806f090c-2b81000e • 806f090c-2b81000f
806f090c-2b81000e
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: IMM determined DIMM 14 in Compute Book 1 has been throttled due to high temperature.
May also be shown as 806f090c2b81000e or 0x806f090c2b81000e
Severity: Warning
Alert Category: System - Other
Serviceable: yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: no
User response: Complete the following steps until problem is solved:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Check IBM Support site for Service Bulletins/RETAIN tips related to an throttled DIMM Condition.
5. If eXFlash DIMM, make sure the eXFlash DIMM FW is updated to the latest level.
6. If the DIMM problem persists and there are no other DIMMs with the same indication, replace the DIMM.
7. If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication, confirm
that the eXFlash DIMM is under warranty before replacement.
Related Links:
"Server features and specifications" on page 7
v
"Removing a DDR3 compute book" on page 283
v
"Replacing a DDR3 compute book" on page 284
v
"Removing the DDR3 compute book cover" on page 218
v
"Replacing the DDR3 compute book cover" on page 220
v
"Removing a memory module" on page 239
v
"Replacing a memory module" on page 240
v
v
"Flash DIMMs" on page 51
806f090c-2b81000f
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: IMM determined DIMM 15 in Compute Book 1 has been throttled due to high temperature.
May also be shown as 806f090c2b81000f or 0x806f090c2b81000f
Severity: Warning
Alert Category: System - Other
Serviceable: yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: no
User response: Complete the following steps until problem is solved:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Check IBM Support site for Service Bulletins/RETAIN tips related to an throttled DIMM Condition.