2.2 Space Requirements

IP Office control units and modules are designed to be installed either in a free-standing stack or into a 19" rack system.
Rack installation requires a
If being used without any external expansion modules, the IP500 and IP500 V2 control units can be wall mounted using a
wall mounting kit.
· Cable Clearance
Clearance must be provided at the front and rear of all modules for cable access and feature key dongle connection.
Allow a minimum clearance of 90mm (3.5 inches).
· Additional Clearance
Care should be taken to ensure that the positioning of the modules does not interrupt air flow and other factors that
may affect
environmental
have ventilation slots at the side.
· Cable Access
Power cords must not be attached to the building surface or run through walls, ceilings, floors and similar openings.
Installation measures must be taken to prevent physical damage to the power supply cord, including proper routing
of the power supply cord and provision of a socket outlet near the fixed equipment or positioning of the equipment
near a socket outlet.
PARTNER Version Installation Manual
IP Office Essential Edition
rack mounting kit
for each control unit and expansion module.
requirements. This is especially important on IP500 and IP500 V2 control units which
Installation Requirements: Environmental Requirements
Page 27
- Issue 1c (09 April 2010)