Code
Contents
6050
Abnormally low fuser
thermistor 1 temperature
Fuser thermistor 1 detects a
temperature lower than
100°C/212°F for 1 s after
warming up.
6120
Abnormally high fuser
thermistor 4 temperature
Fuser thermistor 1 detects a
temperature higher than
190°C/374°F for 1 s.
6130

Broken fuser thermistor 4

wire
Input from fuser thermistor 4
is 992 or more (A/D value)
continuously for 1 s.
6150
Abnormally low fuser
thermistor 4 temperature
Fuser thermistor 4 detects a
temperature lower than 30°C/
86°F for 1 s after warming up.
Causes
Deformed connec-
See page 1-4-59.
tor pin.
Defective triac.
See page 1-4-59.
Defective fuser
Replace the fuser unit (see page 1-5-45).
thermistor 1.
Defective fuser IH.
Replace the fuser unit (see page 1-5-45).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Deformed connec-
See page 1-4-59.
tor pin.
Defective triac.
See page 1-4-59.
Shorted fuser
Replace the fuser unit (see page 1-5-45).
thermistor 4.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser unit and engine PWB (YC26)
Deformed connec-
See page 1-4-59.
tor pin.
Defective triac.
See page 1-4-59.
Broken fuser
Replace the fuser unit (see page 1-5-45).
thermistor 4 wire.
Defective fuser IH.
Replace the fuser unit (see page 1-5-45).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Deformed connec-
See page 1-4-59.
tor pin.
Defective triac.
See page 1-4-59.
Defective fuser
Replace the fuser unit (see page 1-5-45).
thermistor 1.
Defective fuser IH.
Replace the fuser unit (see page 1-5-45).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).