Character Data On And Off; Assigning Functions To Assignable Buttons/Switch - Sony SRW-9000PL Operation Manual

Hdcam sr format digital cinematography camcorder
Hide thumbs Also See for SRW-9000PL:
Table of Contents

Advertisement

Setting
Operation of the fans
AUTO2
Normally the fans are
controlled in the same way as
in MIN mode, but during
recording they are controlled
for quieter operation.
However, control for quieter
operation is limited to several
minutes or less.
Use this mode only when the
ambient temperature is normal
or lower.
MIN
In this mode, the fans operate
quietly regardless of whether
the unit is recording. This
mode is preferable for 30
minutes or more of shooting
in quiet environments such as
concert halls.
Use this mode only when the
ambient temperature is normal
or lower.
MAX
The fans rotate at maximum
speed to lower the unit's
internal temperature.
Notes
• If the internal temperature rises so high that the
TEMPERATURE CARE message is displayed, the
fan rotation speed will automatically increase to lower
the temperature.
• If the internal temperature rises so high that the TEMP
WARNING/FAN MAX message appears, the fan
mode changes automatically to MAX. After the
temperature has dropped sufficiently and the message
has disappeared, restore the original mode manually.
• When the video format is 50P, the fans are controlled
as in AUTO1 mode, even when AUTO2 or MIN mode
is selected, so that the higher power consumption does
not lead to higher internal temperatures. Also, the fans
do not operate more quietly during recording.
To change the fan mode from a menu
You can also change the fan mode by using FAN
MODE on the <OTHERS 1> page of the Camera
>USER (MAINTENANCE) menu (see
page 144).

Character Data On and Off

You can enable and disable the superimposition
of character data onto the camera picture for
selected output destinations.
Character data page
Superimposition of character data can be turned
ON or OFF for each of the following destinations
individually.
VF
The viewfinder connected to the VF connector
(default ON)
HDY
A monitor connected to the TEST OUT or
REMOTE connector. This setting is enabled
when TEST[SIG] or RM[SIG] has been set to
HD-Y in the <MONITOR OUTPUT> page of the
Camera >USER (OPERATION) menu (default
ON).
MON
A monitor connected to the HD SDI MON1 or
HD SDI MON2 connector (default ON)
VBS
A monitor connected to the TEST OUT or
REMOTE connector (default ON)
Assigning Functions to
Assignable Buttons/Switch
You can assign functions to the following
buttons/switch: assignable buttons 1 to 3 and 5 to
8 on the right-side panel of the main unit and the
AP-1 (optional); the 4 side (top) of the assignable
4/AUTO BLK BAL switch (called "switch 4"
below) and assignable buttons N and C.
The following functions are assigned when the
unit is shipped from the factory.
Switch
Function
1
OFF (no function)
2
OFF (no function)
3
OFF (no function)
4
OFF (no function)
5
STOP
6
PLAY
7
REW
8
F.FWD
N
OFF (no function)
C
OFF (no function)
Basic Settings with the Subdisplay
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hksr-9001Hksr-9002

Table of Contents