Viewing The Abnormal <!> Display - Sony SRW-9000PL Operation Manual

Hdcam sr format digital cinematography camcorder
Hide thumbs Also See for SRW-9000PL:
Table of Contents

Advertisement

<VF DISPLAY> page
Item
Setting
FPS
Set to ON to obtain the frame rate
indication 1.
FOCUS
Set to ON to display the focus position
indication 4.
IRIS
Set to ON to display the F value
indication qd.
ZOOM
Set to ON to display the zoom position
indication 5.
ND
Set to ON to display the optical filter
indications 8.
5600K
Set to ON to display the 5600
indication 7.
WHITE
Set to ON to display the white balance
memory indication 6.
GAIN
Set to ON to display the gain value
indication 9.
SHUTT
Set to ON to display the shutter
indication 0.
UNIT
Select the unit for the shutter
indication.
deg: Shutter angle (default)
sec: Shutter speed (sec)
BATT
Set to ON to display the battery
indication 3.
REC
Set to ON to display the recording
mode indication 2.
TAPE
Set to ON to display the tape remaining
indication qs.
TC
Set to ON to display the timecode
indication qh.
AUDIO
Set to ON to display the audio level
meters qa.
MESSAG Select the type of messages to be
displayed in the message area qg.
ALL: Display all messages
AT: Display auto setup information and
higher
WRN: Display warning messages and
higher
OFF: Display warning messages of the
highest level only
64
Viewing Settings and Indications in the Viewfinder
Viewing the ABNORMAL <!>
Display
An ABNORMAL< ! > screen like the one shown
below appears if you press the CANCEL/
STATUS button when the basic status indications
are displayed in the viewfinder.
This screen allows you to check for items that are
set to non-standard settings.
You can select the items to display and define
non-standard settings on the <'!' IND> page of
the Camera >USER (OPERATION) menu.
Setting the ABNORMAL<!> indications
<'!' IND> page
For each item, select ON in the [IND] column if
you want that item to appear in the
ABNORMAL<'!'> screen.
Specify the standard setting in the [NORMAL]
column.
When an item is set to select ON in the [IND]
column, and the setting is other than the setting
specified in the [NORMAL] column, that
condition is indicated in the ABNORMAL<'!'>
screen.
Item
Setting
ND
ND filter selection: 1, 2, 3, 4, 5
(combination allowed)
WHITE
White balance memory selection: P,
A, B (combination allowed)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hksr-9001Hksr-9002

Table of Contents