The principle for wiring an analogue set is shown in the diagram below:
8
1
Carte LAx ou LMx
Each line is supplied with balanced direct current. This voltage may vary between -43 V
and -56 V.
The maximum line resistance for a 22mA current is 1000 Ohm. The maximum line current
for a 200 Ohm resistance is 40 mA. With the "set on hook" the permanent line current can
reach 2.5 mA maximum without interference.
The wiring constraints are:
• maximum line length:
- 0.4 mm wire: about 2 km,
- 0.6 mm wire: about 3.5 km.