10.9.4
Restarting and validating the new version
After the software is upgraded, the installed version is not automatically validated during
switchover. You must validate the new version manually after noticing that it is running
satisfactorily.
You can validate it through the menu "SYSTEM > Restart request".
As long as the new version is not validated:
• it remains "in test",
• It is possible to restore the previous release.
• It is not possible to carry out a restore operation on this version.
It is advisable to validate the new version as quickly as possible (once
you observe a normal operation).
Procedure
Validation and possible cancel requests are proposed in the menu "SYSTEM>Restart
request" as indicated below.
• To validate the release "in test", click "Validate the version". The system restarts
automatically, declaring the release as valid.
If you do not wish to validate the release "in test" but to return to the previous release,
select "Validate the version" and click "Confirm". The system restarts automatically with
the previous release.
For other options, see Aastra Management Portal AXD-AXL-AXS-AXS12-A5000 Server –
Operating manual.
Installation and Maintenance Manual - Aastra 5000
INSTALLING A5000 SERVER (Non-redundant)01/2011
AMT/PTD/PBX/0058/4/6/EN
Page 485