Configuration Manual
Ascom d62 DECT Handset
Configure Alarm Settings Group (sub group)
1
Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X.
2
In the Name of group field, enter a descriptive name.
3
Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X > Common.
• Stored alarm data - Information that shall be sent along an alarm (for example a
handset´s location)
• Indicate triggered alarm with LED
• Indicate triggered alarm with vibrator
• Indicate triggered alarm with beeper signal
NOTE: If any of the alarm triggers are set to "No", no indication is shown for that
trigger when an alarm is sent or received.
4
Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X > Alarm on long press
• Alarm type for long press - Determines the alarm type to be sent when long
pressing the alarm button. If Not used is selected, the call can still be dialed after
alarm number (if any, see
sending an alarm.
• ALS - Determines if a ramped up signal shall sound after an alarm is sent. Note: If
the handset is configured to call a predefined number when an alarm is sent (see
5.24 Common Alarm Settings
5
Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X > Alarm on multiple press
• Alarm type for multiple press - Determines the alarm type to be sent when
pressing the alarm button twice or more. If Not used is selected, the call can still
be dialed after alarm number (if any, see
34) without sending an alarm.
• ALS - Determines if a ramped up signal shall sound after an alarm is sent. Note: If
the handset is configured to call a predefined number when an alarm is sent (see
5.24 Common Alarm Settings
Configure Sound and Alerts Sub Group
These parameters let the system administrator define up to five different system profile sub
groups of sounds and alerts. To configure a sub group:
1
Select System Profiles > System Profiles Sub Groups > Sound and Alerts group >
Sound and alerts X.
2
In the Name of group field, either accept the default name Group X or enter a
description appropriate to this particular sub group of sounds and alerts.
3
From the pull down menus associated with each parameter, select the required
values for:
Ring volume: Select "Silent" or one of the volume levels between 1, the lowest, and 8,
the highest.
Vibrating alert: Select "On" or "Off".
Internal call: A ringtone to indicate an internal call.
External call: A ringtone to indicate an external calls.
Callback: A ringtone to indicate a callback.
PTT Call: A ringtone to indicate a Push-to-talk call.
Key sound: Select "Silent" or associate the key press with a "Click" or "Tone".