U161
Setting the fusing control temperature
Description
Changes the fusing control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fusing problem on thick paper.
Method
Press the enter key. A selection item appears.
Setting
1. Select the item to be set using the up/down cursor keys.
2. Change the setting using the left/right cursor keys.
Display
First Temp.
Second Temp.
Copy Temp. 1
Copy Temp. 2
Temp. 1 Cont. #
Printing operation temperature 1: Temperature in printing operation at the start of printing
Printing operation temperature 2: Temperature in printing operation after the specified number of sheets for
Number of sheets for fusing control: The number of sheets to be counted for switching from printing
The temperatures are to be set such that Secondary stabilization > = Primary stabilization.
3. Press the enter key. The value is set.
Completion
Press the back key. The indication for selecting a maintenance item No. appears.
U163
Resetting the fusing problem data
Description
Resets the detection of a service call code indicating a problem in the fusing section.
When a service call concerning the fusing section occurs, turn the power switch off and open the front cover.
Then, turn the power switch on and press the system menu/counter key to enter the maintenance mode.
Purpose
To prevent accidents due to an abnormally high fusing temperature.
Method
1. Press the enter key. A selection item appears.
2. Select Execute using the up/down cursor keys.
3. Press the enter key. The fusing problem data is initialized. (Four service calls, namely C6000, C6020,
C6050, and C6400 are reset.)
Completion
Press the back key. The indication for selecting a maintenance item No. appears.
1-4-12
Description
Description

Primary stabilization fusing temperature

Secondary stabilization fusing temperature 100 to 165 (°C)
Printing operation temperature 1
Printing operation temperature 2
Number of sheets for fusing control
fusing control have passed
operation temperature 1 to printing operation temperature 2
Setting range
Initial setting
100 to 165 (°C)
135
160
160 to 220 (°C)
190
160 to 220 (°C)
195
1 to 99
5