Mitsubishi GT16 User Manual page 183

Hide thumbs Also See for GT16:
Table of Contents

Advertisement

Error
Error message
code
Recipe file make error. Reboot
352
GOT after inserting memory
card.
Unable to write Recipe file.
353
Confirm memory card is
inserted.
354 Recipe file write error
355 Recipe file read error
File system error occurred in
356
PLC. Confirm file register.
Error in specified PLC drive
357
Confirm PLC drive
PLC file access failure. Confirm
358
PLC drive.
Processing from another
359
peripheral device. Execute it
after.
0 divisor division error. Confirm
360
operation expression.
Specified device No. is out of
361
range.
Invalid device value in time
362
action setting
Upper and lower limit value
370
error. Confirm value setting.
Insufficient USB drive capacity.
380
Confirm the drive capacity.
Failed to generate recipe file.
Reboot the GOT after installing the CF card or USB memory.
Failed to write in the recipe file.
• Confirm the write-protection of the CF card or USB memory.
• Confirm the contents of the CF card or USB memory.
• Do not pull out the CF card or USB memory while recipe is operating.
Error occurred while writing in the recipe file.
Do not unplug the CF card or USB memory while recipe is operating.
Error occurred while writing in the recipe file.
• Do not unplug the CF card or USB memory while recipe is operating.
• Confirm the contents (device value) of the recipe file in the CF card or
USB memory.
Error occurred in the specified file register when executing the recipe
function by specifying the file register name.
• Execute the recipe function again after confirming the file register
name.
• Execute the recipe function again after formatting the PC memory in
the specified PLC CPU drive with GX Developer.
When executing the recipe function specifying the file register name,
error occurred in PLC CPU drive.
• Execute the recipe function again after confirming the specified PLC
CPU drive.
• Execute the recipe function again after formatting the PC memory in
the specified PLC CPU drive with GX Developer.
When the recipe function is executed specifying the file register name,
PLC CPU file register could not be accessed.
• Execute the recipe function again after confirming the specified PLC
CPU drive / file register name. (When you specify drive 0, execute the
recipe function again after changing to other drives.)
• Confirm whether the CF card or USB memory are write-protected, and
execute the recipe function again.
• Confirm that the security key is not set on the specified CPU, and
execute the recipe function again.
When the recipe function is executed specifying the file register name,
other peripherals carry out the process to the file register.
Wait until the processing of other peripherals end, and execute the recipe
function again.
Zero division occurred by the data operational expression.
Review the data operational expression so that the divisor should not
become 0.
The entered file number is out of range.
Check the entered file number, and enter a valid value (1 to 9999).
When controllers are controlled with the GOT's time action function, the
set No. is our of range, or the set device values regarding the operation
settings are out of range or invalid.
Set valid values.
The setting of lower/upper limit value is [Upper limit < Lower limit].
Correct the setting so as to be "Upper limit
Available memory of the USB memory is insufficient.
Confirm the available memory of the USB memory, and increase the
memory if it is low.
10.3 Error Message and System Alarm
Action
Lower limit".
9
Channel No.
storage
10
10 - 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Got 1000 gt16