Hard disk drives / solid state drives
7.2.4
Replacing a 2.5-inch HDD / SSD module
Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD / SSD module during operation if the drive is
●
not currently being accessed. Observe the indicators for the
corresponding HDD / SSD modules, see "FUJITSU Server
PRIMERGY TX1320 M1 Operating Manual".
Under no circumstances should you remove an HDD / SSD module
●
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.4.1
Preliminary steps
Before replacing a 2.5-inch HDD / SSD module, perform the following steps:
Ê Remove the hard disk drive cover as described in section
hard disk drive cover" on page
Ê Locate the defective server as described in section
server" on page
Ê Locate the defective HDD / SSD module as described in section
diagnostic indicators on the front" on page
Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
126
59.
44.
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Removing the
"Locating the defective
48.
"Local
TX1320 M1