1.11.2 Analog Phone Barrier Box

Where analog phone extensions are required in another building, additional protective equipment must be used, in the
form of IP Office Phone Barrier Boxes and protective earth connections.
· The correct IP Office specific barrier boxes must be used. These modules have been designed specifically for the
signalling voltages used by the IP Office Essential Edition - PARTNER® Version system:
· Only the IP Office Phone Barrier Box V2 should be used.
· No other type of analog phone barrier box should be used.
· Where more than 3 barrier boxes are required in a building, they must be rack mounted using a
mounting
kit.
· A maximum of 16 barrier boxes can be used with any Phone module.
· CAUTION: PHONE (POT) ports on the front of control units must not be used for extensions that are external to the
main building.
Main Building
· RJ11: Connect to PHONE (POT) port on the
Phone module using cable supplied with the
barrier box.
· RJ45: Connect to the secondary building
barrier box via primary protection in both
buildings.
· Center Screw: Connect to main building
protective ground (or ground terminal of
Barrier Box Rack Mounting Kit). Use 18AWG
(minimum) wire with a green and yellow
sleeve.
· Right-Hand Screw: Connect to ground point
on Phone module using ground cable supplied
with barrier box.
Wires from external telephone going directly to the barrier boxes must be kept apart, that is not routed in the same
bundle:
IP Office Barrier Boxes
PARTNER Version Installation Manual
IP Office Essential Edition
IP Office 500 Phone Barrier Box (81V)
Use with Phone V1 module. Includes an RJ45 to RJ11 cable and a
functional earth lead.
IP Office 500 Phone Barrier Box V2 (101V)
Use with Phone V2 module. Includes an RJ45 to RJ11 cable and a
functional earth lead.
Barrier Box Rack Mounting Kit
System Overview: Out of Building Connections
Barrier Box
Secondary Building
· RJ11: Connect to analog phone.
Cable not supplied.
· RJ45: From main building via primary
protection in both buildings.
· Center Screw: Connect to main
building protective ground. Use
18AWG (minimum) wire with a green
and yellow sleeve.
· Right-Hand Screw: Not used.
Barrier Box rack
Part number
700293897
700385495
700293905
Page 23