Hard disk drives / solid state drives
7.2.4

Replacing a 2.5-inch HDD / SSD module

Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators for the
corresponding HDD / SSD modules, see "FUJITSU Server
PRIMERGY TX1320 M1 Operating Manual".
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.4.1

Preliminary steps

Before replacing a 2.5-inch HDD / SSD module, perform the following steps:
Ê Remove the hard disk drive cover as described in section
hard disk drive cover" on page
Ê Locate the defective server as described in section
server" on page
Ê Locate the defective HDD / SSD module as described in section
diagnostic indicators on the front" on page
Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
126
59.
44.
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Removing the
"Locating the defective
48.