Minimum Startup Configuration - Fujitsu PRIMERGY TX1320 M1 Upgrade And Maintenance Manual

Servers
Hide thumbs Also See for PRIMERGY TX1320 M1:
Table of Contents

Advertisement

16.4

Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
Power supply unit
Table 7: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 8: Minimum startup configuration - cables
Ê Shut down the server as described in section
page
52.
Ê Remove the AC power cord from the cable tie and disconnect it from the
system as described in section
Ê Take the system down to its minimum startup configuration.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section
page
67.
TX1320 M1
Notes and reference
no TPM, UFM or expansion cards installed
no fan (disconnect fan cable)
installed in DIMM slot 1A, see section
"Memory sequence" on page 217
Notes and reference
"Disconnecting power cords" on page
"Connecting the server to the mains" on
Upgrade and Maintenance Manual
"Shutting down the server" on
Appendix
53.
339