GATE FUNCTION screen

1.
Access the GATE/EXPANDER screen for the desired
channel.
2.
Press [FUNC] to access the GATE FUNCTION screen.
The operations available at the GATE FUNCTION screen are as
follows:
TYPE SELECT
This selects the type of gate from among the three
types of GATE, EXPANDER, and DUCKING (p. 45).
KEY-IN SOURCE
This button accesses the KEY-IN SELECT screen for
selecting the key-in signal. For stereo-linked
channels, L and R sources are shown (p. 37).
KEY-IN FILTER
This button accesses the GATE KEY-IN FILTER screen
(p. 48).
COPY
Copies gate settings to the clipboard.
PASTE
When gate settings have been copied to the
clipboard, this pastes the settings from the
clipboard.
UNDO
This undoes the last-performed parameter paste
operation. It is not displayed when there is no action
to undo.
LIBRARY
Accesses the GATE LIBRARY screen.
PEAK CLEAR
Clears the level meter's peak hold or over indication.
For information on, COPY, PASTE, UNDO, LIBRARY, or PEAK
CLEAR, go to "Basic operation," and refer to "Copy" (p. 28),
"Paste" (p. 29), "Undo" (p. 29), "Library" (p. 30), or "Peak clear" (p.
33).
GATE/EXPANDER screen
Selecting the type of GATE/EXPANDER
1.
Access the GATE FUNCTION screen.
2.
Select "TYPE SELECT" and press [ENTER].
GATE TYPE SELECT screen appears.
3.
Select GATE, EXPANDER, or DUCKING as the GATE type,
and press [ENTER].
The type changes.