Concluding Steps; Replacing A 3.5-Inch Hdd Module - Fujitsu PRIMERGY TX1320 M1 Upgrade And Maintenance Manual

Servers
Hide thumbs Also See for PRIMERGY TX1320 M1:
Table of Contents

Advertisement

7.3.3.3

Concluding steps

Perform the following procedures to complete the task:
Ê Close the front cage as described in section
page
62.
Ê Close the server cover as described in section
on page
66.
7.3.4

Replacing a 3.5-inch HDD module

Upgrade and Repair Unit
(URU)
Tools: tool-less
V
CAUTION!
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "FUJITSU Server PRIMERGY
TX1320 M1 Operating Manual".
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
TX1320 M1
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
"Closing the front cage" on
"Mounting the server cover"
Hardware: 10 minutes
137