Error
Error message
code
Accessed other network.
407
Change network setting.
Cannot perform operation
410
because of PLC run mode. stop
the PLC.
Memory cassette is write-
411
protected. Check the memory
cassette.
Cannot read/write device
412
protected by keyword. Remove
keyword.
420 E71 specification is ASCII.
E71 is set as read-only. Clear
421
setting.
Not communicating between
422
CPU and E71. Confirm CPU
error.
Insufficient network table
423
information. Add station no.
• When monitoring the same network as the GOT
The GOT accesses the other networks with the MELSECNET/H,
MELSECNET/10 (PLC to PLC network), or CC-Link IE Controller
Network connection. Confirm the network number of the project data
so as not to access to other networks.
• When monitoring other networks
Reconfigure the [Routing Information Setting] of GT Designer3 or GT
Designer2 or the [Routing parameters] of GX Developer.
• When using GT15-75J71LP23-Z/GT15-75J71BR13-Z
Other networks cannot be monitored.
Confirm the network number of the project data so as not to access to
other networks.
The operation, which could not be performed during RUN of PLC CPU,
was performed.
Stop the PLC CPU.
The memory cassette installed in the PLC CPU is EPROM or E
and it is in a protected status.
Confirm the memory cassette installed in PLC CPU.
The key word is set in PLC CPU.
Cancel the key word.
[ASCII code] is selected in [Ethernet operations] of the PLC side setting.
Select [Binary code].
The Ethernet module on the PLC side is set in read-only.
Set the Ethernet module on the PLC side to write-enabled.
PLC CPU error. Communication between PLC CPU and the PLC side
Ethernet module impossible.
Confirm whether there is error in PLC CPU by GX Developer etc.
(Confirm buffer memory)
The station number set in the project data and the station number set in
the switching station No. device do not exist in the Ethernet setting of GT
Designer3 or GT Designer2.
• Add the station number set in the project data to the Ethernet setting
of GT Designer3 or GT Designer2.
• When using the station No. switching function, check the data of the
switching station No. device.
When the station number specified in the switching station No. device
is not set in the Ethernet setting, add the
Ethernet setting.
When the station number does not exist in the system, change the data
of the switching station No. device.
(Set the station number so that it becomes the same as the station
number of the PLC side Ethernet module set in the parameter setting
of GX Developer.)
10.3 Error Message and System Alarm
Action
2
PROM,
station number to the
9
Channel No.
storage
10
10 - 21