OPERATION
RPMS, CS50 & CS70-D100U/UF User's Manual
3-38
Figure 3.22. Enabling Brightness Uniformity
– Use this option to select a variety of test patterns. Select the 13
TEST PATTERNS
Point test pattern when adjusting Brightness Uniformity.
White Uniformity is a
WHITE UNIFORMITY -
submenu accessible only when the Uniformity
Enable checkbox is checked. The options here
allow you to match light output across multiple
screens, which is extremely important in display
walls. This enhances the appearance of a
seamless image.
Each option in this menu represents an area of the
screen – edge or corner. By adjusting the slidebar
for each option you can control the light output in these areas. See Adjusting
Brightness Uniformity later in this section for complete instructions on how to adjust
White Uniformity in a display wall.
– refer to description under Image Settings.
COLOR TEMP SETUP
– When you select this option it will take you to the Lamp menu, also
LAMP
accessible from the Main menu. Refer to The Lamp Menu later in this section for
complete details.
Auto Power Up
Enter a check mark to enable the projector to automatically power up after losing
power to unplugging or a power failure. Note that unsaved display adjustments may
be lost.
Diagnostics and Calibration
From the Diagnostics and Calibration menu you can access options useful in
calibration and setup of an image. You can access test patterns, enable various colors,
freeze an image for inspection and access the Odd Pixel Adjustment menu.