SHEET E-5
REPLACING A VADS VENTILATION MODULE
AVAILABILITY
• Full mission capable
OPERATORS (s)
• 1 operator on site
DURATION
• 1 minute 30 seconds
• 1 standard tool case
INGRÉDIENT(S)/CONSOMMABLE(S)
• N/A.
See Figure 4.3 for an overview of the power supply module.
Table 8:
OPERATION
Alert the operator.
Check
the
functional
technical state of the new
VADS ventilation module.
Remove the ventilation
module.
Fit
the
new
ventilation module.
Installation and Maintenance Manual - Aastra 5000
Maintenance
DETAILS OF THE OPERATION / COMMENTS
In the case of remote operation, contact the remote operator
before starting any operation.
Check that the functional technical state of the new ventilation
module is compatible with the old one.
Avertissement :
90 seconds to make the replacement. After 90 seconds,
the power supply module is automatically powered off.
Unscrew the two securing screws on the front panel of the
ventilation module.
Remove the ventilation module using its handles.
VADS
Insert the ventilation module in its slot and push it fully home.
Secure the ventilation module onto the iPBX structure using its
two captive screws.