COMP FUNCTION screen

1.
Access the COMP screen for the desired channel.
2.
Press [FUNC] to access the COMP FUNCTION screen.
The operations available at the CHANNEL FUNCTION screen are
as follows:
TYPE SELECT
This selects COMPRESSOR or LIMITER as the
compressor type. (LIMITER cannot be selected for
CH1-32.)
AUTO GAIN
This turns AUTO GAIN on/off.
KEY-IN SOURCE
This button accesses the KEY-IN SELECT screen for
selecting the key-in signal. For stereo-linked
channels, L and R sources are shown.
This is not displayed for AUX, MTX, or MAIN (p. 37).
KEY-IN FILTER
This accesses the COMP KEY-IN FILTER screen. This is
not displayed for AUX, MTX, or MAIN (p. 51).
COPY
Copies compressor settings to the clipboard.
PASTE
When compressor settings have been copied to the
clipboard, this pastes the settings from the
clipboard.
UNDO
This undoes the last-performed parameter paste
operation. It is not displayed when there is no action
to undo.
LIBRARY
Accesses the COMP LIBRARY screen.
PEAK CLEAR
Clears the level meter's peak hold or over indication.
For information on, COPY, PASTE, UNDO, LIBRARY, or PEAK
CLEAR, go to "Basic operation," and refer to "Copy" (p. 28),
"Paste" (p. 29), "Undo" (p. 29), "Library" (p. 30), or "Peak clear" (p.
33).
For information on TYPE SELECT, refer to "Changing between
COMPRESSOR/LIMITER" (p. 52).
If you turn AUTO GAIN on, the output response of the
compressor is boosted as high as possible while maintaining 6
dB of headroom.
COMPRESSOR/LIMITER screen
The compressor will narrow the dynamic range, because it
reduces the output of incoming signals that exceed the
threshold level.
If AUTO GAIN is on, the upper limit of the output level
when ATTACK time is 0 ms is boosted while maintaining 6
dB of headroom from clip level (0 dB), thus maximizing the
dynamic range.
The 6 dB of headroom is maintained to prevent the
compressor's output from clipping during the attack
portion of the input signal when the ATTACK time is set to
a longer value.
Selecting the key-in signal
The key-in signal used by the compressor is taken from the post-
gate point of the channel itself or from any of the following
sources:
• CH1-32 direct out
• AUX1-8, MTX1-4, or MAIN L/R output
• REAC INPUT1-40
• INPUT1-24
ATT
HPF
- SELF POST GATE
- CH 1-32 DIRECT OUT
- MAIN L / R
- AUX 1–8
- MTX 1–4
- INPUT 1–24
- DOCK INPUT L / R
- REAC INPUT1–40
You use the COMP KEY-IN SOURCE screen to select the key-in
signal.
No key-in function is available for compressors on AUX1-8,
MTX1-4, or MAIN L or R.
1.
Access the COMP FUNCTION screen.
2.
Select "KEY-IN SOURCE" and press [ENTER] to access the
COMP KEY-IN SOURCE screen.
3.
Use the value dial to move to the desired channel and
press [ENTER] to select the channel to use as the key-in
signal.
GATE/
COMP
EXP
KEY-IN
KEY-IN
SOLO
KEY-IN
TO SOLO
FILTER