7.4.1 Analog Trunk Card
This card can be added to an IP500 base card to provide that card with support for 4 loop-start analog trunks.
Name
IPO 500 Trnk Anlg 4 Uni IP Office 500 Trunk Card Analog 4 Universal
PARTNER Version Installation Manual
IP Office Essential Edition
· Ports/Channels
4 Loop-start analog trunk ports. Connections via the host IP500 base card.
· DTMF, ICLID, Busy tone detection.
· Over-voltage and lightning protection (may still require additional
protection equipment see
Connections.
· DTMF and LD dialing.
· Adjustable echo cancellation (default 16ms). Selectable to Off, 8, 16, 32,
64 and 128 milliseconds.
· Power Failure Port
Regardless of the IP500 card hosting it, during power failure pins 4 and 5
of port 12 are connected to pins 7 and 8. In addition, when fitted to an
IP500 Analog Phone 8 base card, during power failure extension port 8 is
connected to the analog trunk port 12.
· Maximum: 3.
Daughter Card Ports (9-12)
The LEDs for ports 9 to 12 of the IP500 base card are used as follows:
· Green on: Card fitted.
· Green flashing: Trunk in use.
· LED 9 is used for daughter card status.
· Red On = Error
· Red Slow Flash = Initializing.
· Red Flash every 5 seconds = Card okay.
· Red Fast Flash = System shutdown.
Description
System Component Details: Trunk Cards
Lightning Protection/Out-of-Building
SAP Code
700417405
Page 107
- Issue 1c (09 April 2010)