Ips (2) - Aastra AXD Installation And Maintenance Manual

Aastra 5000 server installation and maintenance manual
Table of Contents

Advertisement

Understanding Tableau 3.8 :
• Synchronising position: indicates a synchronising position. The H0 clock signal in
position 1-00 has priority over H1, H2, H3, H4 and H5 which have the same priority
level.
• Yes: indicates that the card concerned can be equipped.
• No: indicates that the card concerned cannot be equipped.
• #8 to #13: indicates that the card can be equipped if no card in the short list is installed
in slot n in the main cabinet.
Exemple : If a PT2 + VOIP 16 card is installed in slot 1-00 (#8), a card from the short
Exemple : If an LD4 or LD4N card is installed in slot 1-00 (#8), a card from the short
- Short list:
PT2, LD4, LD4N for slots 00 to 05.
- Full list:
channel PT2, LT2, BTX. LD4X, 0-channel PT2 0.
Installation and Maintenance Manual - Aastra 5000
Description et caractéristiques d'un PBX
list cannot be installed in slot 1-08. If a PT2 + VOIP16 card is installed in 1-
01 (#9), a card from the short list cannot be installed in 1-09...
list cannot be installed in slot 1-08, but a card from the full list can be
installed.
LA8, LN8, LM8, LH8, LI1, LR4, CP1, 8-channel PT2, MUM
LA16X, LN16X, LA16X-8, LN16X-8, LH16X, LH16X-8, CS1, CA1,
01/2011
AMT/PTD/PBX/0058/4/6/EN
Page 89
and 16-channel
IPS, 32-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

AxlAxsAxs125000Axs6