INTAKE AND EXHAUST - Air Cleaner
Air intake hose A
Air intake hose B
INSTALLATION SERVICE POINTS
AIR INTAKE HOSE A, TURBOCHARGER
BY-PASS VALVE AND AIR BY-PASS HOSE
INSTALLATION
Engaging the notch with the A mark at points indicated by
the arrows, insert air intake hoses B and C until seated.
Insert the turbocharger end of air intake hoses B and C com-
pletely.
INSPECTION
Check the air cleaner body, cover or packing for deforma-
l
tion, corrosion or damage.
Check the air duct for damage.
l
Check the air cleaner element for clogging, contamination
l
or damage.
If element is slightly clogged, remove dust by blowing
air from inside of element.
VOLUME AIR FLOW SENSOR CHECK
For inspection of volume airflow sensor, refer to GROUP 13A