4.14.4.3 Physical description (see Figure 4.54 )
Connectors
NAME
J1
A0 to A7
8
1
Indicators
This card has no signalling indicator.
4.14.4.4 Hardware configuration
The LA8 card has no configuration microswitch.
4.14.4.5 Installation and wiring
The LA8 card cannot be hot-plugged in a working iPBX. The iPBX must be powered off
before inserting the card. An LA8 card cannot be plugged into AXD and AXL expansion
cabinets either.
The other constraints relating to installing and wiring the LA8 card are identical to those
for the LA16X card (see Section 4.14.1.5).
The minimum diameter of the cables has to be 26AWG (0.4mm).
Installation and Maintenance Manual - Aastra 5000
Description des sous-ensembles
FUNCTION/CHARACTERISTIC
96-pin connector:
backplane connection.
RJ45 connectors: each socket provides
one connection to an analogue set
TABLEAU 4.72 DESCRIPTION OF LA8 CARD CONNECTORS
•
Pin 4: analogue set (i)+
•
Pin 5: analogue set (i)-
•
Pins 1, 2, 3, 6, 7, and 8: NC
AMT/PTD/PBX/0058/4/6/EN
01/2011
CONTACTS
Page 267