the carrier (RTCP) reference clocks for the main card.
  • Page 83: Figure 5.3

    The LD4, LD4N, LD4X and LT2 synchronising cards must be located in slots 0 to 5 of the AXL main cabinet when they are to be used to provide the carrier (RTCP) reference clocks for the main card. 1 IPS card maximum per system. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX...
  • Page 84: Axd Ipbxs

    Configuration rules 3.5.1 AXD iPBX 3.5.1.1 AXD main cabinet An AXD iPBX contains 16 slots numbered from 00 to 15, corresponding to the following physical positions: (C) IUCVD (B) UCV-D (RUCV-D) Power supply (A) UCV-D (RUCV-D) module 2 Power supply module 1 TABLEAU 3.4 SLOT NUMBERS ON THE BACKPLANE OF AN AXD IPBX...
  • Page 85: Installation And Maintenance Manual - Aastra 5000

    LR4 Yes LI1 Yes BTX Yes TABLEAU 3.5 POSSIBLE BASIC AXD IPBX BACK PLANE EQUIPMENT CONFIGURATION The LD4, LD4N, LD4X and LT2 synchronising cards must be located in slots 0 to 5 of the main cabinet when they are to be used to provide the reference clocks for the main card.
  • Page 86: A2Xd And A3Xd Expansion Cabinet

    PT2 8,16,32 channels Equipment cards LA16X LA16X-8 LN16X LN16X-8 LH16X LH16X-8 TABLEAU 3.6 POSSIBLE CONFIGURATIONS OF THE TWO EXPANSION BACKPLANES OF AN AXD IPBX AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 86 01/2011 Description et caractéristiques d’un PBX...
  • Page 87: Ucv

    3.5.2.1 AXL main cabinet The following table presents the possible slots, as well as the restrictions concerning the various Aastra XS/XL range expansion cards of the main cabinet: Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX...
  • Page 88: Clx Cards

    The LD4, LD4N, LD4X and LT2 synchronising cards must be located in slots 0 to 5 of the main cabinet when they are to be used to provide the reference clocks for the main card. TABLEAU 3.8 POSSIBLE BASIC AXL IPBX BACK PLANE EQUIPMENT CONFIGURATION AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 88 01/2011 Description et caractéristiques d’un PBX...
  • Page 89: Ips (2)

    PT2, LD4, LD4N for slots 00 to 05. - Full list: IPS, 32- LA16X, LN16X, LA16X-8, LN16X-8, LH16X, LH16X-8, CS1, CA1, channel PT2, LT2, BTX. LD4X, 0-channel PT2 0. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 89...
  • Page 90: Mum 10 10 10 3 3 3

    PT2 8,16,32 channels Equipment cards LA16X LA16X-8 LN16X LN16X-8 LH16X LH16X-8 TABLEAU 3.9 POSSIBLE CONFIGURATIONS OF THE TWO EXPANSION BACKPLANES OF AN AXL IPBX AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 90 01/2011 Description et caractéristiques d’un PBX...
  • Page 91: Axs/Axs12/Axs6 Ipbx

    TABLEAU 3.10 SLOT NUMBERS ON THE BACKPLANE OF AN AXS/AXS12/AXS6 IPBX The slots in a main cabinet can be fitted with all the Aastra X series cards. The slots in an expansion cabinet can only be fitted with equipment cards.
  • Page 92: I-Button Dongle And Software Locking

    A removable "i-Button" dongle (circuit in a metal box, similar to a battery) on the UCV (AXS/AXL) and IUCV-D (AXD) main card contains the iPBX identification number (this number can be displayed when the cabinet is started or via MMC). This number is used for unlocking optional software functions.
  • Page 93: Command And Processing Unit

    Command and processing unit The command and processing unit chain is ensured by the main card. It manages the following features: • Duplex and start logic (Aastra XD only) • Data and voice switching • Signal processing • Voice mail server •...
  • Page 94: Duplex And Start Logic Function (Aastra Xd Only)

    The TSs are exchanged between the various subassemblies of the iPBX over a synchronous bus. 3.8.1.2 Duplex and start logic function (Aastra XD only) Duplex logic The main function of the duplex logic is to determine which of the two UCV-D cards of a duplex system is active (see Section 3.8.2).
  • Page 95: Voice Mail Server Function

    • Prompts the voice mail server to broadcast a message, announcement or music • Supervises the various expansion cards through the asynchronous system bus. 3.8.1.7 Synchronisation function See 3.8.4 Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 95...
  • Page 96: Connection To The Communication Networks And Terminals

    - a synchronous bus, the equipment bus, for conveying the voice or data information through PCM TSs - an asynchronous system bus, for exchanging their status and command AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 96 01/2011 Description et caractéristiques d’un PBX...
  • Page 97: Duplication (Aastra Xd)

    • Duplication of UCV-D cards: two UCV-D CPU cards (duplex configuration) can be fitted in the Aastra XD main cabinet. A single card is enough to run the entire system. In a duplex configuration, one UCV-D card is active and the other passive. Interfaces with the system bus and the equipment bus of both UCV-D cards are connected together to the back plane.
  • Page 98 This synchronisation guarantees service continuity after switchover, for the following functions: • active software release, system and application • digital set languages and MMC languages AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 98 01/2011 Description et caractéristiques d’un PBX...
  • Page 99 Power supply duplication Aastra XD can receive two ADS 350XD or ADS 300XD power sypply modules (simplex configuration with secure power supply and duplex configuration) in the same cabinet (main cabinet and expansion cabinets), see Section 3.8.6. Both ADS350XD and ADS300XD in the same cabinet is not possible.
  • Page 100: Synchronisation Chain (Plate 9.1)

    These LT2, LD4, LD4N and LD4X cards must be fitted in slots 0 to 5 in the main cabinet of the AXL and AXD iPBXs (slots 0 to 2 for AXS). All the EXT1-S ISDN accesses are synchronising. The first active digital network card synchronises the system. It maintains this as long as its clock is valid, and in the absence of higher priority clocks.
  • Page 101: Management Of The Master/Slave Mode (Multisite Network)

    3.8.4.2 Management of the master/slave mode (multisite network) For a multisite network with DECT base stations, the various Aastra XS/XL/XD iPBXs require the same synchronisation signal. Nota : The AXS12 iPBX allows multi-site DECT synchronisation through the wiring of a third pair on the base stations.
  • Page 102: Defence Chain

    The defence chain is provided by the various subassemblies fitted in the iPBX. Its role is to advise the operator of malfunctions of one or more items. It includes the following functions: • Monitoring • Alarm analysis • Self-protection. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 102 01/2011 Description et caractéristiques d’un PBX...
  • Page 103: Monitoring

    • Recording of an action report message in the log. The status of the subassemblies, centralised by the main card, can be viewed and managed with the AMP, in the log. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX...
  • Page 104: Self Protection

    3.8.6 Power supply chain (figure 3.23) 3.8.6.1 Aastra XD Aastra XD cabinets are powered by one or two plug-in power supply units (type ADS350XD or ADS300XD). Both ADS350XD and ADS300XD in the same cabinet is not possible. Caution : • In a simplex configuration with secure power supply and in a duplex configuration, each cabinet is power up by two power supply units.
  • Page 105 A converter inside the power supply module converts the 48 V power supply generated by the battery or rectifier to the low voltages required by the various subassemblies of the iPBX. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX...
  • Page 106 EXPANSION CARDS P.sup Alarms P.sup VENTILATION P.sup MODULE Figure 3.21 B LOCK DIAGRAM OF THE POWER SUPPLY CHAIN IN AN CABINET IN SIMPLEX CONFIGURATION AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 106 01/2011 Description et caractéristiques d’un PBX...
  • Page 107 P.sup POWER SUPPLY MODULE Figure 3.22 B LOCK DIAGRAM OF THE POWER SUPPLY CHAIN IN AN CABINET IN DUPLEX CONFIGURATION Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 107...
  • Page 108: Aastra Xs/Xl

    The mains is distributed to the power supply module's rectifier through: • A mains switch used to power the supply module on or off • Two fuses. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 108 01/2011 Description et caractéristiques d’un PBX...
  • Page 109: Figure 3.23 Block Diagram Of The Power Supply Chain In An Axl Cabinet

    Figure 3.23 B LOCK DIAGRAM OF THE POWER SUPPLY CHAIN IN AN CABINET Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 109...
  • Page 110: Figure 3.24 Block Diagram Of The Power Supply Chain In An Axs Cabinet

    Figure 3.24 Block diagram of the power supply chain in an AXS cabinet AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 110 01/2011 Description et caractéristiques d’un PBX...
  • Page 111: Figure 3.25 Block Diagram Of The Power Supply Chain On An Axs12/Axs6 Cabinet

    Figure 3.25 Block diagram of the power supply chain on an AXS12/AXS6 cabinet Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 111...
  • Page 112: Internal Monitoring Of Axs/Axl/Axd

    When an iPBX has several cabinets, a battery is available for each cabinet. However, the same battery can be connected at the same time on the 2 or 3 cabinets of an AXD or AXL or the 2 cabinets of an AXS. In this case, check that the battery can withstand the charging current (2A per ADS300XD/ADS350XD power unit for charging the battery, 6A per ADS300X/ADS350XD (AXL) power unit and 3 A per ADS150X (AXS) power unit).
  • Page 113: Figure 3.26 Connecting A Battery Pack In Parallel To An A3Xd Ipbx

    (1) Do not connect an AXL iPBX and an AXS iPBX to the same battery pack. Attention : (2) Do not connect an AXD iPBX and another Aastra iPBX (for instance AXL or AXS) to the same battery pack. 38AH...
  • Page 114: Figure 3.27 Connecting A Battery Pack In Parallel To An A3Xl Ipbx

    38AH 38AH 38AH 38AH Figure 3.27 C A3XL ONNECTING A BATTERY PACK IN PARALLEL TO AN AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 114 01/2011 Description et caractéristiques d’un PBX...
  • Page 115: Figure 3.28 Connecting A Battery Pack In Parallel To An A2Xd Ipbx

    Battery autonomy 3 h 30 mn TABLEAU 3.14 A2XD OR AXL IPBX BATTERY CHARACTERISTICS (1) Do not connect an AXD iPBX and another Aastra iPBX (for instance AXL or AXS) to Attention : the same battery pack. (2) Do not connect an AXL iPBX and an AXS iPBX to the same battery pack.
  • Page 116: Figure 3.29 Connecting A Battery Pack In Parallel To An A2Xl Ipbx

    24AH 24AH 24AH 24AH Figure 3.29 C A2XL ONNECTING A BATTERY PACK IN PARALLEL TO AN AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 116 01/2011 Description et caractéristiques d’un PBX...
  • Page 117: Figure 3.30 Connecting A Battery Pack In Parallel To An A2Xs Ipbx

    Do not connect an AXL iPBX and an AXS iPBX to the same battery pack. Attention : Figure 3.30 C A2XS ONNECTING A BATTERY PACK IN PARALLEL TO AN Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX 01/2011 Page 117...
  • Page 118: Ventilation

    The iPBX has a default configuration when it leaves the factory (default configuration also obtained after a total reset). The system is fully functional and only requires a few adjustments after initialisation to be completely operational. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 118 01/2011 Description et caractéristiques d’un PBX...
  • Page 119: Standard Configuration

    • Management of DID (Direct Inward Dialling) specifically suited to patients • The do not disturb function for patients during the night • Charging according to patient downpayments. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description et caractéristiques d’un PBX...
  • Page 120: The User Interface

    The user interface The user interface is a PC, running with Windows (2000, XP, ..) or Linux, fitted with web browser (such as Internet Explorer, Filezilla ) for accessing Aastra Management Portal (AMP), see Section 6.2.6. This console can be connected: •...
  • Page 121: Description Des Sous-Ensembles

    4.1.1 DescriptionDescription des sous-ensembles Aastra XS/XL/XD expansion cards exist in RJ45 physical format, a format fitted with a front panel for RJ45 connectors. These cards are called "RJ cards". The dimensions of the cards (Lx16-X) are 280 mm in depth and 100 mm in width.
  • Page 122: Figure 4.1 Procedure For Locking A Card Or Blanking Plate

    Carte verrouillée Pivoter d'1/4 de tour vers l'extérieur Carte déverrouillée Figure 4.1 P ROCEDURE FOR LOCKING A CARD OR BLANKING PLATE AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 122 01/2011 Description des sous-ensembles...
  • Page 123: Loading Clx Cards

    • The flash memory on CLX cards contain the start-up software; an image of the application software can be inserted, installed, etc. on it. • They can be fully loaded during an update using a BOF3 card (see section1.3, Document [3]). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011...
  • Page 124: Power Supply Module

    ADS 350AXD is the power supply module of the main cabinet and expansion cabinet of an AXD iPBX. It replaces the ADS300XD module, and offers extra 50 W and an enhanced cooling system (a plate has been added to the left side).
  • Page 125: Monitoring

    The maximum height of the components above the PCB is 70 mm. An "I/O" switch on the front panel is used to power the supply on and off. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 126: Hardware Configuration

    TABLEAU 4.1 PRESENTATION OF ADS 350XD POWER SUPPLY MODULE INDICATORS 4.2.1.5 Hardware configuration The mains voltage, 115 V or 230V (+/- 10%), is detected automatically, internally. 4.2.1.6 Installation and wiring AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 126 01/2011 Description des sous-ensembles...
  • Page 127: Ads 300Xd (Axd Ipbx)

    4.2.2.1 Description ADS 300AXD is the power supply module of the main cabinet and expansion cabinet of an AXD iPBX. Depending on the Aastra XD configuration, power is supplied to the cabinets through one or two power supply modules: ADS300XD •...
  • Page 128: Monitoring

    On/Off sequence. Internal F300 fuse Indicators Fans "I/O" switch Fuse holder Mains socket Securing screw Figure 4.3 O ADS300 XD VERVIEW OF THE MODULE AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 128 01/2011 Description des sous-ensembles...
  • Page 129: Physical Description (Figure 4.3 )

    TABLEAU 4.2 PRESENTATION OF ADS 300XD POWER SUPPLY MODULE INDICATORS 4.2.2.5 Hardware configuration The mains voltage, 115 V or 230V +/- 10%), is detected automatically, internally. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 129...
  • Page 130: Installation And Wiring

    115 V or 230 V (+/- 10%) mains, 50 Hz or 60 Hz, without configuration, • two fans supplied by the converter 12V DC voltage draw air towards the rear of the cabinet. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 130 01/2011 Description des sous-ensembles...
  • Page 131: Figure 4.4 Overview Of The Ads 350X Module

    When the 2 fans are detected as stopped simultaneously, the power supply is cut off automatically; restarting is possible only through an On/Off sequence. Figure 4.4 OVERVIEW OF THE ADS 350X MODULE Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 132: Physical Description (Figure 4.5 )

    The ADS 350X is fitted with 2 80mm diameter fans located at the back of the power supply module. Connectors The front panel of the power supply module has: • A mains socket • A 4-pin battery connector AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 132 01/2011 Description des sous-ensembles...
  • Page 133: Hardware Configuration

    The ADS 350X power supply module is supplied with a battery connection cable fitted with a 4 pin connector, with a centring piece to prevent polarity inversion when connecting the backup battery. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 134: Ads 300X (Axl Ipbx)

    115 V or 230 V (+/- 10%) mains, 50 Hz or 60 Hz, without configuration, • two fans supplied by the converter 12V DC voltage draw air towards the rear of the cabinet. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 134 01/2011 Description des sous-ensembles...
  • Page 135: Figure 4.5 Overview Of The Ads 300X Module

    On/Off sequence. 40V ISDN Internal F300 fuse Fans Battery connector "I/O" switch Fuse holder Mains socket Securing screw Figure 4.5 OVERVIEW OF THE ADS 300X MODULE Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 135...
  • Page 136: Physical Description (Figure 4.5 )

    Connectors The front panel of the power supply module has: • A mains socket • A 4-pin battery connector • An RJ45 40 V ISDN connector. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 136 01/2011 Description des sous-ensembles...
  • Page 137: Hardware Configuration

    The ADS 300X power supply module is supplied with a battery connection cable fitted with a 4 pin connector, with a centring piece to prevent polarity inversion when connecting the backup battery. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 138: Ads 150X (Axs And Axs12 Ipbxs)

    On/Off sequence. 4.2.5.4 Physical description ADS 150X (see Figure 3.14 ) is a card 90 mm wide and 410 mm long. The height of the AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 138 01/2011 Description des sous-ensembles...
  • Page 139: Hardware Configuration

    The ADS 150X power supply module comes with a connection cable fitted with a 4 pin connector, with a centring piece to prevent polarity inversion when connecting the backup battery. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 140: Ucv-D Card

    • The UCV-D card can be fitted with two EIP daughter cards for managing VoIP communications. These two daughter cards have 8/32 channels each for signal processing. Note: The UCV-D card is compatible with the ROHS Directive. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 140 01/2011 Description des sous-ensembles...
  • Page 141 J14: EIP card No. 2 J13: EIP card No. 1 Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 141...
  • Page 142: Figure 4.6 Overview Of The Ucv-Dcard

    Figure 4.6 O UCV-D VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 142 01/2011 Description des sous-ensembles...
  • Page 143: Physical Description

    CTI, TWP mode) can be • Pin 7: RLBR connected directly to the • Pin 8: RLBR LAN port. Connector front view. TABLEAU 4.5 DESCRIPTION OF UCV-D CARD CONNECTORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 143...
  • Page 144 (refer to Manual AMT/PTD/PBX/0101). • Pin 6: TXM • Pin 7: RLBR • Pin 8: RLBR Connector front view. TABLEAU 4.5 DESCRIPTION OF UCV-D CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 144 01/2011 Description des sous-ensembles...
  • Page 145: Indicators

    Note: The "OP" and "ACT" indicators are useful in a duplex configuration. In a simplex configuration, these indicators are always on (green) when the card is operational. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 145...
  • Page 146: Hardware And Software Configuration

    The built-in battery is still in circuit (no microswitch). 4.3.4 Installation and wiring The UCV-D card can be hot-plugged/removed in an operational AXD iPBX. After a switchover the duration of which depends on the configuration (15 Warning: s. to 1 min.), the passive CPU card takes over and becomes active in the following three cases: •...
  • Page 147 The unavailability time on the cabinet can, therefore, be up to 3 minutes). The equipment connected to the UCV-D card has the installation details described in Section 5.6: Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011...
  • Page 148: Figure 4.7 Iucv-D Interface Between Two Ucv-D Cards

    • Four alarm inputs and four relays (3 remote control relays + one “watchdog” alarm relay). For a duplex configuration, the main cabinet of an AXD is fitted with two UCV-D cards. The two UCV-D cards (active and passive) communicate through the iUCV-D card.
  • Page 149 Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 149...
  • Page 150: Figure 4.8 Overview Of The Iucv-Dcard

    Figure 4.8 O IUCV-D VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 150 01/2011 Description des sous-ensembles...
  • Page 151: Physical Description

    4.4.2 Physical description Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 151...
  • Page 152: Connectors

    Pin 6: GNDL ETM: external source present. • Pin 7: MUSB • Pins 1 and 8: NC Connector front view. TABLEAU 4.7 DESCRIPTION OF IUCV-D CARD CONNECTOTRS (1/2) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 152 01/2011 Description des sous-ensembles...
  • Page 153 Pins 20 to 25: NC RJ45 connector: reserved for the manufacturer. Connector front view Tableau 4.9 gives details about command relays. TABLEAU 4.8 DESCRIPTION OF IUCV-D CARD CONNECTORS (2/2) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 153...
  • Page 154 R1: switching relay R2: alarm relays (assignment of alarms by MMC) R3: reduced service relay R4: "Watchdog" alarm connection ofacommon bell Figure 4.9 CARD RELAY CONTACTS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 154 01/2011 Description des sous-ensembles...
  • Page 155: Figure 4.10 Presentation Of Iucv-D Card Indicators

    (rapidly) DECT Active synchronisation master iPBX (green) Slave or Master iPBX TABLEAU 4.10 PRESENTATION OF IUCV-D CARD INDICATORS Figure 4.10 P IUCV-D RESENTATION OF CARD INDICATORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 155...
  • Page 156: Hardware And Software Configuration

    During operation, the IUCV-D card does not have any hardware configuration. 4.4.4 Installation and wiring The IUCV-D card can be hot-plugged/removed in an operational AXD iPBX. The equipment connected to the -D card has the installation details described in IUCV Section 5.6:...
  • Page 157: Rucv-D Card

    (green) ACT (green) ON green Card active Card not active TABLEAU 4.12 OVERVIEW OF RUCV-D CARD INDICATORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 157...
  • Page 158: Figure 4.11 Overview Of The Rucv-Dcard

    Figure 4.11 O RUCV-D VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 158 01/2011 Description des sous-ensembles...
  • Page 159: Figure 4.12 Colour Code For Connection To The Expansion Cabinet(S)

    RUCV-D card (see RUCV-D reference in Tableau 7.1 ). A colour code is indicated at the back of the AXD cabinets to facilitate connection to the expansion cabinet(s). The XD column shows the connection of cables to the main cabinet.
  • Page 160: Figure 4.13 Connecting An Expansion Cabinet

    4.5.4.1 Connecting an expansion cabinet (A2XD) • Simplex configuration: connecting UCV-D (A) / RUCV-D (A) (see Figure 4.13 ) - Install the red clamps at each end of the AXD-A2XD connection cable. 2XD 3XD 2XD 3XD B-2XD B-2XD B-3XD B-3XD...
  • Page 161: Figure 4.15 Connecting An Expansion Cabinet (Duplex Configuration)

    - UCV-D (A) / -D (A) connection RUCV - Install the red clamps at each end of the AXD-A2XD connection cable. - UCV-D (B) / RUCV-D (B) connection - Install the yellow clamps at each end of the AXD-A2XD connection cable.
  • Page 162 • Simplex configuration: connecting UCV-D (B) / RUCV-D (B) (see Figure 4.17 ) - Install the yellow clamps at each end of the AXD-A2XD connection cable. - Install the blue clamps at each end of the AXD-A3XD connection cable. 2XD 3XD...
  • Page 163: Figure 4.16 Connecting Two Expansion Cabinets (Simplex Configuration, Ucv-D(A)/Rucv-D(A))161 Figure 4.17 Connecting Two Expansion Cabinets (Simplex Configuration, Uct-D(B)-Ruct-D(B))162 Figure 4.18 Connecting Two Expansion Cabinets (Duplex Configuration)

    • Duplex configuration: (see Figure 4.18 ). - UCV-D (A) / RUCV-D (A) connection - Install the red clamps at each end of the AXD-A2XD connection cable. - Install the green clamps at each end of the AXD-A3XD connection cable.
  • Page 164: Ucv-L Card

    • The VMAIL function is directly on the CPU card. A quota of compact flash disk space is assigned to this function to store messages and prompts. Daughter cards AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 164 01/2011 Description des sous-ensembles...
  • Page 165 • The UCV-L card can be fitted with two EIP daughter cards for managing VoIP communications. These two daughter cards have 8/32 channels each for signal processing. Note: The UCV-L card is compatible with the ROHS Directive. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 165...
  • Page 166: Figure 4.19 Overview Of The Ucv-L Card

    BATTE- CARD COMPACT FLASH J14: EIP card No. J13: EIP card No. i-Button. Figure 4.19 O UCV-L VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 166 01/2011 Description des sous-ensembles...
  • Page 167: Physical Description

    Pin 1: PWR1 • Pin 2: DNEG1 • Pin 3: DPOS1 • Pin 4: GND Connector front view. TABLEAU 4.13 DESCRIPTION OF UCV-L CARD CONNECTORS (1/3) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 167...
  • Page 168 Pin 4: NHDECT2 • Pin 5: PHDECT2 • Pin 6: PHBIT2 • Pins 7 and 8: L0V Connector front view TABLEAU 4.14 DESCRIPTION OF UCV-L CARD CONNECTORS (2/3) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 168 01/2011 Description des sous-ensembles...
  • Page 169 Pin 3: RXA • Pin 4: GND Connector front view. Table 4.3 gives the details relating to the command relays. TABLEAU 4.15 DESCRIPTION OF UCV-L CARD CONNECTORS (3/3) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 169...
  • Page 170 The R1 Remote control relay delivers a +12V voltage through an 8 Ohm CTP The R2, R3 and R4 relays deliver +12V through a 25 Ohms CTP. TABLEAU 4.16 DESCRIPTION OF UCV CARD RELAYS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 170 01/2011 Description des sous-ensembles...
  • Page 171: Figure 4.20 Ucv Card Relay Contacts

    The relay positions shown are the inactive states. R1: switching relay alarm relay (assignment by MMC) R3: reduced service relay R4: "watchdog" alarm connection of common bell Figure 4.20 UCV CARD RELAY CONTACTS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 171...
  • Page 172: Indicators

    Link not set up. ON green Link set up at 100 Mb/s. ON yellow Link set up at 10 Mb/s. TABLEAU 4.17 PRESENTATION OF UCV-L CARD INDICATORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 172 01/2011 Description des sous-ensembles...
  • Page 173: Figure 4.21 Presentation Of Ucv-Lcard Indicators

    • An "RST" pushbutton for resetting the iPBX • A "SHTD" (shutdown) push button: Same procedure as for AXD, AXL and AXS/AXS12. From the buttons on the CPU card front panel, you have to distinguish between two types of restart operations: •...
  • Page 174: Installation And Wiring

    The equipment connected to the UCV-L card has the installation details described in Section 5.6: • Operating console • External music source • Common bell (on R3 relay) • Alarm bell (on R2 relay) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 174 01/2011 Description des sous-ensembles...
  • Page 175: Ucv-S Cards

    • The UCV-S card can be fitted with two EIP daughter cards for managing VoIP communications. These two daughter cards have 8/32 channels each for signal processing. Note: The UCV-S card is compatible with the ROHS Directive. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 175...
  • Page 176: Figure 4.22 Overview Of The Ucv-S Card

    BATTERY COMPACT FLASH1 J14: EIP CARD NO. 2 J13: EIP CARD NO. 1 I-BUTTON. Figure 4.22 O VERVIEW OF THE UCV S CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 176 01/2011 Description des sous-ensembles...
  • Page 177: Physical Description

    Pin 1: PWR1 • Pin 2: DNEG1 • Pin 3: DPOS1 • Pin 4: GND TABLEAU 4.18 DESCRIPTION OF UCV-S CARD CONNECTORS (1/3) NAME FUNCTIONS/CHARACTERISTICS CONTACTS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 177...
  • Page 178 Pin 6: RXM • Pin 7: RLBR connected directly to this 10/ • Pin 8: RLBR 100-TX LAN port. TABLEAU 4.19 DESCRIPTION OF UCV-S CARD CONNECTORS (2/3) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 178 01/2011 Description des sous-ensembles...
  • Page 179 Pin 4: GND Connector front view. Tableau 4.16 and Figure 4.20 give the details relating to the command relays. TABLEAU 4.20 DESCRIPTION OF UCV-S CARD CONNECTORS (3/3) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 179...
  • Page 180: Indicators

    Correct synchronisation clock (primary network or DECT port) (green/red) Synchronisation clock fault alarm ON red No correct synchronisation clock (primary network or DECT port) TABLEAU 4.21 PRESENTATION OF UCV-S CARD INDICATORS (1/2) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 180 01/2011 Description des sous-ensembles...
  • Page 181: Figure 4.23 Presentation Of Ucv-S Card Indicators

    From the buttons on the CPU card front panel, you have to distinguish between two types of restart operations: • Restart with OS reboot (shutting down and restarting the iPBX) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 182 Forced restart (not recommended in normal operation) Press "RST". This button should only be used as last resort if pressing the "SHTD" button does not work. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 182 01/2011 Description des sous-ensembles...
  • Page 183: Hardware And Software Configuration

    4.7.3 Hardware and software configuration The following configurations are performed by MMC from Aastra Management Portal: • configuration of the T lines, S or DECT terminal. • Master/Slave mode of the synchronisation port (by default set to Master). • Priority/Non Priority mode of the synchronisation port (by default set to Priority).
  • Page 184: Ext1-S Card

    ISDN ports integrated into the card (S/T0 to S/T3). See the description of the ADPCM16V daughter card in Section 4.13.2.2. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 184 01/2011 Description des sous-ensembles...
  • Page 185: Figure 4.24 Overview Of The Ext1-Scard

    Figure 4.24 O EXT1-S VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 185...
  • Page 186: Physical Description

    Pins 1, 2, 3, 6, 7, and 8: NC Connector front view. Tableau 4.16 and Figure 4.20 give the details relating to the command relays. TABLEAU 4.23 DESCRIPTION OF EXT1-S CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 186 01/2011 Description des sous-ensembles...
  • Page 187: Figure 4.25 Configuring Remote Power Supply Of S/T0 To S/T3 Accesses

    Depending on the position of the jumpers, the S/T0 to S/T3 accesses will be configured as follows: • No remote power supply. • Remote supply of - 48 V. Figure 4.25 C S/T0 S/T3 ONFIGURING REMOTE POWER SUPPLY OF ACCESSES Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 187...
  • Page 188: Figure 4.26 Connecting A Dect Base Station To An S0 Interface Of The Ext1-S Card

    1 ere méthode : utilisation d'un câble croisé méthode : utilisation d'un adaptateur Figure 4.26 C DECT EXT1-S ONNECTING A BASE STATION TO AN INTERFACE OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 188 01/2011 Description des sous-ensembles...
  • Page 189 Pin 3 (ED1) Pin 4 Pin 5 (NRD1) Pin 6 Pin 4 (RD1) Pin 3 TABLEAU 4.24 S0 INTERFACE LINK WITH DECT BASE STATION (TWISTED CABLE) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 189...
  • Page 190: Hardware And Software Configuration

    4.8.4 Hardware and software configuration The following configurations are performed by MMC from Aastra Management Portal: • configuration of the T lines, S or DECT terminal. • Master/Slave mode of the synchronisation port (by default set to Master). • Priority/Non Priority mode of the synchronisation port (by default set to Priority).
  • Page 191: Ext1-S12 Card

    • The EXT1-S12 card can receive an ADPCM16V daughter card which offers the 4- channel base station function on the ISDN ports integrated into the card (S/T0 to S/T3). See the description of the ADPCM16V daughter card in Section 4.13.2.2. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 192: Figure 4.27 Overview Of The Ext1-S12 Card

    Figure 4.27 O EXT1-S12 VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 192 01/2011 Description des sous-ensembles...
  • Page 193: Physical Description

    Tableau 4.16 and Figure 4.20 give the details relating to the command relays. TABLEAU 4.25 DESCRIPTION OF EXT1-S12 CARD CONNECTORS 4.9.2.2 Indicators The EXT1-S12 card does not have any indicators on the front panel. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 193...
  • Page 194: Figure 4.28 Configuring Remote Power Supply Of S/T0 To S/T3 Accesses

    ONFIGURING REMOTE POWER SUPPLY OF ACCESSES 4.9.3.1 Installation and wiring The A0 to A7 interfaces of the EXT1-S12 card have installation details identical to those of AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 194 01/2011 Description des sous-ensembles...
  • Page 195 The S/T accesses of the EXT1-S12 card are wired in T. To connect S Caution: peripherals (S sets or DECT base stations), a twisted cable or S0/T0 adaptor (see Figure 4.26 ) is, therefore, required. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011...
  • Page 196: Figure 4.2

    Pin 3 (ED1) Pin 4 Pin 5 (NRD1) Pin 6 Pin 4 (RD1) Pin 3 TABLEAU 4.26 S0 INTERFACE LINK WITH DECT BASE STATION (TWISTED CABLE) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 196 01/2011 Description des sous-ensembles...
  • Page 197: Figure 4.30 Overview Of The Ext1-S6 Card

    ISDN ports integrated into the card (S/T0 to S/T1). See the description of the ADPCM16V daughter card in Section 4.13.2.2. Figure 4.30 O EXT1-S6 VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 197...
  • Page 198: Physical Description

    Tableau 4.16 and Figure 4.20 give the details relating to the command relays. TABLEAU 4.27 DESCRIPTION OF EXT1-S6 CARD CONNECTORS 4.10.2.2 Indicators The EXT1-S6 card does not have any indicators on the front panel. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 198 01/2011 Description des sous-ensembles...
  • Page 199: Figure 4.31 Configuring Remote Power Supply Of S/T0 To S/T3 Accesses

    4.10.3.1 Installation and wiring The A0 to A3 interfaces of the EXT1-S6 card have installation details identical to those of the interfaces of the LA16X card (see Section 4.14.1.5). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 200 The S/T accesses of the EXT1-S6 card are wired in T. To connect S Caution: peripherals (S sets or DECT base stations), a twisted cable or S0/T0 adaptor (see Figure 4.26 ) is, therefore, required. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 200 01/2011 Description des sous-ensembles...
  • Page 201: Figure 4.32 Connecting A Dect Base Station To An S0 Interface Of The Ext1-S6 Card

    Pin 3 (ED1) Pin 4 Pin 5 (NRD1) Pin 6 Pin 4 (RD1) Pin 3 TABLEAU 4.28 S0 INTERFACE LINK WITH DECT BASE STATION (TWISTED CABLE) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 201...
  • Page 202: Rucv-L Card

    LVDS expansion bus. 8-pin male HE14 Programming the flash memory containing the code to be loaded on FPGA. TABLEAU 4.29 DESCRIPTION OF RUCV-L CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 202 01/2011 Description des sous-ensembles...
  • Page 203: Indicators

    (front panel) TABLEAU 4.30 DESCRIPTION OF RUCV-L CARD INDICATORS 4.11.3 Hardware and software configuration This card does not require any hardware or software configuration. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 203...
  • Page 204: Installation And Wiring

    4.11.4 Installation and wiring Connecting an RUCV-L card to a UCV-L card requires a specific cable supplied with the expansion cabinet ("Y" cable, HG4784). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 204 01/2011 Description des sous-ensembles...
  • Page 205: Figure 4.33 Overview Of The Rucv-Lcard

    Figure 4.33 O RUCV-L VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 205...
  • Page 206: Rucv-S Card

    4.12.2.2 Indicators INDICATOR STATE EXPLANATION LINK flashing green Correct clock received on the LVDS expansion bus (front panel) flashing No clock (UCV stopped or cable disconnected) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 206 01/2011 Description des sous-ensembles...
  • Page 207: Hardware And Software Configuration

    Note: The basic cabinet does not have any internal connector for the inter-cabinet wire. Therefore, the expansion ribbon (delivered with the expansion cabinet) must be connected to basic cabinet. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 208: Figure 4.34 Overview Of The Rucv-Scard

    Figure 4.34 O RUCV-S VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 208 01/2011 Description des sous-ensembles...
  • Page 209: Application Cards (Clx)

    -48 V is provided by the iPBX backplane, while the 40 V ISDN is connected via connector The card also receives the +5 V supply voltage on the backplane connector (J1), used for the operation of its internal circuits. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 210: Figure 4.35 Overview Of The Ld4 Card

    "On Site" J5 and J6 Two connectors AMP CMS 2 x 10 female pins: host the ADPCM4V daughter cards. Male 3-pin connector partially equipped. not used AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 210 01/2011 Description des sous-ensembles...
  • Page 211 Indicators:The indicators are located on the card circuit and not on the front panel. NAME STATE EXPLANATION CR2 (red) Flashing rapidly Card in service TABLEAU 4.35 PRESENTATION OF THE LD4 CARD INDICATORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 211...
  • Page 212: Hardware Configuration

    • SW3: remote power supply interface 3 • SW4: remote power supply interface 2 • SW5: remote power supply interface 1 • SW6: remote power supply interface 0 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 212 01/2011 Description des sous-ensembles...
  • Page 213: Figure 4.36 Wiring The T0 Interface Of An Ld4 Card

    One end of the connection cable must be fitted with an ISO 8877 compliant male RJ45 connector.The minimum diameter of the cables has to be 26AWG (0.4mm). Câble point à point standard Figure 4.36 WIRING THE T INTERFACE OF AN CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 213...
  • Page 214: Figure 4.37 Wiring An S0 Bus

    (BRI) terminal. Long bus (point to point) connecteur 1 PABX connecteur comportant les résistances d'adaptation du bus (100 Ohms, 1/4W) jusqu'à 800 m Figure 4.37 WIRING AN AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 214 01/2011 Description des sous-ensembles...
  • Page 215: Figure 4.38 Connecting A Dect Base Station To An Ld4 Card

    Pin 6 Pin 3 (RD) Pin 3 Pin 5 (NED) Pin 5 Pin 4 (ED) Pin 4 TABLEAU 4.38 S0 INTERFACE LINK WITH DECT BASE STATION Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 215...
  • Page 216: Description Of The Signal Processing Daughter Card

    The card is installed on connectors J5 and J6 of the ISDN interface cards (LD4, LD4N and LD4X) as well as connectors J29 and J30 of EXT1-S, EXT1-S12 and EXT1-S6 cards. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 216 01/2011...
  • Page 217: Ld4Nx Card

    • The card’s hardware information can be read through the MMC (presence of an EEPROM on the card). • It is possible to declare up to10 cards in an Aastra XL. • It is possible to read the status of the card’s remote power supply once the card is in service.
  • Page 218 M bit in the S frame to the base station every 5 ms. The slave base station does not use this synchronization; it uses only the 800ms clock transmitted by the master base station via the third pair. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 218 01/2011 Description des sous-ensembles...
  • Page 219: Figure 4.39 Overview Of The Ld4Nx Card

    CA1.1 = OFF H non validée CA1.2 = non câblé LD4NX CARD LD4NX Console LD4NX CARD FRONT PANEL Figure 4.39 O LD4NX VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 219...
  • Page 220: Figure 4.9

    NED2 NED1 NED0 Pin No. (S2) NED3 NED2 NED1 NED0 NRD3 NRD2 NRD1 NRD0 The ISDN 40V voltage is supplied by the AXL iPBX backplane. Caution: AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 220 01/2011 Description des sous-ensembles...
  • Page 221 Card in service OFF (orange) Card can be removed while powered up TABLEAU 4.41 PRESENTATION OF LD4NX CARD INDICATORS Note: Disable the card to hot unplug it. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 221...
  • Page 222 Pushbuttons The front panel includes: • an "RST" push-button used to reset the card • a "NMI" pushbutton used only at the factory. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 222 01/2011 Description des sous-ensembles...
  • Page 223: Hardware Configuration

    - A jumper placed on SW6 is used to select the 40 V power supply (on AXL only). Note: The LD4NX card has no microswitch for downloading the flash memory with a BOF3 type tool (automatic detection). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 224: Installation And Wiring

    The LD4NX card can be hot-plugged in/removed from an AXL iPBX, AXS iPBX or AXS12 iPBX in normal operation. This card must be connected with cable No. HG4731. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 224 01/2011 Description des sous-ensembles...
  • Page 225: Figure 4.40 Wiring The T0 Interface Of An Ld4Nx Card

    One end of the connection cable must be fitted with an ISO 8877 compliant male RJ45 connector. Câble point à point standard Figure 4.40 W LD4NX IRING THE T INTERFACE OF AN CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 225...
  • Page 226: Figure 4.41 Wiring An S0 Bus

    (BRI) terminal. Long bus (point to point) connecteur 1 PABX connecteur comportant les résistances d'adaptation du bus (100 Ohms, 1/4W) jusqu'à 800 m Figure 4.41 WIRING AN AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 226 01/2011 Description des sous-ensembles...
  • Page 227: Figure 4.42 Connecting A Dect Base Station To An Ld4Nx Card

    Pin 3 (RD) Pin 3 Pin 5 (NED) Pin 5 Pin 4 (ED) Pin 4 TABLEAU 4.43 TABLEAU 4.44 S0 INTERFACE LINK WITH DECT BASE STATION Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 227...
  • Page 228: Lt2 Card

    • Power supply: the LT2 card also receives on the backplane connector (J1) the +5 V supply voltage, used for the operation of its internal circuits. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 228 01/2011 Description des sous-ensembles...
  • Page 229: Figure 4.43 Overview Of The Lt2 Card

    LT2 CARD BIER BLER CRCE Console E1/T1 LT2 X LT2 CARD FRONT PANEL Figure 4.43 O VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 229...
  • Page 230: Physical Description (See Figure 4.37 )

    Pins 3 and 6: NTPIN, TPIN Pins 7 and 8: NTPOUT, TPOUT console RJ45 connector: reserved for the manufacturer. TABLEAU 4.45 DESCRIPTION OF LT2 CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 230 01/2011 Description des sous-ensembles...
  • Page 231 CRCE (red) Frame errors detected for over 50 ms BIER (red) Wrong E bit detected for over 50 ms TABLEAU 4.46 PRESENTATION OF LT2 CARD INDICATORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 231...
  • Page 232: Hardware Configuration

    (export) Extended PCM (ESF) 0 dB PCM T1 at 1.544 Mbps (export) Represents the microswitch. TABLEAU 4.47 CONFIGURATION OF MICROSWITCH CA8 ON THE LT2 CARD (1/2) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 232 01/2011 Description des sous-ensembles...
  • Page 233: Figure 3.1

    T2.E1 ISDN T2/S2 2 Mbps 16TS not used * The use of T2 or S2 is validated from Aastra Management Portal. Represents the microswitch. TABLEAU 4.47 Configuration of microswitch CA8 on the LT2 card (2/2) Installation and Maintenance Manual - Aastra 5000...
  • Page 234 Synchronisation with the PCM clock possible Synchronisation with the PCM clock not possible Represents the microswitch. TABLEAU 4.48 CONFIGURATION OF THE CA5 MICROSWITCH ON THE LT2 CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 234 01/2011 Description des sous-ensembles...
  • Page 235: Figure 3.3

    Line length = 175-210 m (574-21,000.72 cm) Line length = -18 db Represents the microswitch. TABLEAU 4.49 CONFIGURATION OF THE CA7 MICROSWITCH ON THE LT2 CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 235...
  • Page 236: Figure 3.2

    Clock signal not used Normal mode - Clock signal used (factory setting) Programming mode Represents the microswitch. TABLEAU 4.51 CONFIGURATION OF THE CA4 MICROSWITCH ON THE LT2 CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 236 01/2011 Description des sous-ensembles...
  • Page 237: Installation And Wiring

    The LT2 card cannot be hot-plugged in a working iPBX. The iPBX must be powered off before inserting the card. This card must be connected with cable No. HG4731. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 238: Pt2 Card

    • Power supply: the PLT2 card also receives on the backplane connector (J1) the +5 V supply voltage, used for the operation of its internal circuits. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 238 01/2011 Description des sous-ensembles...
  • Page 239: Figure 4.44 Overview Of The Pt2 Card

    PROG FLASH PT2 CARD PT2 CARD FRONT PANEL Figure 4.44 O VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 239...
  • Page 240: Physical Description (See Figure 4.44 )

    J6 and J7 2 x 40 pin and 2 x 20 pin connectors: location of the VOIP4E daughter card. TABLEAU 4.52 DESCRIPTION OF PT2 CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 240 01/2011 Description des sous-ensembles...
  • Page 241: Hardware Configuration

    (programming the flash memory using the CA1 on ON programming tool card) Factory delivery configuration in bold characters TABLEAU 4.54 HARDWARE CONFIGURATION OF THE PT2 CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 241...
  • Page 242: Figure 4.45 Wiring A Pt2 Card

    4.13.5.5 Installation and wiring Specific programming with Aastra Management Portal is required to declare Caution: and activate this card before it can be used. The PT2 card cannot be hot-plugged in a working system. The system must be powered off before it is plugged.
  • Page 243: Figure 4.46 How To Use A Cs1 Or Ca1 Card Built Into An Ipbx

    ETTD DTE-C system synchronous serial link type: "TRANSPAC" asynchronous serial link type: "PAD" Figure 4.46 H OW TO USE A CARD BUILT INTO AN I Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 243...
  • Page 244: Figure 4.47 Overview Of The Cs1 Card

    3 2 1 3 2 1 CS1 CARD SYNCHRONOUS PORT 1 SYNCHRONOUS PORT 0 CS1 X CS1 CARD FRONT PANEL Figure 4.47 O VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 244 01/2011 Description des sous-ensembles...
  • Page 245: Physical Description

    Clock signal sent Clock received for received data Flow control output Clock received for received data TABLEAU 4.56 CONTACTS OF THE SYNCHRONOUS CONNECTORS ON THE CS1 CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 245...
  • Page 246: Hardware Configuration

    MICRO- V10 MODE V28 MODE SWITCHES 3 2 1 3 2 1 3 2 1 3 2 1 TABLEAU 4.58 HARDWARE CONFIGURATION OF THE CS1 CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 246 01/2011 Description des sous-ensembles...
  • Page 247: Installation And Wiring

    <--- terminal present input 0 V for junction input (with V10) ---> clock received data transmitted TABLEAU 4.59 CONNECTING A DCE (CS1) TO A DTE Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 247...
  • Page 248 ---> 0 V for junction input (with V10) <---- clock received for data transmitted TABLEAU 4.60 CONNECTING A DTE (CS1) TO A DCE AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 248 01/2011 Description des sous-ensembles...
  • Page 249: Figure 4.48 Overview Of The Ca1 Card

    3 2 1 3 2 1 3 2 1 3 2 1 CA1 CARD CA1 X CA1 CARD FRONT PANEL Figure 4.48 O VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 249...
  • Page 250: Physical Description (See Figure 4.48 )

    CTS2 CTS1 CTS0 Flow control input RTS3 RTS2 RTS1 RTS0 Flow control output Data terminal input TABLEAU 4.62 DESCRIPTION OF CA1 CARD CONNECTORS TE0 - TE3 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 250 01/2011 Description des sous-ensembles...
  • Page 251 Indicators The indicators are located on the card circuit and not on the front panel. NAME STATE EXPLANATION CR1 (red) On steady Incorrect operation CR2 (red) Flashing rapidly Card in service TABLEAU 4.63 PRESENTATION OF THE CA1 CARD INDICATORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 251...
  • Page 252: Hardware Configuration

    Circuit 107 “Data set ready” (PDP or DSR) is not present on the CA1 card. The straps are not shown in this table. TABLEAU 4.65 CONNECTING A DCE (CA1) TO A DTE (PC OR VT100 CONSOLE) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 252 01/2011 Description des sous-ensembles...
  • Page 253 Circuit 107 “Data set ready” (PDP or DSR) is not present on the CA1 card. The straps are not shown in this table. TABLEAU 4.66 CONNECTING A DTE (CA1) TO A DCE (MODEM OR V24 ADAPTER) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles...
  • Page 254: Figure 4.49 Overview Of The Cp1 Card

    B channel of a Numéris link 1 2 3 CP1 CARD CP1 X CP1 CARD FRONT PANEL Figure 4.49 O VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 254 01/2011 Description des sous-ensembles...
  • Page 255: Physical Description (See Figure 4.49 )

    Jumper SW1 must be configured as shown on the diagram, with slots 1 and 2 connected together. 4.13.7.4 Installation and wiring This card has no external connections. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 255...
  • Page 256: Mum Card

    • as a single multiplexer (7 channels to 1) to a remote site on the ISDN public network, • as a double multiplexer (3 channels to 1) to two remote sites on the ISDN public network. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 256 01/2011 Description des sous-ensembles...
  • Page 257: Figure 4.50 Overview Of The Mum Card

    MUM CARD SYNC SERIAL WAN INTERFACE MUM X MUM CARD FRONT PANEL Figure 4.50 O VERVIEW OF THE MUM CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 257...
  • Page 258: Physical Description (See Figure 4.50 )

    Pin 11: Rb (RD -) • Pin 12: Lb • Pin 13: Sb (CLK-) • Pin 14: NC • Pin 15: NC TABLEAU 4.68 DESCRIPTION OF MUM CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 258 01/2011 Description des sous-ensembles...
  • Page 259: Hardware Configuration

    4.13.8.5 Installation and wiring The installation details for the MUM card are described in Document [7] (see section 1.3). The cable reference for the MUM card is HG4601A. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011...
  • Page 260 - +5 V, -5 V used for the operation of its internal circuits, -48 V used to supply the analogue set lines, - 70 V AC of the ringing current for each of the analogue sets connected. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 260 01/2011 Description des sous-ensembles...
  • Page 261: Figure 4.51 Overview Of The La16X Card

    LA16X CARD Figure 4.51 O LA16X VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 261...
  • Page 262: Physical Description (See Figure 4.51 )

    4.14.1.4 Hardware configuration This card has no configuration microswitch. 4.14.1.5 Installation and wiring The LA16X card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normal operation. The requirements for connecting an analogue terminal are: • the voltage and current measured across the station during conversation must be: U >...
  • Page 263: Figure 4.52 Wiring An Lax Or Lmx Card

    2.5 mA maximum without interference. The wiring constraints are: • maximum line length: - 0.4 mm wire: about 2 km, - 0.6 mm wire: about 3.5 km. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 263...
  • Page 264: Figure 4.53 Overview Of The La16X-8 Card

    The LA16X-8 card is functionally identical to the LA16X card (see Section4.14.1.2) except that it provides an interface with only 8 analogue sets. LA16X-8 CARD Figure 4.53 O LA16X-8 VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 264 01/2011 Description des sous-ensembles...
  • Page 265: Physical Description (See Figure 4.53 )

    This card has no configuration microswitch. 4.14.3.2 Installation and wiring The LA16X-8 card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normal operation. The other constraints relating to installing and wiring the LA16X card are identical to those for the LA16X-8 card (see Section 4.14.1.5).
  • Page 266: Figure 4.54 Overview Of The La8 Card

    LA8 card when started, but pre-programmed in the card at the factory. LA8 CARD LA8 X LA8 CARD FRONT PANEL Figure 4.54 O VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 266 01/2011 Description des sous-ensembles...
  • Page 267: Physical Description (See Figure 4.54 )

    4.14.4.5 Installation and wiring The LA8 card cannot be hot-plugged in a working iPBX. The iPBX must be powered off before inserting the card. An LA8 card cannot be plugged into AXD and AXL expansion cabinets either. The other constraints relating to installing and wiring the LA8 card are identical to those for the LA16X card (see Section 4.14.1.5).
  • Page 268: Figure 4.55 Overview Of The Ln16X Card

    - +5 V, -5 V used for the operation of its internal circuits, -48 V used to supply the digital set lines. LN16X CARD Figure 4.55 O LN16X VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 268 01/2011 Description des sous-ensembles...
  • Page 269: Physical Description (See Figure 4.55 )

    The LN16X card has no configuration microswitch. 4.14.5.5 Installation and wiring The LN16X card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normal operation. It is essential to respect the standards between weak and strong currents.
  • Page 270 The cards must be connected with cables with the following references: HG4765B, HG4765C or HG4731. The minimum diameter of the cables has to be 26AWG (0.4mm). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 270 01/2011 Description des sous-ensembles...
  • Page 271: Figure 4.56 Overview Of The Ln16X-8 Card

    The LN16X-8 card is functionally identical to the LN16X card (see Section4.14.5.2) except that it provides an interface with only 8 digital sets. LN16X-8 CARD Figure 4.56 O LN16X-8 VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 271...
  • Page 272: Physical Description (See Figure 4.56 )

    The LN16X-8 card has no configuration microswitch. 4.14.7.2 Installation and wiring The LN16X-8 card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normal operation. It is essential to respect the standards between weak and strong currents.
  • Page 273 • 0.6 mm wire: about 1800 m. The cards must be connected with cables with the following references: HG4765B, HG4765C or HG4731. The minimum diameter of the cables has to be 26AWG (0.4mm). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011...
  • Page 274: Ln8 Card

    • Pins 1, 2, 3, 6, 7, and 8: NC TABLEAU 4.75 DESCRIPTION OF THE LN8 CARD CONNECTORS Indicators This card has no signalling indicator. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 274 01/2011 Description des sous-ensembles...
  • Page 275: Figure 4.57 Overview Of The Ln8 Card

    4.14.8.5 Installation and wiring The LN8 card cannot be hot-plugged in a working iPBX. The iPBX must be powered off before inserting the card. An LN8 card cannot be plugged into AXD and AXL expansion cabinets either. The other constraints relating to installing and wiring the LN8 card are identical to those for the LN16X card (see Section 4.14.5.5).
  • Page 276: Figure 4.58 Overview Of The Lm8 Card

    The LM8 card performs the functions of both the LA8 card (see Section4.14.4.2) and those of the LN8 card (see Section4.14.8.2). LM8 CARD LM8 X LM8 CARD FRONT PANEL Figure 4.58 O VERVIEW OF THE CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 276 01/2011 Description des sous-ensembles...
  • Page 277: Physical Description (See Figure 4.58 )

    The LM8 card has no configuration microswitch. 4.14.9.5 Installation and wiring The LM8 card cannot be hot-plugged in a working AXD and AXL iPBX. The iPBX must be powered off before inserting the card. An LM8 card cannot be plugged into AXD and AXL expansion cabinets either.
  • Page 278: Lh8 Card

    4.14.10.4Installation and wiring The LH8 card cannot be hot-plugged in an operational iPBX. The iPBX must be powered off before inserting the card. An LH8 card cannot be plugged into AXD and AXL expansion cabinets either. The LH8 card has the same installation and wiring details as those of the LA8 card (see Section4.14.4.5).
  • Page 279: Figure 4.59 Overview Of The Lh8 Card

    LH8 CARD LH8 X LH8 CARD FRONT PANEL Figure 4.59 O VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 279...
  • Page 280: Figure 4.60 Overview Of The Lh16X Card

    4.14.11 LH16X card 4.14.11.1 Description The LH16X card is used to connect 16 analogue hotel terminals to An Aastra XL/XS iPBX. The LH16X card offers the same features as the LA16X card, plus an extra feature that lights up an LED on sets if messages have been left (for hotel configuration).
  • Page 281: Hardware Configuration

    This card has no configuration microswitch. 4.14.11.5 Installation and wiring The LH16X card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normal operation. The LH16X card has the same installation and wiring details as those of the LA16X card (see Section4.14.1.5).
  • Page 282: Figure 4.61 Overview Of The Lh16X-8 Card

    4.14.12 LH16X-8 card 4.14.12.1Description The LH16X-8 card is used to connect 8 analogue hotel terminals to An Aastra XL/XS iPBX. The LH16X-8 card offers the same features as the LA16X-8 card, plus an extra feature that lights up an LED on sets if messages have been left (for hotel/motel configuration).
  • Page 283: Hardware Configuration

    This card has no configuration microswitch. 4.14.12.5Installation and wiring The LH16X-8 card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normal operation. The LH16X-8 card has the same installation and wiring details as those of the LA16X card (see Section4.14.1.5).
  • Page 284: Lr4 Card

    - +5 V, -5 V used for the operation of its internal circuits, - -48 V used to supply the short analogue lines connected to PSTN equipment requiring remote supply, AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 284 01/2011 Description des sous-ensembles...
  • Page 285: Figure 4.62 Overview Of The Lr4 Card

    S1.1 D1.1 S1.2 D1.2 D1.3 D1.4 S1.3 S1.4 LR4 CARD LR4 X LR4 CARD FRONT PANEL Figure 4.62 O VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 285...
  • Page 286: Physical Description (See Figure 4.62 )

    Line used • Pulse dialling rate Flashing x: INDICATOR number, each INDICATOR is assigned to a network line TABLEAU 4.80 PRESENTATION OF THE LR4 CARD INDICATORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 286 01/2011 Description des sous-ensembles...
  • Page 287: Hardware Configuration

    FTXC daughter cards. S2.1 S2.2 SWITCH CHARGING FREQUENCY 12 kHz 16 kHz Represents the microswitch. TABLEAU 4.82 CONFIGURATION OF THE S2 MICROSWITCH ON THE LR4 CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 287...
  • Page 288: Installation And Wiring

    The LR4 card must be configured according to the length of the wiring (see Tableau 4.81 ). These cards must be connected with cable No. HG4731. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 288 01/2011 Description des sous-ensembles...
  • Page 289: Li1 Card

    The LI1 card mainly carries out the following functions: • Integration of TL command signals from the UCV card: - line seizure - release - pulse dialling Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 289...
  • Page 290 The PCM TSs exchanged with the UCV card are the medium for voice carried over a tie line. • in analogue form, from the analogue sets to the UCV card. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 290 01/2011 Description des sous-ensembles...
  • Page 291: Figure 4.63 Overview Of The Li1 Card

    -48 V used for the operation of its internal circuits. LI1 CARD R/T0 R/T1 BUSY BUSY LI1 X LI1 CARD FRONT PANEL Figure 4.63 O VERVIEW OF THE CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 291...
  • Page 292: Physical Description (See Figure 4.63 )

    TL 1 • Pin 4: R10 • Pin 5: TB10 • Pin 6: TA10 • Pin 7: GNDL TABLEAU 4.83 DESCRIPTION OF LI1 CARD CONNECTORS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 292 01/2011 Description des sous-ensembles...
  • Page 293: Hardware Configuration

    • CA1 microswitch associated with the link assigned to L1/RT1 connectors • CA2 microswitch associated with the link assigned to L0/RT0 connectors TABLEAU 4.85 CONFIGURING THE LI1 CARD Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011...
  • Page 294: Figure 4.64 Li1 Cable

    4.14.14.6Installing and wiring an LI1 card A connector lead with the reference HG4661 simplifies wiring analogue TLs on the LI1 card. R/T1 R/T0 Figure 4.64 CABLE AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 294 01/2011 Description des sous-ensembles...
  • Page 295 LERA1 white brown white "Signalling" L1 (RJ45)/ Equipment 1 blue white orange white TB10 green TA10 white GNDL brown TABLEAU 4.86 WIRING THE LI1 CABLE Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 295...
  • Page 296: Figure 4.65 Wiring A 50 Hz 2-Wire Analogue Tl

    R 10 TB 00 TB 10 TA 00 TA 10 GNDL GNDL iPBX B iPBX A Represents the microswitch. Figure 4.66 W +E&M IRING A WIRE ANALOGUE AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 296 01/2011 Description des sous-ensembles...
  • Page 297: Figure 4.67 Wiring A 4-Wire+E&M Analogue Tl

    R 10 TB 00 TB 10 TA 00 TA 10 GNDL GNDL iPBX B iPBX A Represents the microswitch. Figure 4.68 W +E&M IRING A WIRE ANALOGUE Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 297...
  • Page 298: Figure 4.69 Overview Of The Btx Card

    4.14.15.2Functional description The BTX card is used to record, store, sort, and edit on request, from a set with interactive keys, by issuing Room status tickets. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 298 01/2011 Description des sous-ensembles...
  • Page 299: Physical Description (See Figure 4.50 )

    Pin 1: Line B • Pin 2: Line B relay contact • Pin 3: not used • Pin 4: not used TABLEAU 4.87 DESCRIPTION OF THE BTX CARD CONNECTORS Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Description des sous-ensembles 01/2011 Page 299...
  • Page 300 Set EXT side: indicates buffer power supplied by connector J8 (external supply) • If set, indicates memory power supplied by the buffer battery TABLEAU 4.89 PRESENTATION OF THE BTX CARD JUMPERS AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 300 01/2011 Description des sous-ensembles...
  • Page 301: Presentation Of Peripheral Devices

    Presentation of peripheral devices Digital sets 5.1.1 Overview Aastra XS/XL/XD iPBXs allow the connection of digital sets. Only Aastra digital sets are accepted by the iPBXs. Digital sets can manage notably: • An alphanumeric screen • Programmable keys • An internal directory •...
  • Page 302: Analogue Sets

    Analogue sets 5.2.1 Description Aastra XS/XL/XD iPBXs accept the connection of analogue sets of all types and makes. Analogue sets are connected to the iPBXs through the following equipment cards: For the AXS iPBX • EXT1-S: 8 analogue sets can be connected.
  • Page 303: Description

    IP sets 5.3.1 Description Aastra XS/XL/XD iPBXs allow the transmission of voice signals with an IP set. IP sets have the same features as traditional digital sets (see Section 5.1.1). In addition, upgrade to IP brings numerous advantages: • A single network socket is enough for both the PC and telephone.
  • Page 304: Computer Terminals

    The various characteristics (connections, wiring, etc.) relating to the installation of computer terminals are described in the Sections dealing with the CS1 and CA1 cards (see Sections4.13.6 and 4.13.6.6). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 304 01/2011 Presentation of peripheral devices...
  • Page 305: Attendant Consoles (Atdc)

    • Class B: Monitoring the management of an ongoing call. An attendant console can be either a digital set with programmable keys (for example, an M760) or an attendant console on PC (for example, an Aastra i2070 Software Attendant Console).
  • Page 306: Figure 5.1 External Music / Ucv Wiring

    Once connected to the UCV or IUCV-D card, the external music source must be selected as music on-hold from Aastra Management Portal (see Document [1]). The volume of the music source can also be adjusted from Aastra Management Portal. Ω...
  • Page 307: Figure 5.2 Connecting A Common Bell (Iucv-D Card)

    The iPBX’s CPU card (UCV and IUCV-D) includes a relay used to connect an alarm bell. This relay is triggered by a problem detected on the synchronisation clock selected by the system. Alarms are assigned by MMC (AXD) Installation and Maintenance Manual - Aastra 5000...
  • Page 308: Figure 5.4

    Secteur 230V Interface sonnerie SLAT Sonnerie alternative type 1000 Ω 1 interface SLAT type TAT 524 Figure 5.5 C (UCV ONNECTING AN ALARM BELL CARD AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 308 01/2011 Presentation of peripheral devices...
  • Page 309: Installation And Activation

    PSTN and the distribution frame. Operations concerning a new installation There are several types of operations on a new installation site: Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 310: Preliminary Operations

    Follow the supplier's instructions concerning the location of the battery. • Minimum clearance A minimum clearance is required for air circulation: - 55 mm on the left side and at the back for AXD, AXL, AXS, AXS12 and AXS6 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000...
  • Page 311: Environment

    When installing inside a rack, the rack must be large enough to install the external backup battery. For future expansion of the iPBX, it is advisable to reserve some space in the rack for a second cabinet. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 312: Earth Connection

    Equipment for the new system is delivered in individual boxes. To complete a checklist of the delivered equipment, look for the package labelling and enter this information. An example of the labelling on the packages is given below: AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 312 01/2011 Installation and activation...
  • Page 313 HJ3970BA01D980353483 QTY : 1 HJ3970B Caption: 1- Product description 2- Product sales code Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 313...
  • Page 314: Installing An Axd Cabinet

    6.2.2 Installing an AXD cabinet The various installation options of an AXD cabinet are given in the following table: CABINET STACKED INSIDE A CABINET ON A WALL With mounting kit: 1 flush position TABLEAU 6.1 OPTIONS FOR INSTALLING AN AXD CABINET The cabinets in an A2XD or A3XD version can be placed on a piece of furniture, on top of one another.
  • Page 315 • Lift the cabinet and align the bracket attachment holes with those of the rack. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 315...
  • Page 316 Table 1: OPERATION DETAILS OF THE OPERATION / COMMENTS • Fix the securing brackets on the rack using screws. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 316 01/2011 Installation and activation...
  • Page 317: Installing A Cabinet (Axl, Axs, Axs12 And Axs6)

    6.2.3 Installing a cabinet (AXL, AXS, AXS12 and AXS6) The various installation options of an Aastra XS/XL cabinet are given in the following table: CABINET STACKED INSIDE A CABINET ON A WALL AXS/AXS12/ With 2-position mounting kit: AXS6 (1) (2) •...
  • Page 318 Fix the cabinet on the securing brackets using the screws in the mounting kit (2 per bracket). Caution: The front panel of the cabinet can face upwards or downwards, though we recommend turning it upwards. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 318 01/2011 Installation and activation...
  • Page 319: Wiring (Axd, Axl, Axs, Axs12 And Axs6)

    6.2.4 Wiring (AXD, AXL, AXS, AXS12 and AXS6) PRÉSENTATION On this cabinet, all connections are made on the front panel of the various sub- assemblies of the cabinet. CONTRAINTE • Always use the recommended cable (see section “Installation and wiring specifications”...
  • Page 320: Powering On The System

    • Air flows freely all around the cabinet(s) and there are no objects lying on the cabinet. There must be sufficient space between the cabinet and the wall. • All expansion cards are connected (AXD, AXL, AXS, AXS12 and AXS6 cabinets). • All equipment is connected to the cabinet and grounded.
  • Page 321 DO YOU WANT TO CHANGE CONFIGURATION Y(ES)/N(O) ? • Press " " then "Return" to confirm and return to the different fields. • Enter successively the system parameters, using the Return key to change line. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 322 Attention :This feature may result in IP address clashes. It is advisable to check that the EIP card IP address is correct for your address plan. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 322 01/2011 Installation and activation...
  • Page 323 | FTP : | TMA : | DHCP : *-------------------------------------------------* Enter: 1 for DHCP Do you confirm (Y/N)? The values entered must be 0 (deactivated) or 1 (activated). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 323...
  • Page 324 This field allows the use (1 = yes) or non-use (0= no) of the FTP service integrated into Aastra X series terminals during a first installation. The FTP server must be enabled (1) in order to then use the integrated DHCP and TMA services.
  • Page 325 SUBNET MASK: subnet mask dedicated to IP and SIP terminals BEGIN RANGE and END RANGE: Address range dedicated to IP and SIP terminals GATEWAY: gateway IP address of the network dedicated to IP and SIP terminals. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 326 [15]. Note : You can modify the factory settings completely, using the T mode after pressing Ctrl + I (see Section 6.2.7). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 326 01/2011 Installation and activation...
  • Page 327: Accessing Aastra Management Portal (User Interface)

    6.2.6.1 Accessing the user interface (Aastra Management Portal) via the LAN The operating console must be connected to the same network as the Aastra series system (CPU card LAN port). • Open a web browser installed on the operating console (Internet Explorer, for instance).
  • Page 328: Amt/Ptd/Pbx/0058/4/6/En Installation And Maintenance Manual - Aastra

    The AMP welcome screen is displayed. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 328 01/2011 Installation and activation...
  • Page 329: The Com Port (Ppp Protocol)

    6.2.6.2 Accessing the user interface (Aastra Management Portal) in local access mode via the COM port (PPP protocol) The PPP exchange protocol can set up a network type connection between two systems on a serial point-to-point link. 6.2.6.2.1 Connectors Access is provided on the COM port of the CPU card (ISDN type access), using a NULL MODEM cable (ref.: :...
  • Page 330 • After automatic detection, select " Yes, I have already connected the hardware " then choose" Add a new device " in the window that opens. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 330 01/2011 Installation and activation...
  • Page 331 • Click “Next”. • Tick the option " install the hardware I manually select from a list " then choose " Modem ". • Click "Next" Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 331...
  • Page 332 • Select the modem " Communication cable between two computers " then choose a communication port. • Click "Next" The next screen indicates that the modem is now installed: it is visible in the Device manager. • Click "Finish" AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 332 01/2011 Installation and activation...
  • Page 333 Configuring the PPP connection In Control Panel • Click " Network connections ". • Select "Create a new connection". • Tick successively the boxes indicated below. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 333...
  • Page 334 • Select the device "Communication cable between two computers". • In the next screen, indicate the restriction on the use of this connection. The connection is now defined. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 334 01/2011 Installation and activation...
  • Page 335 If the PC is located on the same network as the PBX, it is necessary to disconnect the PC from the network to force routing via PPP connection. In this case, it is more practical to use the IP address " 192.168.0.101 " of the PPP interface. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 336 • Some security windows for this "https" access mode are then displayed successively; enter “YES” for each of them. • A Login window opens, allowing access to AMP. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 336 01/2011 Installation and activation...
  • Page 337: Backup Remote Access To Amp In Ssh Mode

    Using an appropriate communication software application (putty, for example) proceed as follows: • Run this application. • Enter the IP address of the target Aastra X series system in the " Host Name" field. • Enter the port number for this connection "2222" in the "Port" field. • Click "Open".
  • Page 338 • Default access login: " admin " • Default access password: " admin " Access to the AMP interface is provided in VT100 mode. See Aastra Management Portal Operating Manual (Document [1]) for the analogy with the use of AMP in web mode.
  • Page 339: Modifying The Factory Settings

    If it becomes necessary to configure administration and telephony flow seperation, the address indicated on this screen will be dedicated to the telephony network in association with the one defined for network administration in the ADMINISTRATION NETWORK menu. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 340 | ENTER NETWORK MASK: 255.255.255.192 | | ENTER GATEWAY: 100.100.40.129 | *-------------------------------------------------* After the last line is validated, a summary of the network parameters is displayed for confirmation. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 340 01/2011 Installation and activation...
  • Page 341 EIP cards) Attention :This feature may result in IP address clashes. It is advisable to check that the EIP card IP address is correct for your address plan. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 342 • Press "Return" to confirm, after entering " " or " ". The status of FTP, TMA and DHCP services can be modified on the following screens. Refer to Section 6.2. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 342 01/2011 Installation and activation...
  • Page 343 • Press "Return" to confirm, after entering " " or " ". If the answer is " ", fill in successively the different fields, by pressing Return to change line. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 343...
  • Page 344 AASTRA 5000 CONFIGURATION / *-------------------------------------------------* | NUMBERING LENGTH: 4 | *-------------------------------------------------* DO YOU WANT TO CHANGE CONFIGURATION Y(ES)/N(O) ? • Press "Return" to confirm, after entering " ". AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 344 01/2011 Installation and activation...
  • Page 345 The fields common subscriber, common bell, IVB, modem, and hscx are read in this order and taken into account if they are in the complete block and if this number does not Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN...
  • Page 346 • After the last line is validated, a summary of the network parameters is displayed for confirmation. • The screen then displays a summary of the configuration made. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 346 01/2011 Installation and activation...
  • Page 347 Remarque :You can configure automatic or manual start of the SIP gateway or SNMP agent from the AMP. By default, the SIP gateway is started, and the SNMP agent activated. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 348: Resetting The Manufacturer's Password (In Case Of Loss)

    Contact AASTRA's customer service to obtain the values Enter Identifier and Enter Key which will be required during the procedure described below. You also need to provide the (i-Button) ID number. This number will be provided to AASTRA in order to generate the values Enter Identifier and Enter Key .
  • Page 349 The manufacturer's default access code is also reset in the menu TELEPHONY/SYSTEM/ Configuration/Users/System accounts . The AMP access login/password are reset: • Default access login: admin • Default access password: admin Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 349...
  • Page 350: Massive Import From The Massive Creation Form

    To avoid repetitive tasks on AMP, massive import consists in first creating in an Excel form a set of configuration data listed for the site. This form is then converted to a format (.csv) compatible with the Aastra X series. The file thus generated can be imported from AMP, Menu System/Software maintenance/Massive import.
  • Page 351: Operations On A Site Already Installed

    • Adding a daughter card to an expansion card or CPU card (EIP) • Adding an expansion cabinet • Adding a power module • Changing to DUPLEX configuration for AXD Software operations: • Updating the iPBX software • Backing up the configuration •...
  • Page 352: Handling Cards

    • LA16X, LA16X-8, LN16X, LN16X-8, LH16X, LH16X-8, LD4N, LD4X (AXD, AXL, AXS, AXS12 and AXS6 cabinets). All the other cards must be powered off before being removed from or inserted in an AXD, AXL, AXS, AXS12 or AXS6 cabinet. For this, it is necessary to power off the iPBX (see Section 6.4).
  • Page 353: Adding A Clx Card (Axd, Axl, Axs, Axs12 And Axs6)

    • If required, install the daughter cards on the cards requiring them. • Stop the iPBX. • (1) An LD4NX card can be hot-plugged in an AXD, AXL, AXS, AXS12 or AXS6 iPBX in normal operation. • (2) It is advisable to stop the IPS card before powering off the iPBX.
  • Page 354 • Activate the card from the operating console. • Program any additional equipment associated with the card. • Perform the card operating test. • Save the configuration. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 354 01/2011 Installation and activation...
  • Page 355: Adding An Equipment Card (Axd, Axl, Axs, Axs12 And Axs6)

    6.3.4 Adding an equipment card (AXD, AXL, AXS, AXS12 and AXS6) The iPBX can be fitted with one or more expansion cards to increase the system capacity. In an iPBX, it is possible to install all types of expansion cards according to the existing configuration and hardware configuration rules.
  • Page 356 6.3.5 Adding a daughter card on an expansion card (AXD, AXL, AXS, AXS12 and AXS6) Adding a daughter card increases the capacity of an expansion card. CONTRAINTE • The configuration data needs to be changed if the system is expanded. Before adding new components, first back up the data.
  • Page 357: Figure 6.1 Cpu Card Fitted With An Eip Card

    Adding EIP cards to an UCV CPU card The UCV cards of AXD, AXL, AXS, AXS12 and AXS6 iPBXs can be fitted with two EIP daughter cards No. 1 and EIP card No. 2 to manage VoIP calls. These two daughter cards have 8 or 32 channels each for signal processing.
  • Page 358: Figure 6.2 Cpu Card Fitted With Two Eip Cards

    CPU card may be fitted on J13 with a 32-channel EIP card and on J14 with an 8-channel EIP card. On a DUPLEX system, this combination must be identical on the passive and active cards. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 358 01/2011 Installation and activation...
  • Page 359: Adding Eip Cards For Axd Configuration

    • Re-insert the UCV card fitted with EIP cards. • Power on the system (expansion cabinets first then the main cabinet). See Aastra Management Portal operating manual for the different phases. • Declare the network parameters of the EIP cards.
  • Page 360 • Install the EIP cards on the appropriate connectors. • Re-insert the (passive) UCV-D card fitted with EIP cards. See Aastra Management Portal operating manual for the different phases. • Change the passive CPU card to “active card” mode. • Declare the network parameters of the EIP cards.
  • Page 361: Adding Eip Card(S) For Axl, Axs, Axs12 And Axs6 Configuration

    6.3.6.2 Adding EIP card(s) for AXL, AXS, AXS12 and AXS6 configuration Same procedure as in Simplex AXD configuration. See Section 6.3.6.1.1. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 361...
  • Page 362: Adding An Expansion Cabinet

    • Connect the two battery leads. • Make sure the polarity is correct. • Connect the battery to the "48V BATT." connector located at the back of the AXD cabinet. • Connect one end of the mains cable to the power supply module(s) of the expansion cabinet and the other end to a grounded mains power point.
  • Page 363: Adding An Expansion Cabinet (Axl)

    • Configure the new expansion cabinet equipment. • Configure the new expansion cabinet equipment (see AMP operating manual). • Save the configuration. 6.3.7.3 Adding an AXS, AXS12 and AXS6 expansion cabinet Procedure Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 363...
  • Page 364 • From the AMP, check that the software has detected the cabinet expansion. • Configure the new expansion cabinet equipment. • Configure the new expansion cabinet equipment (see AMP operating manual). • Save the configuration. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 364 01/2011 Installation and activation...
  • Page 365: Adding An Axd Power Module

    This procedure applies to the power modules of an AXD. An ADS350XD power supply module is added to a simplex AXD cabinet in order to secure the iPBX operation. It is installed in place of the VADS ventilation module. The cabinet thus has two power supply modules.
  • Page 366 • Secure the power supply module onto the iPBX structure using its two screws. • Connect the mains cable on the front panel of the power supply module. • Power on the power supply module. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 366 01/2011 Installation and activation...
  • Page 367: Changing To Duplex Configuration For Axd

    6.3.9 Changing to DUPLEX configuration for AXD A second UCV-D CPU card is added to a simplex AXD main cabinet (and RUCV-D for an expansion cabinet) to secure the iPBX operation. Two specific slots (see 3) are reserved for the installation of CPU cards.
  • Page 368 Note : There is a switchover when a hardware anomaly is detected on the active UCV-D card, or if the card is removed intentionally. It may also be caused by the MMC. See Aastra Management Portal operating manual. In the same menu check that the passive card has actually been taken into account by the system (status: “In service”).
  • Page 369: Stopping The System (Axd, Axl, Axs, Axs12 And Axs6)

    Stopping the system (AXD, AXL, AXS, AXS12 and AXS6) Note : Only restart modes from the CPU card front panel are described in this paragraph. Restart requests from Aastra Management Portal are not described here. See Aastra Management Portal operating manual .
  • Page 370: Viewing The Ip Address In Case Of Loss (Offline)

    • The screen then displays the cabinet’s network configuration. • Enter "N" in this screen and in the next ones if the configuration should not be modified. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 370 01/2011 Installation and activation...
  • Page 371: Updating The Software Of A Simplex Aastra System R5.1 To R5.2

    Note : See also Aastra Management Portal operating manual. 6.7.1 Principle This procedure for updating to R5.2 applies to systems running already in R5.1 (AXD, AXL, AXS, AXS12 and AXS6). To keep the IVB function, you must upgrade a 1GB CF card to 2 GB; during this upgrade to R5.2 refer to Chapter 6.12 - Upgrading from a 1 GB compact flash card to a 2 GB...
  • Page 372: Loading Update Files

    Loading update files The available modes are: • PC import • iPBX USB key 6.7.2.1.1 By PC import • Select " PC IMPORT ". • Click "Validate". AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 372 01/2011 Installation and activation...
  • Page 373 • Indicate the access path for the directory containing the file, using the "Browse" key. • If the path is known, enter it directly in the corresponding field. The file for the new version of the Aastra 5000 application is available in the A5000_Infra folder or sub-folder of the CD-ROM: - AX_R5000.2_R5.2A_A5_01.tar.gz (example)
  • Page 374 If the system does not propose it, it is not necessary to update the system version. The screen displays in this case. • Click "Validate". • The switchover window is then activated (See Section 6.7.2.3). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 374 01/2011 Installation and activation...
  • Page 375 USB key: • Create a system\ext directory under the system file root. • Create a backup\ext directory under the application file root. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 376: Switchover

    • IMMEDIATE • DEFERRED. These two modes are explained in the Aastra Management Portal operating manual. Immediate switchover Enter the new unlocking key for release R5.2. The system restarts automatically after the switchover phase.
  • Page 377 (application and/or system) and restart the upgrade afresh. This prevents, among others, any confusion with the files stored in the (temporary) memory until the switchover phase. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 378: Upgrading The Software Of A Simplex Aastra System R5.2

    The function is executed from the AMP, in the menu SYSTEM>Software maintenance>Upgrade. The upgrade concerns either the Aastra 5000 application, or the OS version, or both. The procedure is the same as the one described in Section 6.7 (except for the licences which will not be required during switchover because the system keeps the ones obtained during the first upgrade to R5.2).
  • Page 379: Restarting And Validating The New Version

    Validation and possible cancel requests are proposed in the menu "SYSTEM/Restart request" as indicated below. • To validate the release "in test", click “Validate the version”. The system restarts Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 380: Upgrading The Software From Aastra Management Am 7450

    "Confirm". The system restarts automatically with the previous release. This menu is also directly accessible via the TELEPHONY SERVICE menu, by clicking the quick link Validate the active software version. For other options, see Aastra Management Portal (Document Aastra Management Portal AXD-AXL-AXS-AXS12-A5000 Server – Operating Manual). 6.8.4 Upgrading the software from Aastra Management AM 7450 See the document Aastra Management 7450 (AM 7450) User manual.
  • Page 381: Upgrading An Axd In Duplex Configuration Mode

    To update a duplex AXD system proceed as follows: • Update the software of the active UCV-D card using the same procedure as for a simplex configuration (see Section Updating the software of a simplex Aastra system R5.1 to R5.2,...
  • Page 382: Accessing The User Interface Via An Analogue Modem

    Nota : Aastra offers at the price a 56k US Robotics analogue modem. A cable, DB25M, on the modem side - modem - DB9F on the gateway side, is used to connect the modem to the gateway.
  • Page 383 Configuring the Aastra X series system • Assign a DID number. Modem configuration • Automatic: controlled by the Aastra X Series Gateway Hayes commands for analogue US ROBOTICS modem configuration In case of ppp remote maintenance connection problem on a modem, check your modem's register configuration.
  • Page 384 Enter the address reserved for this access mode: https://192.168.0.101 (secure access mode). Some security windows for this "https" access mode are then displayed successively; enter “YES” for each of them. A login window opens. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 384 01/2011 Installation and activation...
  • Page 385: Accessing The User Interface (Amp) Via An Isdn Modem

    ACCESSING THE USER INTERFACE (AMP) VIA AN ISDN MODEM Configuring the Aastra X series system In ISDN, since the Aastra X series system is connected to the operator network, you have • Define a subscriber (by default, subscriber 796). • Assign an "HSCX modem" set type to this subscriber ("terminals allocation).
  • Page 386 - In the Security tab, retain the default value. - In the Network management tab, select and tick the values accordingly as indicated in the following screen: AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 386 01/2011 Installation and activation...
  • Page 387 • Enter the address reserved for this access mode: https://192.168.1.101 (secure access mode). Some security windows for this "https" access mode are then displayed successively; enter “YES” for each of them. A login window opens. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011 Page 387...
  • Page 388: Accessing The User Interface (Amp) Via An Isdn Router

    • Open a web browser installed on the operating console (Internet Explorer, for instance). • Enter the address reserved for this access mode: https://192.168.1.101 (secure access mode). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 388 01/2011 Installation and activation...
  • Page 389: Card

    If the space on the key is not sufficient, the following error message is displayed: " incorrect file size ". Start the data backup operation. Install the new 2 GB compact flash card on the iPBX. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 390: Migration Process

    If no key is detected, a message indicates that no key has been detected: No USB key detected On these conditions, connect a key then exit and return to the menu. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 390 01/2011 Installation and activation...
  • Page 391 • « Not enough free disk space " means that the space available on the key is not enough to contain all the data backed up. • « Impossible export " means that the data BACKUP file cannot be created. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation...
  • Page 392: Replacing The Compact Flash Card

    In case of upgrade, it will be necessary to validate this new software release. Then restore the previous configuration in the 1 GB compact flash card (see previous AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 392 01/2011 Installation and activation...
  • Page 393: Restoring Data From The Usb Key

    The restore operation lasts for about 6 minutes depending on the content to be restored and the original and target software releases. Then validate the software release. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installation and activation 01/2011...
  • Page 394 • « Software restitution failure " means that data was not correctly restored by the maintenance software. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 394 01/2011 Installation and activation...
  • Page 395: Maintenance

    The system can identify the origin of an anomaly and locate it through a message displayed in the logbook in the user interface. See Aastra Management Portal operating manual (Document [1]).
  • Page 396: Maintenance Resources

    CPU card, identifying the card resources, and identifying the hardware configuration (number of cabinets, equipment cards, presence of power supply modules and, for the AXD, presence of the IUCV-D card, presence of the passive UCV-D card, status of the active UCV-D card, etc.).
  • Page 397: Preventive Maintenance

    Error messages The CPU card centralises and broadcasts all the statuses of each of the iPBX subassemblies and peripheral lines or networks associated with Aastra Management Portal. The AMP summarises all the results and presents them in the form of error messages which appear in the operating software log.
  • Page 398: Restarting

    List of interchangeable subassemblies, fuses, batteries, cables and secu- ring kits The lists of references for the interchangeable main cards and cabinets of the Aastra XS/ XL/XD range are given in the “product bulletin”. The lists and references of the subassemblies (cards and power supply modules), cables, fuses, batteries, cabinets and mounting kits are given in Tableau 7.2 to Tableau 7.9 .
  • Page 399: Interchangeable Axd Ipbx Subassemblies

    • VOIP4E - 16 channels (PT2 daughter card) HJ4449B • VOIP4E - 32 channels (PT2 daughter card) HJ4449A • CS1 (+ cable) BHT7853A • CA1 (+ cable) BHT7852A Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 399...
  • Page 400 FTXA (LR4 daughter card, 50 Hz charge detector) HJ2817A • FTXC (LR4 daughter card, 12/16 KHz charge detector) HJ2818A • LI1 (+ cable) BHT7854A • BHJ4751A TABLEAU 7.1 LIST OF INTERCHANGEABLE AXD IPBX SUBASSEMBLIES AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 400 01/2011 Maintenance...
  • Page 401: Interchangeable Axs/Axl Ipbx Subassemblies

    CS1 (+ cable) BHT7853A • CA1 (+ cable) BHT7852A • BHJ4721A • MUM (+ cable) BHT7847A TABLEAU 7.2 LIST OF INTERCHANGEABLE AXL, AXS, AXS12, AXS6 IPBX SUB- ASSEMBLIES (1/2) Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 401...
  • Page 402: Interchangeable Axd/Axl/Axs/Axs12/Axs6 Ipbx Cables

    AXL expansion cabinet cable BHG4784A • Internal ribbon cable for AXS/AXS12/AXS6 expansion BHR0129A • FULL NULL MODEM -PPP- UCV-PC CABLE BHG0024A TABLEAU 7.4 LIST OF INTERCHANGEABLE AXD/AXL/AXS/AXS12/AXS6 IPBX CABLES AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 402 01/2011 Maintenance...
  • Page 403: Interchangeable Fuses

    TABLEAU 7.6 LIST OF LITHIUM BATTERIES 7.2.7.6 Optional interchangeable batteries INTERCHANGEABLE SUBASSEMBLY ITEM CODE • AXD and AXL cabinet battery (wall/rack) BHT7781A • AXS, AXS12, AXS6 battery cabinet (wall/rack) BHR7061A TABLEAU 7.7 LIST OF OPTIONAL INTERCHANGEABLE BATTERIES Installation and Maintenance Manual - Aastra 5000...
  • Page 404: Interchangeable Cabinets (Axd Ipbx With Ads350Xd)

    Interchangeable cabinets (AXD iPBX with ADS350XD) INTERCHANGEABLE AXD IPBX CABINET ITEM CODE • AXD main cabinet comprising: 1 UCV-D card, 1 IUCV-D card with i- BRC0036AAFR button, 1 ADS350XD power supply module • AXD main cabinet comprising: 1 UCV-D card, 1 IUCV-D card with i-...
  • Page 405: Alarm Messages And Codes

    7.3.1 Description of errors Error Description number 7.3.2 Operating system errors Value Error description (hex) 7.3.3 Programming error codes 7.3.4 Additional error codes Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 405...
  • Page 406: Corrective Maintenance

    The description of exchange operations is based on figures providing a physical description of the subassembly. If required, an additional removal/reassembly figure shows the fittings and connections of the subassembly. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 406 01/2011 Maintenance...
  • Page 407: Figure 7.1 Overview Of An Exchange Sheet (E Sheet)

    LIST OF TOOLS REQUIRED INGREDIENT CONSUMABLE LIST OF INGREDIENTS AND CONSUMABLES USED REMOVAL OPERATIONS TO PERFORM TO REPLACE THE ELEMENT REASSEMBLY Figure 7.1 O VERVIEW OF AN EXCHANGE SHEET SHEET Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 407...
  • Page 408: Conventions Used In The Sheets

    • When refitting a subassembly, check that it is inserted properly, and that the cables are connected securely. • Before performing any corrective maintenance operation on a cabinet, it is advisable to back up the client configuration (see Section 1.3, Document [4]). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 408 01/2011 Maintenance...
  • Page 409: List Of E Sheets

    Replacing an AXS12/AXS6 power supply module SHEET E-5 Replacing a VADS ventilation module SHEET E-6 Replacing fuses in the power supply module (AXD iPBX) SHEET E-7 Replacing fuses in the power supply module (AXL and AXS iPBX) SHEET E-8 Replacing a UCV-D CPU card...
  • Page 410 • Full mission capable if power supply module is duplicated OPERATORS (s) • 1 operator on site DURATION • 1 minute 30 seconds • 1 standard tool case INGRÉDIENT(S)/CONSOMMABLE(S) • N/A. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 410 01/2011 Maintenance...
  • Page 411 • Power power • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, supply module AXS12 and AXS6)Error! No bookmark name given. removed. For a duplex configuration, Avertissement :...
  • Page 412 REPLACING AN AXL POWER SUPPLY MODULE AVAILABILITY • No mission capable • 1 operator on site DURATION • 15 minutes • 1 standard tool case INGRÉDIENT(S)/CONSOMMABLE(S) • N/A. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 412 01/2011 Maintenance...
  • Page 413 In the case of remote operation, contact the remote operator before starting any operation. • Power power • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, supply module AXS12 and AXS6)Error! No bookmark name given. removed. • If it is the power supply module of a main cabinet in an iPBX with multiple cabinets, also power off the power supply module of the expansion cabinets ("I/O"...
  • Page 414 In the case of remote operation, contact the remote operator before starting any operation. • Power power • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, supply module AXS12 and AXS6)Error! No bookmark name given. removed. • If it is the power supply module of a main cabinet in an iPBX with multiple cabinets, also power off the power supply module of the expansion cabinets ("I/O"...
  • Page 415 Reinstall the expansion • Place the guide rails. cards. • Insert the card in its slot and lock it in place using the 1/4 turn locks (see Section 4.1). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 415...
  • Page 416 - then power on the power supply module in the main cabinet. • Check the status of the Refer to Section 4, Description des sous-ensemblesError! No indicators on the front bookmark name given. panel. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 416 01/2011 Maintenance...
  • Page 417 In the case of remote operation, contact the remote operator before starting any operation. • Power power • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, supply module AXS12 and AXS6)Error! No bookmark name given. removed. • Disconnect the external •...
  • Page 418 "I/O" switch on "I". supply module. • Check the status of the Refer to Section 4, Description des sous-ensemblesError! No indicators on the front bookmark name given. panel. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 418 01/2011 Maintenance...
  • Page 419 Insert the ventilation module in its slot and push it fully home. ventilation module. • Secure the ventilation module onto the iPBX structure using its two captive screws. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 419...
  • Page 420 • Power power • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, supply module. AXS12 and AXS6)Error! No bookmark name given. For a duplex configuration, Avertissement : when a power supply module is out of service, the operator has approximately 90 seconds to replace and power on again the power supply module.
  • Page 421 • Connect the mains cable • Connect the mains cable on the front panel of the power supply module. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 421...
  • Page 422 - then power on the power supply module in the main cabinet. • Check the status of the Refer to Section 4, Description des sous-ensemblesError! No indicators on the front bookmark name given. panel. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 422 01/2011 Maintenance...
  • Page 423 • Power off the cabinet's • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, power supply module. AXS12 and AXS6)Error! No bookmark name given. • If it is an iPBX with multiple cabinets, power off the power supply module of the main cabinet then those of the expansion cabinets ("I/O"...
  • Page 424 : switch and the connector. • Unclip the fuses from the fuse holder. • Check the continuity of fuses using multimeter (W position). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 424 01/2011 Maintenance...
  • Page 425 Power on the power supply module of the main cabinet (“I/O” switch on “I”). • Check the status of the Refer to Section 4, Description des sous-ensemblesError! No indicators on the front bookmark name given. panel. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 425...
  • Page 426 • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6).Error! No bookmark name given. For a system with several cabinets, first power off the main cabinet, then the expansion cabinet(s). Nota : (1) All the system’s services are interrupted when a non- duplicated UCV-D card is being replaced.
  • Page 427 Contact your distributor if the details do not coincide. • Check the status of Refer to Section 4, Description des sous-ensemblesError! No bookmark name the indicators on the given. front panel. • Back customer configuration. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 427...
  • Page 428 Nota : The UCV-D card can be removed from an operational AXD iPBX. • Check that the functional technical state of the new card is compatible with the old one. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 428 01/2011 Maintenance...
  • Page 429 Contact your distributor if the details do not coincide. • Check the UCV-D card Refer to Section 4, Description des sous-ensemblesError! No indicators. bookmark name given. • Back up the customer configuration. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 429...
  • Page 430 • Partial mission capable if the RUCV-D card is not duplicated • Full mission capable if the RUCV-D card is duplicated OPERATORS (s) • 1 operator on site DURATION • 2 minutes INGRÉDIENT(S)/CONSOMMABLE(S) • N/A AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 430 01/2011 Maintenance...
  • Page 431 (refer to Section4.5 to check that the operating conditions indicated by the LEDs are correct). • Activate the RUCV-D card Refer to the document [1]. from the AMP. • Back up the customer configuration. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 431...
  • Page 432 • Lock the card in place using the 1/4 turn locks (seeFigure 4.1 ). Nota : The RUCV-D card can be hot-plugged in an operational AXD iPBX. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 432 01/2011 Maintenance...
  • Page 433 (refer to Section4.5 to check that the operating conditions indicated by the LEDs are correct). • Back up the customer configuration. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 433...
  • Page 434 (the directory, for instance). Simple call (also for IP sets) remain operational. • Recover i-button • Recover, on the IUCV-D card, the i-button module containing the module. system's identifier. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 434 01/2011 Maintenance...
  • Page 435 (refer to Section 4.4 to check that the operating conditions indicated by the LEDs are correct). • Activate the IUCV-D card Refer to the document Aastra Management Portal AXD-AXL-AXS- from the AMP. AXS12-A5000 Server – Operating Manual. • duplex...
  • Page 436 • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6)Error! No bookmark name given. • For a system with several cabinets, first power off the main cabinet, then the expansion cabinet.
  • Page 437 “I”. - Set the “I/O” switch on the main cabinet power supply module(s) “I”. • Check the status of the indicators (see Sections 4.3 to 4.7). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 437...
  • Page 438 DETAILS OF THE OPERATION / COMMENTS • Check the UCV-D card's • Refer to the document [1]. system and application software releases using the AMP. • Restore the data of the old configuration. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 438 01/2011 Maintenance...
  • Page 439 • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6)Error! No bookmark name given. • For a system with several cabinets, first power off the main cabinet, then the expansion cabinet.
  • Page 440 “I”. • Check the status of the indicators (see Sections 4.6). • Check the UCV card's • Refer to the document Aastra Management Portal AXD-AXL- system and application AXS-AXS12-A5000 Server – Operating Manual. software releases using the AMP. •...
  • Page 441 • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6)Error! No bookmark name given. • For a system with several cabinets, first power off the main cabinet, then the expansion cabinet.
  • Page 442 - Fit the cover slightly to the rear of the cabinet and push it forward. - Tighten the two securing screws at the back of the cabinet. • Fit the new cabinet. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 442 01/2011 Maintenance...
  • Page 443 - Set the “I/O” switch on the main cabinet power supply module to position “I”. • Check the status of the indicators (see Sections 4.6). • Check the UCV card's Refer to the document Aastra Management Portal AXD-AXL-AXS- system and application AXS12-A5000 Server – Operating Manual. software releases using the AMP. •...
  • Page 444 • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6)Error! No bookmark name given. Nota : It is advisable to stop the IPS card before powering off the iPBX.
  • Page 445 • Refer to the document [1]. system and application software releases using the AMP. • Restore the data of the • Refer to the document [1]. old configuration. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011 Page 445...
  • Page 446 • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6)Error! No bookmark name given. • For a system with several cabinets, first power off the main cabinet, then the expansion cabinet(s).
  • Page 447 - power on the expansion cabinet then the main cabinet. - “I/O” switch on the power supply module(s) set to “I”. • Check the status of the indicators (see Sections 4.3 to 4.7). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011...
  • Page 448 In the case of remote operation, contact the remote operator before starting any operation. • Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and AXS6)Error! No bookmark name given. • First power off the main cabinet then the expansion cabinet. •...
  • Page 449 - “I/O” switch on the power supply module set to “I”. • Check the status of the indicators (see Sections 4.6 to check that the functional statuses provided by the indicators are correct). Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Maintenance 01/2011...
  • Page 450: Amt/Ptd/Pbx/0058/4/6/En Installation And Maintenance Manual - Aastra

    AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 450 01/2011 Maintenance...
  • Page 451: Installing And Using The Ips Card

    The installation and use of the IPS card are described in a special manual (see document [13]). From R5.1(A5000 environment), it is mandatory to desactivate the embedded Caution: GSI. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Installing and using the IPS card 01/2011 Page 451...
  • Page 452 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 452 01/2011 Installing and using the IPS card...
  • Page 453: Functional Diagrams

    • Functional diagram of an Aastra XD in simplex configuration (Plate 9.1) • Functional diagram of an Aastra XD in duplex configuration (Plate 9.2) • Functional diagram of an Aastra XL, XS, XS12 and AXS6 (Plate 9.3) • Principle of multi-site synchronisation Plate 9.4)
  • Page 454 AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 454 01/2011 Functional diagrams...
  • Page 455 Plate 9.1 FUNCTIONAL DIAGRAM OF AN AASTRA XD IN SIMPLEX CONFIGURATION...
  • Page 456 Plate 9.2 FUNCTIONAL DIAGRAM OF AN AASTRA XD IN DUPLEX CONFIGURATION tenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN...
  • Page 457 Private system stations ISDN * function is also integrated on the UCTL, UCTS and UCTS-12 boards (eg. PBX) ** function is also integrated on the UCTS and UCTS-12 boards Plate 9.3 FUNCTIONAL DIAGRAM OF AN AASTRA XL, XS AND XS12...
  • Page 458 Plate 9.4 PRINCIPLE OF MULTI-SITE SYNCHRONISATION tenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN...
  • Page 459: Installing A5000 Server (Non-Redundant)

    INSTALLING A5000 SERVER (NON-REDUNDANT) This chapter describes how to install the non-redundant A5000 Server application. For the redundant Aastra 5000 server, refer to AMT/PTD/PBX/0083. 10.1 Important pre-requisite As of R5.2, the Linux operating system, Red Hat 5.4 minimum, must first be installed on the PC.
  • Page 460 | => EXP | *-------------------------------------------------* DO YOU CONFIRM (Y/N)? Y • Validate the modifications with the "Return" key, after confirming or rejecting them by pressing "y" or "n". AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 460 01/2011 INSTALLING A5000 SERVER (Non-redundant)
  • Page 461 • To modify the system's PARI number, type in " " and enter the corresponding value. • Validate the modifications with the "Return" key, after confirming or rejecting them by Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN INSTALLING A5000 SERVER (Non-redundant)01/2011...
  • Page 462 FTP service is started by AMP. There is no automatic action on A5000 Server like on Aastra X series systems if the FTP and TMA services are started at the same time. The TFTP service is automatically configured when the TFTP service is started by AMP.
  • Page 463 The FTP service is used to download via TMA the firmware and configuration files used by Aastra terminals 53xxip and 67xxi and the terminals used by Aastra terminals 53xx. Refer to the document Installation manual Aastra 53xxip and Aastra 67xxi Aastra 53xx sets - AMT/PTD/TR/0014 .
  • Page 464 This field is used to activate the LLDP protocol in the terminal, (1 = yes) or no (0= no). VLAN ID and VLAN PORT: These parameters are used to define the VLAN dedicated to Aastra terminals A67xxi. They are not obligatory on simple networks.
  • Page 465 (A5000 Server). DID: Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN INSTALLING A5000 SERVER (Non-redundant)01/2011...
  • Page 466 DO YOU WANT TO CHANGE CONFIGURATION Y(ES)/N(O) ? • Validate the modifications with the "Return" key, after confirming or rejecting them by pressing "y" or "n". AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 466 01/2011 INSTALLING A5000 SERVER (Non-redundant)
  • Page 467 This field is used to associate a public number (format: 0130967000 or +33(0)130967000) with the DID number for block 0. This ASCII string will be truncated to 20 characters. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN INSTALLING A5000 SERVER (Non-redundant)01/2011 Page 467...
  • Page 468 | IF YOU DON'T WANT, PLEASE CONSULT THE INSTALL DOC | • Press "Return" to confirm, after entering " " or " ". • The screen then displays a summary of the configuration made (example): AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 468 01/2011 INSTALLING A5000 SERVER (Non-redundant)
  • Page 469 " if the values displayed are correct and confirm by pressing "Return". • Then restart the system (mandatory). The configuration phase is complete. Initial installation is complete and you can now configure the site (see Aastra Management Portal operating manual). Installation and Maintenance Manual - Aastra 5000...
  • Page 470: Accessing The (Amp) User Interface

    10.3 Accessing the (AMP) user interface The operating console must be connected to the same network as the Aastra series system (CPU card LAN port). • Open a web browser installed on the operating console (Internet Explorer, for instance). • Enter the IP address defined for the system: https://@IP (secure access mode) Note : Address defined while installing the Redhat OS corresponding to the IP address of the A5000 Server network card.
  • Page 471 The AMP welcome screen is displayed. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN INSTALLING A5000 SERVER (Non-redundant)01/2011 Page 471...
  • Page 472: Declaring The Licences For Virtual A5000 Server

    The installation code frame then gives the value of the installation code. • Click OK to close the window. • Log on to the licence server http://support.aastra.fr/akop/external.php and enter this installation code. This server then generates the actual licence for the functions specified during the order.
  • Page 473: Resetting The Manufacturer's Password (In Case Of Loss)

    Contact AASTRA's customer service to obtain the values Enter Identifier and Enter Key which will be required during the procedure described below. You also need to provide the (USB dongle) ID number. This number will be provided to AASTRA in order to generate the values Enter Identifier and Enter Key.
  • Page 474 TELEPHONY>SYSTEM>Configuration>Users>System accounts . The AMP access login/password are reset: • Default access login: admin • Default access password: admin AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 474 01/2011 INSTALLING A5000 SERVER (Non-redundant)
  • Page 475: Massive Import From The Massive Creation Form

    To avoid repetitive tasks on AMP, massive import consists in first creating in an Excel form a set of configuration data listed for the site. This form is then converted to a format compatible (.csv) with Aastra 5000 Server. The file thus generated can be imported from AMP, Menu System>Software maintenance>Massive import.
  • Page 476: Additional Configurations

    10.7.1 Starting and viewing the services You can configure the services (LDAP, SNMP, GSI, FTP, TFTP, etc.) and display their status from the "SYSTEM>Configuration>Services" menu of Aastra Management Portal. See Aastra Management Portal operating manual. 10.7.2 Declaring an NTP time server It may be necessary to synchronise an NTP server, especially for some terminal types.
  • Page 477: Upgrading Aastra 5000 Server Software R5.1 To R5.2

    • The new software licence associated with R5.2 must be retrieved before starting the procedure. Note : Linux Redhat 5.4 may equally be fully reinstalled without going through the upgrade phase. In this case, refer to document Red Hat OS Installation manual. Then reinstall the Aastra 5000 Server R5.2 software. 10.8.2 Upgrading Red Hat 5.4...
  • Page 478: Checking The Release Of Red Hat Enterprise

    The R5.2 licence can be declared using Ctrl + i, or later from AMP, since the R5.1 licence is not recoverable. 10.8.5 Restoring the R5.1 data Refer to Section Backing up and restoring the configuration. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 478 01/2011 INSTALLING A5000 SERVER (Non-redundant)
  • Page 479: Upgrading Aastra 5000 Server R5.2 Software

    • Upgrade for software upgrade releases • Delta for anomaly corrections. These software elements will be loaded on the Compact Flash card located on the Aastra series CPU card. The A5000 Server application software is upgraded from the AMP, menu SYSTEM>Software maintenance>Upgrade.
  • Page 480 Two media types can be used: • CDROM • USB key Insert the CD in the (AMP) client PC on which the software update commands are executed. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 480 01/2011 INSTALLING A5000 SERVER (Non-redundant)
  • Page 481: Loading The Application

    10.9.2.1 Loading the application The available modes are: • PC import • iPBX USB key 10.9.2.1.1By PC import • Select " PC IMPORT ". • Confirm. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN INSTALLING A5000 SERVER (Non-redundant)01/2011 Page 481...
  • Page 482 A5000_R5000.2_R5.2_A5_01.tar.gz CD-ROM (example). A5000 server file Aastra X series: Application file to be downloaded (see the corresponding chapter) Aastra X series: System file to be downloa- ded (see the corresponding chapter) AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 482...
  • Page 483 A message indicates the progress of the downloading phase. • Click "Validate". The switchover window is then activated (See Section 10.9.3). 10.9.2.2.2By USB key Not available with this release Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN INSTALLING A5000 SERVER (Non-redundant)01/2011 Page 483...
  • Page 484: Switchover

    System switchover in the new version loaded is proposed in two modes: • IMMEDIATE • DEFERRED. These two modes are explained in the Aastra Management Portal operating manual AXD- AXL-AXS-AXS12-A5000 Server – Operating manual The system restarts automatically after the switchover phase.
  • Page 485: Restarting And Validating The New Version

    If you do not wish to validate the release "in test" but to return to the previous release, select "Validate the version" and click "Confirm". The system restarts automatically with the previous release. For other options, see Aastra Management Portal AXD-AXL-AXS-AXS12-A5000 Server – Operating manual. Installation and Maintenance Manual - Aastra 5000...
  • Page 486: Via Aastra Management Am 7450

    See Installation manual for redundancy and double attachment on A5000 Server. 10.11 Backing up and restoring the configuration Backup and restore operations are performed from Aastra Management Portal. See Aastra Management Portal operating manual. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000...
  • Page 487: Appendices

    Therefore, you have to indicate to the web browser that the company is a reliable certification authority. For Aastra X series (AXD, AXL and AXS) iPBXs • Open a web browser installed on the operating console (Internet Explorer, for instance).
  • Page 488 • In the following screen, select the "Certification access path" tab then click the root certificate (in the example "Aastra"). • Click "Display certificate". AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 488 01/2011 Appendices...
  • Page 489 • Click "Install certificate". The installation then starts. • Click "Next" • Click "Next" Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Appendices 01/2011 Page 489...
  • Page 490 The certificate is installed. • Click “OK" The installation is complete; all the sites certified through the root name (in the example “Aastra”) will no longer display the Internet Explorer security alert. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000...
  • Page 491 Note : Default address in factory setting: 192.168.65.01 In the Certificate screen • Select Accept this certificate definitelythen click OK. In the Security warning screen • Click OK. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Appendices 01/2011 Page 491...
  • Page 492: Activating/Deactivating Selinux In Red Hat 5

    11.2 ACTIVATING/DEACTIVATING SELINUX IN RED HAT 5 From the PC on which AASTRA 5000 is installed SELinux is activated or deactivated in the "SELinux" tab of the menu "System/ Administration/Security level and firewall": AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000...
  • Page 493: Configuring The Firewall For Acs

    In this window, enter the port number and select a protocol then click Confirm. The port is added to the list. When all the ports are configured, click Apply then Confirm. The firewall is configured. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Appendices 01/2011...
  • Page 494: Amt/Ptd/Pbx/0058/4/6/En Installation And Maintenance Manual - Aastra

    The following table gives the list of ports to open for the A5000 server installation. AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000 Page 494 01/2011 Appendices...
  • Page 495 Additional items on the list of TCP ports used by the internal servers of A5000 Server Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Appendices 01/2011 Page 495...
  • Page 496: Using The Massive Creation Form

    The generated files will have to be imported one by one during the Massive import phase from the AMP menu System/Software maintenance/Massive import. The data thus generated in .csv format will be compatible with the Aastra 5000 systems during massive import. This data may later be processed as any other parameter data type, using the Export function.
  • Page 497: Structure And Content Of The Excel Form

    • The cells on the second line (line 2) indicate the invariable internal codes for these parameters. These codes are used by the Aastra 5000 system software, in the corresponding menu, to interpret the values to be taken into account during import in .csv format.
  • Page 498 Some columns and associated cells are hidden intentionally in the original form, to improve display. These fields correspond to those not modifiable from AMP menus. The characters used must be alphanumeric characters (the same syntax as for Aastra 5000 system management).
  • Page 499: Backing Up The File In .Csv Format

    0. In this case, these cells must be completed again as indicated previously. After the modifications, check systematically the value of the Confirmation cells for each line. Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN Appendices...
  • Page 500: External Record Creation Tab

    Correspondence with the filling of the fields in the menu Subscribers/ Directory/External records/Creation of an external record For correspondence with the possible options and values, as well as their syntax, see Section 4.2.2 of the Aastra Management Portal Operating Manual (Document [1]). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000...
  • Page 501: Selection Keys Tab

    Subscribers/Subscriptions/Characteristics/Keys For correspondence with the possible options and values, as well as their syntax, see Section 4.3.7of the Aastra Management Portal Operating Manual (Document [1]). Refer also to the respective terminal documentation for information on the number of programmable keys.
  • Page 502: Multi-Lines Tab

    Correspondence with the filling of the menu fields Multi-lines For correspondence with the possible options and values, as well as their syntax, see Section 4.3.11 of the Aastra Management Portal Operating Manual (Document [1]). AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000...

This manual is also suitable for:

AxlAxsAxs125000Axs6

Table of Contents